José Antonio Becerra

José Antonio Becerra

Auto-generated profile, based on publicly available information

José Antonio Becerra

Departamento Ingeniería Energética, Universidad de Sevilla, Camino de los Descubrimientos S/N, 41092 Sevilla, Spain

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2016 in Applied Energy
Verified
Journal Article
Open access
FSFundación Investigación de Sevilla
Fundación Investigación de Sevilla
AAA. Alovisio
A. Alovisio
COCarlos Ortíz
Carlos Ortíz
JMJosè Manuel Valverde Millan
Josè Manuel Valverde Millan
VVV. Verda
V. Verda
JBJ.A. Becerra
J.A. Becerra
Energy storage is the main challenge for a deep penetration of renewable energies into the grid to overcome their intrinsic variability. Thus, the commercial expansion of renewable energy, particularly wind and solar, at large scale depends crucially on the development of cheap, efficient and non-toxic energy storage systems enabling to supply more flexibility to the grid. The Ca-Looping (CaL) process, based upon the reversible carbonation/calcination of CaO, is one of the most promising technologies for thermochemical energy storage (TCES), which offers a high potential for the long-term storage of energy with relatively small storage volume. This manuscript explores the use of the CaL process to store Concentrated Solar Power (CSP). A CSP-CaL integration scheme is proposed mainly characterized by the use of a CO2 closed loop for the CaL cycle and power production, which provides heat decoupled from the solar source and temperatures well above the 550 C limit that poses the use of molten salts currently used to store energy as sensible heat. The proposed CSP-CaL integration leads to high values of plant global efficiency (of around 45-46%) with a storage capacity that allows for long time gaps between load and discharge. Moreover, the use of environmentally benign, abundantly available and cheap raw materials such as natural limestone would mark a milestone on the road towards the industrial competitiveness of CSP

1 October 2017 in Energy Conversion and Management
Verified
Journal Article
Closed access
COC. Ortiz
C. Ortiz
FSFundación Investigación de Sevilla
Fundación Investigación de Sevilla
JVJ.M. Valverde
J.M. Valverde
AAA. Alovisio
A. Alovisio
JBJ.A. Becerra
J.A. Becerra

1 October 2016 in Materials & Design
Verified
Journal Article
Closed access
AGAurora Gomez-Martin
Aurora Gomez-Martin
MOM.P. Orihuela
M.P. Orihuela
JBJ.A. Becerra
J.A. Becerra
JMJ. Martínez-Fernández
J. Martínez-Fernández
JRJoaquin Ramirez-Rico
Joaquin Ramirez-Rico

1 October 2016 in Energy Conversion and Management
Verified
Journal Article
Open access
FSFundación Investigación de Sevilla
Fundación Investigación de Sevilla
LVLeo Vigna
Leo Vigna
JBJ.A. Becerra
J.A. Becerra
VVV. Verda
V. Verda
Among the concentrated solar power technologies, those based on Organic Rankine Cycles have a very low market presence. However they have favorable characteristics for applications with low temperature and small/medium size (<10 MW), such as off-grid applications or distributed power generation. In this paper is analyzed a 5MW parabolic trough plant integrated with an Organic Rankine cycle power block and thermal storage. On this purpose, two different thermal storage integrations are analyzed. They are based on two different heat storage layouts: direct system using Hitec XL both as Heat Transfer Fluid and as storage medium; indirect system using Therminol VP-1 as Heat Transfer Fluid and Hitec XL as storage medium. Full system performance at rated and off-design conditions is presented operating with different organic working fluids. Its potential application and main challenges for its development are discussed in terms of performance and costs. Among the analyzed working fluids, the best results were obtained for the cycle working with Toluene with an efficiency at the power block of 31.5% and an estimated power block cost of 825 €/kW. The indirect storage layout was the most interesting from the point of view of Levelized Electricity Cost (16.19 c€/kW) and productivity (28.2 GW h/y for a 5 MWel plant) for 10 h of storage However, it results in a storage tanks volume 26% greater than the obtained for the equivalent direct storage layout. The results show the competitiveness and the potential of the proposed integrated small size parabolic trough designs for isolated applications as mines or for some distributed generation uses where grid capacity is limited

1 September 2019 in Renewable Energy
Verified
Journal Article
Closed access
IGIrene Garcia-Saez
Irene Garcia-Saez
JMJuan Méndez
Juan Méndez
COCarlos Ortiz
Carlos Ortiz
DLDrazen Loncar
Drazen Loncar
JBJosé A. Becerra
José A. Becerra
FSFundación Investigación de Sevilla
Fundación Investigación de Sevilla

1 October 2009 in Engineering Failure Analysis
Verified
Journal Article
Closed access
FJFrancisco José Jiménez-Espadafor
Francisco José Jiménez-Espadafor
JVJ. Becerra Villanueva
J. Becerra Villanueva
MIGUEL TORRES GARCIAMIGUEL TORRES GARCIA
MIGUEL TORRES GARCIA