Lina Gundelwein

Lina Gundelwein

Auto-generated profile, based on publicly available information

Lina Gundelwein

1000shapes GmbH, Berlin, Germany

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2021 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
PYPavlo Yevtushenko
Pavlo Yevtushenko
LGLeonid Goubergrits
Leonid Goubergrits
LGLina Gundelwein
Lina Gundelwein
ASArnaud Setio
Arnaud Setio
HRHeiko Ramm
Heiko Ramm
MSMarie Schafstedde
Marie Schafstedde
Image-based patient-specific modelling of hemodynamics are gaining increased popularity as a diagnosis and outcome prediction solution for a variety of cardiovascular diseases. While their potential to improve diagnostic capabilities and thereby clinical outcome is widely recognized, these methods require considerable computational resources since they are mostly based on conventional numerical methods such as computational fluid dynamics (CFD). As an alternative to the numerical methods, we propose a machine learning (ML) based approach to calculate patient-specific hemodynamic parameters. Compared to CFD based methods, our approach holds the benefit of being able to calculate a patient-specific hemodynamic outcome instantly with little need for computational power. In this proof-of-concept study, we present a deep artificial neural network (ANN) capable of computing hemodynamics for patients with aortic coarctation in a centerline aggregated (i.e., locally averaged) form. Considering the complex relation between vessels shape and hemodynamics on the one hand and the limited availability of suitable clinical data on the other, a sufficient accuracy of the ANN may however not be achieved with available data only. Another key aspect of this study is therefore the successful augmentation of available clinical data. Using a statistical shape model, additional training data was generated which substantially increased the ANN's accuracy, showcasing the ability of ML based methods to perform in-silico modelling tasks previously requiring resource intensive CFD simulations.

5 February 2021 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
BTB. Thamsen
B. Thamsen
PYP. Yevtushenko
P. Yevtushenko
LGL. Gundelwein
L. Gundelwein
ASA. A. A. Setio
A. A. A. Setio
HLH. Lamecker
H. Lamecker
LGLeonid Goubergrits
Leonid Goubergrits
Modeling of hemodynamics and artificial intelligence have great potential to support clinical diagnosis and decision making. While hemodynamics modeling is extremely time- and resource-consuming, machine learning (ML) typically requires large training data that are often unavailable. The aim of this study was to develop and evaluate a novel methodology generating a large database of synthetic cases with characteristics similar to clinical cohorts of patients with coarctation of the aorta (CoA), a congenital heart disease associated with abnormal hemodynamics. Synthetic data allows use of ML approaches to investigate aortic morphometric pathology and its influence on hemodynamics. Magnetic resonance imaging data (154 patients as well as of healthy subjects) of aortic shape and flow were used to statistically characterize the clinical cohort. The methodology generating the synthetic cohort combined statistical shape modeling of aortic morphometry and aorta inlet flow fields and numerical flow simulations. Hierarchical clustering and non-linear regression analysis were successfully used to investigate the relationship between morphometry and hemodynamics and to demonstrate credibility of the synthetic cohort by comparison with a clinical cohort. A database of 2652 synthetic cases with realistic shape and hemodynamic properties was generated. Three shape clusters and respective differences in hemodynamics were identified. The novel model predicts the CoA pressure gradient with a root mean square error of 4.6 mmHg. In conclusion, synthetic data for anatomy and hemodynamics is a suitable means to address the lack of large datasets and provide a powerful basis for ML to gain new insights into cardiovascular diseases.

4 September 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MWMartin Würtz
Martin Würtz
DADennis Aumiller
Dennis Aumiller
LGLina Gundelwein
Lina Gundelwein
PJPhilipp Jung
Philipp Jung
CSChristian Schütz
Christian Schütz
KRKarl Rohr
Karl Rohr
DNA compaction and accessibility in eukaryotes are governed by nucleosomes and orchestrated through interactions between DNA and DNA-binding proteins. Using QuantAFM, a method for automated image analysis of atomic force microscopy (AFM) data, we performed a detailed statistical analysis of structural properties of mono-nucleosomes. QuantAFM allows fast analysis of AFM images, including image preprocessing, object segmentation, and quantification of different structural parameters to assess DNA accessibility of nucleosomes. A comparison of nucleosomes reconstituted with and without linker histone H1 quantified H1’s already described ability of compacting the nucleosome. We further employed nucleosomes bearing two charge-modifying mutations at position R81 and R88 in histone H2A (H2A R81E/R88E) to characterize DNA accessibility under destabilizing conditions. Upon H2A mutation, even in presence of H1, the DNA opening angle at the entry/exit site was increased and the DNA wrapping length around the histone core was reduced. Interestingly, a distinct opening of the less bendable DNA side was observed upon H2A mutation, indicating an enhancement of the intrinsic asymmetry of the Widom-601 nucleosomes. This study validates AFM as a technique to investigate structural parameters of nucleosomes and highlights how the DNA sequence, together with nucleosome modifications, can influence the DNA accessibility.