This research is focused on determining the dose rate calibration of beta irradiation source in the Risø brand TL/OSL-DA-20 model thermoluminescence (TL) and optically stimulated luminescence (OSL) reader device manufactured by DTU Physics which is an integral component of the Technical University of Denmark (DTU). The beta radiation source of this device comprises a pellet-shaped Strontium ceramic made from the 90Sr/90Y radionuclide, with a half-life of approximately 29.1 years. This investigation provides a thorough examination of reproducing equivalent dose levels by comparing reproduced OSL signals with the OSL signals of calibration quartz crystals which were previously exposed to a 5 Gy beta radiation emission. Throughout this process, dose durations and equivalent dose levels were analysed on optically stimulated luminescence signals. The collected OSL data aims to ensure the precise calibration of the radioactive source, contributing to reliable results in dosimetric measurements. This calibrated device is utilized in the Luminescence Laboratory co-run by the Physics Department and Nuclear Materials Research and Application Center of Selçuk University. The determined dose rate of the beta radiation source is found as 0.065 Gy/second.
31 December 2024 in Journal of Radioanalytical and Nuclear Chemistry
This study investigates the thermoluminescence (TL) properties of natural obsidian samples collected from the Aksaray region in Turkey. The obsidian samples were ground into powder and sieved into five particle size ranges between 63 and 500 μm. The grain size range of 63–125 μm was identified as the most suitable for TL measurements, as it produced a sharper and more intense peak in the dosimetric region of the spectrum. Subsequently, detailed analyses were conducted on the TL glow curves, reusability, dose response, and heating rate behavior of the selected sample. The effect of heating rate was tested over a range of 0.1°C–10°C/s, revealing an anomalous heating rate dependence. Kinetic analysis using the method identified multiple peaks, indicating the presence of various energy levels. TL curve deconvolution using the general order kinetics model yielded activation energies ranging from 0.82 to 1.68 eV and demonstrated a strong correlation between the experimental data and theoretical predictions.
20 October 2022 in Sakarya University Journal of Science
The mass and average neutron-proton ratio (N/Z) distributions of fragments from multifragmentation of excited projectile nuclei formed in heavy-ion collisions were reproduced theoretically. The experimental measurements in peripheral heavy-ion collisions of 124Sn + 124Sn and 112Sn + 112Sn at 1 GeV/nucleon were carried out with the Fragment Separator (FRS) of GSI. The mass distribution and N/Z ratios of the produced nuclear fragments are calculated in the frame of a statistical approach. Comparisons with the experimental data show that the statistical models are successfully reproduce the mass yields and N/Z measured in the both reaction systems. The calculations in the present paper were carried out for the first time and were not published anywhere else.
15 March 2026 in Black Sea Journal of Engineering and Science
In this study, thermoluminescence analyses were performed on natural CaCO₃ mineral sample obtained from Konya region after exposure to beta irradiation. Examining the thermoluminescence curve of the un-annealed sample, it was determined that there is a maximum at 100 °C and a tail extension around 250 °C. To detect the presence of deep traps, annealing was performed at temperatures between 400-800°C. It was decided that the optimum annealing temperature was 700°C, with a duration of 60 minutes. The characteristics of dose sensitivity, linearity, and reusability were analyzed to identify the effective thermoluminescence (TL) maximum on the high-temperature side of the spectrum. The whole TL glow curve was investigated through the Tm-Tstop experiment. Tm-Tstop experiment analysis determined that the luminescence curve of the natural CaCO3 mineral sample is complex.