15 November 2021 in ACS Applied Materials & Interfaces
Current infrared thermal image sensors are mainly based on planar firm substrates, but the rigid form factor appears to restrain the versatility of their applications. For wearable health monitoring and implanted biomedical sensing, transfer of active device layers onto a flexible substrate is required while controlling the high-quality crystalline interface. Here, we demonstrate high-detectivity flexible InAs thin-film mid-infrared photodetector arrays through high-yield wafer bonding and a heteroepitaxial lift-off process. An abruptly graded InxAl1–xAs (0.5 < x < 1) buffer was found to drastically improve the lift-off interface morphology and reduce the threading dislocation density twice, compared to the conventional linear grading method. Also, our flexible InAs photodetectors showed excellent optical performance with high mechanical robustness, a peak room-temperature specific detectivity of 1.21 × 109 cm-Hz1/2/W at 3.4 μm, and excellent device reliability. This flexible InAs photodetector enabled by the heteroepitaxial lift-off method shows promise for next-generation thermal image sensors.
27 October 2020 in Advanced Photonics Research
Herein, an approach to form high‐quality GaAs‐based flexible photodetectors (PDs) is first demonstrated by metal wafer bonding (MWB) and high‐throughput epitaxial lift‐off (ELO) with encapsulated thermally grown silicon dioxide (t‐SiO2) for chronic biomedical implants. The flexible GaAs PDs demonstrate responsivity over a wide range of visible and near‐infrared wavelengths. Regarding certain diagnoses, high‐performance PDs are essential for precise treatments with long‐term optoelectronic implants, and the long‐term stability and reliable encapsulation of GaAs PDs will play a major role when optoelectronics are injected into biofluids. t‐SiO2, as an encapsulation barrier, is stable without increasing the leakage current for over 120 h in phosphate‐buffered saline (PBS) at 70 °C. By Arrhenius scaling, the device shows a 700‐day lifetime with stable operation in a biofluid at 37 °C. Finally, by measuring the mass of arsenic using an inductively coupled plasma mass spectrometer (ICP/MS), the t‐SiO2 encapsulation barrier is capable of preventing toxic elements from leaching out to surrounding tissues. The technology may provide approaches based on III–V materials for expanding high‐performance optoelectronic devices to biomedical implants, namely, a broad range of high‐resolution retinal prostheses for blindness or the integration for measuring physiological parameters, such as tissue oxygenation and neural activity in the cerebral cortex.