Christian Keller

Christian Keller

Auto-generated profile, based on publicly available information

Christian Keller

Department of Anesthesiology, Schulthess Klinik, Zurich, Switzerland

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 September 2017 in Strahlentherapie und Onkologie
Verified
Journal Article
Closed access
PDF file
SSSusanne Stera
Susanne Stera
PBPanagiotis Balermpas
Panagiotis Balermpas
MCMark K. H. Chan
Mark K. H. Chan
SHStefan Huttenlocher
Stefan Huttenlocher
SWStefan Wurster
Stefan Wurster
OBOliver Blanck
Oliver Blanck

1 June 1992 in JAMA Otolaryngology–Head & Neck Surgery
Verified
Journal Article
Closed access
PDF file
CKChristopher Keller
Christopher Keller
WEWallace Elliott
Wallace Elliott
RHRichard N. Hubbell
Richard N. Hubbell
• A case report of an endotracheal tube fire occurring during electrodissection tonsillectomy is presented. The authors believe that this incident occurred because a retrograde leak of ventilating gases around an uncuffed endotracheal tube during positive-pressure ventilation produced a high oxygen concentration in the mouth, allowing indirect ignition of the tube. In vitro testing supported this hypothesis. Ignition tests on polyvinylchloride endotracheal tubes using electrocautery in various oxygen concentrations were performed. As oxygen concentration increased, the endotracheal tube could be moved further from the cautery and still allow ignition of the tube. At 52% oxygen, with the cautery set at 25-W coagulation current, the endotracheal tube could not be ignited. Recommendations to prevent a recurrence of this incident are included. (Arch Otolaryngol Head Neck Surg.1992;118:643-645)

1 July 1999 in Anaesthesia
Verified
Journal Article
Open access
PDF file
JBJ. Brimacombe
J. Brimacombe
CKC. Keller
C. Keller
We conducted a randomised cross‐over study of 20 patients to test the hypothesis that oropharyngeal leak pressure and the fibreoptic view differ between the cuffed oropharyngeal airway and laryngeal mask airway in paralysed patients. We also tested the design premise that inflation of the cuffed oropharyngeal airway cuff elevates the epiglottis from the posterior pharyngeal wall. Both airways were inserted into each patient in random order. Oropharyngeal leak pressure and fibreoptic view were documented at zero volume and after each additional 10 ml up to the maximum recommended volume for each device. The laryngeal mask had a higher maximum (23 vs. 16 cmH 2 O, p = 0.03), minimum (9 vs. 2 cmH 2 O, p < 0.02) and overall (17 vs. 9 cmH 2 O, p < 0.001) oropharyngeal leak pressure compared with the cuffed oropharyngeal airway. The glottic inlet was visible more frequently with the laryngeal mask (96 vs. 39%, p < 0.0001). There was no elevation of the epiglottis from the posterior pharyngeal wall with the cuffed oropharyngeal airway. We conclude that the laryngeal mask forms a more effective seal and provides a better fibreoptic view of the glottic inlet than the cuffed oropharyngeal airway in paralysed patients. Inflation of the cuffed oropharyngeal airway cuff does not cause elevation of the epiglottis.

1 June 2010 in Resuscitation
Verified
Journal Article
Closed access
Peter PaalPeter Paal
Peter Paal
TNThomas Niederklapfer
Thomas Niederklapfer
CKChristian Keller
Christian Keller
AGAchim von Goedecke
Achim von Goedecke
GLGünter Luckner
Günter Luckner
VWVolker Wenzel
Volker Wenzel

17 August 2008 in Der Anaesthesist
Verified
Journal Article
Closed access
PDF file
Holger HerffHolger Herff
Holger Herff
Peter PaalPeter Paal
Peter Paal
KLK.H. Lindner
K.H. Lindner
AGA. von Goedecke
A. von Goedecke
CKC. Keller
C. Keller
VWV. Wenzel
V. Wenzel

1 December 2004 in Pediatric Anesthesia
Verified
Journal Article
Closed access
PDF file
CKChristian Keller
Christian Keller
JBJoseph Brimacombe
Joseph Brimacombe
AGAchim Goedecke
Achim Goedecke
PLPhilipp Lirk
Philipp Lirk