21 July 2021 in NMR in Biomedicine
26 March 2024 in IEEE Transactions on Biomedical Engineering
Magnetic resonance elastography (MRE) of brain relies on inducing and measuring shear waves in the brain. However, studies have shown vibration could induce changes in cerebral blood flow (CBF), which has a modulation effect and can affect the biomechanical properties measured. Objective: This work demonstrates the initial prototype of the indirect excitation method, which can generate shear waves in the brain with minimal changes in CBF. Methods : A simple system was designed to produce stable vibrations underneath the neck. Instead of directly stimulating the skull, shear waves were indirectly transmitted to the brain through the spine and brainstem. Results : Phantom results showed that the proposed actuator did not interfere with the routine imaging sequence and successfully generated multifrequency shear waves. When compared with the conventional direct head stimulation method, brain MRE results from the proposed actuator showed no significant differences in terms of intraclass correlation coefficients (ICC) and coefficients of variation (CV). Moreover, the octahedral shear strain (OSS) generated by the indirect excitation in the frontal and parietal lobes decreased by 25.96% and 16.73% respectively. Evaluation of CBF in healthy volunteers revealed no significant changes for the indirect excitation method, whereas significant decreases in CBF were observed in four subregions when employing direct excitation. Conclusion : The proposed actuator offers a more accurate and comfortable approach to MRE measurements while causing minimal CBF alterations. Significance : This work presents the first demonstration of an indirect excitation brain MRE system that minimizes CBF changes, thus holding potential for future applications of brain MRE.
6 March 2024 in Journal of Magnetic Resonance Imaging
Background: Different MR elastography (MRE) systems may produce different stiffness measurements, making direct comparison difficult in multi‐center investigations.Purpose: To assess the repeatability and reproducibility of liver stiffness measured by three typical MRE systems.Study Type: Prospective.Population/Phantoms: Thirty volunteers without liver disease history (20 males, aged 21–28)/5 gel phantoms.Field Strength/Sequence: 3.0 T United Imaging Healthcare (UIH), 1.5 T Siemens Healthcare, 3.0 T General Electric Healthcare (GE)/Echo planar imaging‐based MRE sequence.Assessment: Wave images of volunteers and phantoms were acquired by three MRE systems. Tissue stiffness was evaluated by two observers, while phantom stiffness was assessed automatically by code. The reproducibility across three MRE systems was quantified based on the mean stiffness of each volunteer and phantom.Statistical Tests: Intraclass correlation coefficients (ICC), coefficients of variation (CV), and Bland–Altman analyses were used to assess the interobserver reproducibility, the interscan repeatability, and the intersystem reproducibility. Paired t‐tests were performed to assess the interobserver and interscan variation. Friedman tests with Dunn's multiple comparison correction were performed to assess the intersystem variation. P values less than 0.05 indicated significant difference.Results: The reproducibility of stiffness measured by the two observers demonstrated consistency with ICC > 0.92, CV < 4.32%, Mean bias < 2.23%, and P > 0.06. The repeatability of measurements obtained using the electromagnetic system for the liver revealed ICC > 0.96, CV < 3.86%, Mean bias < 0.19%, P > 0.90. When considering the range of reproducibility across the three systems for liver evaluations, results ranged with ICCs from 0.70 to 0.87, CVs from 6.46% to 10.99%, and Mean biases between 1.89% and 6.30%. Phantom studies showed similar results. The values of measured stiffness differed across all three systems significantly.Data Conclusion: Liver stiffness values measured from different MRE systems can be different, but the measurements across the three MRE systems produced consistent results with excellent reproducibility.Evidence Level: 1Technical Efficacy: Stage 2