This paper examines the effect of building shape, zones, orientation and window to wall ratio (WWR) on the lighting energy requirement and the thermal comfort in the naturally ventilated houses in tropical climate. The lighting electricity and the adaptive thermal discomfort hours (ASHRAE 55 80% acceptability) of 300 different models of two-storey houses were obtained using Design Builder simulation software. The models were developed for three building shapes (square, rectangle and L-shaped) and the orientation of each model was changed for 24 orientations and four window to wall ratios. Results indicate that the rectangular shape with staircase positioned in the middle of the house will provide higher thermal comfort for WWR of 20 and for other WWRs the L-shaped models provide higher thermal comfort when the staircase is positioned at the short corner or middle. The square-shaped houses with staircase at the middle have the highest lighting electricity and the L shape has the lowest lighting electricity. Further, WWR changes the thermal comfort by 20–55% and the percentage change in lighting electricity due to WWR is only 1.5–9.5%. Therefore, thermal comfort should receive more attention in deciding the WWR. Moreover, the results show an effect when the zone sizes and location change.
1 January 2010 in Journal of Rehabilitation Research and Development
The mechanical properties of human foot tissue in vivo as well as discomfort and pain thresholds are important for various applications. In this study, an apparatus for measuring the discomfort and pain thresholds and the mechanical properties of human tissues is presented. The apparatus employs a stepper motor that controls the indentation speed, as well as a load cell and potentiometer that determine the corresponding reaction force and tissue deformation (displacement), respectively. A LabVIEW program (LabVIEW 8, National Instruments Corporation; Austin, Texas) was developed to control the indentation via a data acquisition card. The apparatus can accommodate indentor displacements up to 35 mm and can impart forces up to 150 N at a controlled indentation speed in the range of 0 to 10 mm/s. Tests showed that the displacement measurement error is <0.17 mm in the nominal range (0.5% in the full scale) and the measurement error of force is <1.6 N in the nominal range (1.1% in the full scale). Experimental results indicate that the apparatus is reliable and flexible for measuring the mechanical properties of foot tissue in vivo in conjunction with pain and discomfort thresholds.
The optimal force distribution to minimise pain or discomfort at the foot–shoe interface is still not known. Most shoe-related products attempt to distribute the load uniformly without much consideration to the bony and soft tissue regions. An experiment was conducted to first determine the pressure pain threshold (PPT) and tissue deformation on the plantar surface of the foot. Circular probes of areas 0.5, 1.0 and 2.0 cm2 at indentation speeds of 0.5, 1 and 2 mm/s showed that PPT depends on the location stimulated, area of stimulation and the indentation speed. The results also showed that tissue stiffness is quite low for small deformations ( < 4 mm), but significantly higher at large deformations (>4 mm). The stiffness at the larger deformation region was positively correlated with PPT (r = 0.63, p < 0.001). The data were further used to develop a model with PPT, deformation and stimulated area. Practitioner Summary: Pressure at which there is an onset of pain is higher when a larger area of soft tissue is stimulated. Bony areas may be better suited to bear load on smaller areas to minimise pressure-related pain. Thus, manipulating supporting surface stiffness and surface contours can help minimise pain.
The rapid increase of the grid-connected solar photovoltaic (PV) has been reported to make a considerable impact on the power quality (PQ) in the grid. This paper discusses the generation and propagation of significant current/voltage harmonics which are caused by PV inverters in distribution networks. The impact made by high switching frequencies and different operating scenarios are studied by detailed modelling of PV inverters in a typical low voltage (LV) distribution network using PSCAD/EMTDC simulation platform. It was found that the PV inverter systems inject high frequency current harmonics at the switching frequency or associated side bands. Low order current harmonics are also significant due to the inability of switching control system of PV inverter to produce perfectly sinusoidal output. It is found that the amount of harmonics depend on the inverter control strategy, background distortion present at the point of connection (POC) and the percentage of inverter loading. Further, harmonic voltage distortion is found to be mainly dependent on the impedance of the distribution network where weak networks lead to give rise to higher voltage distortions. Moreover, harmonic resonances are significant due to the interaction of the inverter output impedance and the grid inductance. The current harmonics injected by single phase inverters have been found substantial and influential with regard to the energy transmission and increase losses.