Francesco Missiroli

Francesco Missiroli

Auto-generated profile, based on publicly available information

Francesco Missiroli

Munich Institute of Robotics and Machine Intelligence, School of Computation Information and Technology, Technical University of Munich, Garching bei Mnchen, Germany

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2022 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
MSMarek Sierotowicz
Marek Sierotowicz
NLNicola Lotti
Nicola Lotti
LNLaura Nell
Laura Nell
FMFrancesco Missiroli
Francesco Missiroli
RARyan Alicea
Ryan Alicea
Lorenzo MasiaLorenzo Masia
Lorenzo Masia
In the field of rehabilitation robotics, transparent, precise and intuitive control of hand exoskeletons still represents a substantial challenge. In particular, the use of compliant systems often leads to a trade-off between lightness and material flexibility, and control precision. In this letter, we present a compliant, actuated glove with a control scheme to detectthe user’s motion intent, which is estimated by a machine learning algorithm based on muscle activity. Six healthy study participants used the glove in three assistance conditions during a force reaching task. The results suggest that active assistance from the glove can aid the user, reducing the muscular activity needed to attain a medium-high grasp force, and that closed-loop control of a compliant assistive glove can successfully be implemented by means of a machine learning algorithm.

17 December 2021 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
ETEnrica Tricomi
Enrica Tricomi
NLNicola Lotti
Nicola Lotti
FMFrancesco Missiroli
Francesco Missiroli
XZXiaohui Zhang
Xiaohui Zhang
MXMichele Xiloyannis
Michele Xiloyannis
Lorenzo MasiaLorenzo Masia
Lorenzo Masia
Reproducing the mechanisms of human locomotion is a hard challenge. Assistive wearable devices in this context need to be lightweight, portable, and to adapt to the wearer’s walking pattern. Aiming to combine the aforementioned features, we developed a soft wearable exosuit to assist hip flexion during walking. The main feature of the device is underactuation, i.e., a single actuator is used to assist bilateral hip flexion. A control strategy based on Adaptive Oscillators and gait phase estimation is implemented to deliver flexible assistance and to adapt to changes in walking pattern. The system was tested on six healthy subjects. Preliminary results show good performance of the control algorithm to track human gait and to deliver symmetrical assistance to both legs. First kinematic and muscular assessments revealed promising results at walking speeds near to the natural human walking, where the device did not alter hip kinematics and decreased the effort required by muscles contributing to hip flexion. Once validated on a larger sample of subjects, the device can have the potentialities to be used in clinical and wellness applications.

1 October 2024 in Nature Machine Intelligence
Verified
Journal Article
Open access
PDF file
ETEnrica Tricomi
Enrica Tricomi
FMFrancesco Missiroli
Francesco Missiroli
MXMichele Xiloyannis
Michele Xiloyannis
NLNicola Lotti
Nicola Lotti
XZXiaohui Zhang
Xiaohui Zhang
Lorenzo MasiaLorenzo Masia
Lorenzo Masia
Peoples' walking efficiency declines as they grow older, posing constraints on mobility, and affecting independence and quality of life. Although wearable assistive technologies are recognized as a potential solution for age-related movement challenges, few have proven effective for older adults, predominantly within controlled laboratory experiments. Here we present WalkON, a pair of soft robotic shorts designed to enhance walking efficiency for older individuals by assisting hip flexion. The system features a compact and lightweight tendon-driven design, using a controller based on natural leg movements to autonomously assist leg propagation. To assess WalkON's impact on daily walking, we initially conducted a technology assessment with young adults on a demanding outdoor uphill 500 m hiking trail. We then validated our findings with a group of older adults walking on a flat outdoor 400 m track. WalkON considerably reduced the metabolic cost of transport by 17.79% for young adults during uphill walking. At the same time, participants reported high perceived control over their voluntary movements (a self-reported mean score of 6.20 out of 7 on a Likert scale). Similarly, older adults reduced their metabolic cost by 10.48% when using WalkON during level ground walking, while retaining a strong sense of movement control (mean score of 6.09 out of 7). These findings emphasize the potential of wearable assistive devices to improve efficiency in outdoor walking, suggesting promising implications for promoting physical well-being and advancing mobility, particularly during the later stages of life.

13 January 2022 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
FMFrancesco Missiroli
Francesco Missiroli
NLNicola Lotti
Nicola Lotti
ETEnrica Tricomi
Enrica Tricomi
CBCasimir Bokranz
Casimir Bokranz
RARyan Alicea
Ryan Alicea
Lorenzo MasiaLorenzo Masia
Lorenzo Masia
Physically demanding work is still common in western countries, with large proportions of the workforce that are exposed for more than a quarter of their working time to tiring postures or repetitive tasks: the shoulder is one of the main body areas susceptible to work-related musculo-skeletal disorders. Recent advancements in assistive technology have provided new instruments to promote safety and reduce workload. Colloquially referred to as occupational exoskeletons (OEs), these wearable devices are usually spring-loaded, and provide gravity support for overhead tasks. OEs for upper limbs are usually single-joint exoskeletons and assist shoulder flexion/extension; they do not provide support to distal joints such as the elbow. In the present work, starting from a commercially available exoskeleton, we propose an innovative concept of hybrid upper-limb OEs. We combined a spring-loaded shoulder exoskeleton with an active elbow exosuit to extend the capability of the OEs to provide gravitational support to both shoulder and elbow flexion-extension in strenuous manual tasks. The proposed device can reduce up to 32% of the biceps activity during the elbow flexion and up to 31% of the deltoids activity during the shoulder abduction. In-lab experimentation showed the potentials of such a hybrid approach in reducing the strain of the upper-limb muscles.

13 January 2022 in IEEE Transactions on Robotics
Verified
Journal Article
Closed access
NLNicola Lotti
Nicola Lotti
MXMichele Xiloyannis
Michele Xiloyannis
FMFrancesco Missiroli
Francesco Missiroli
CBCasimir Bokranz
Casimir Bokranz
DCDomenico Chiaradia
Domenico Chiaradia
Lorenzo MasiaLorenzo Masia
Lorenzo Masia
The intention-detection strategy used to drive an exosuit is fundamental to evaluate the effectiveness and acceptability of the device. Yet, current literature on wearable soft robotics lacks evidence on the comparative performance of different control approaches for online intention-detection. In the present work, we compare two different and complementary controllers on a wearable robotic suit, previously formulated and tested by our group; a model-based myoelectric control ( myoprocessor ), which estimates the joint torque from the activation of target muscles, and a force control that estimates human torques using an inverse dynamics model ( dynamic arm ). We test them on a cohort of healthy participants performing tasks replicating functional activities of daily living involving a wide range of dynamic movements. Our results suggest that both controllers are robust and effective in detecting human–motor interaction, and show comparable performance for augmenting muscular activity. In particular, the biceps brachii activity was reduced by up to 74% under the assistance of the dynamic arm and up to 47% under the myoprocessor , compared to a no-suit condition. However, the myoprocessor outperformed the dynamic arm in promptness and assistance during movements that involve high dynamics. The exosuit work normalized with respect to the overall work was $68.84 \pm 3.81\%$ when it was ran by the myoprocessor , compared to $45.29 \pm 7.71\%$ during the dynamic arm condition. The reliability and accuracy of motor intention detection strategies in wearable device is paramount for both the efficacy and acceptability of this technology. In this article, we offer a detailed analysis of the two most widely used control approaches, trying to highlight their intrinsic structural differences and to discuss their different and complementary performance.

13 March 2023 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
ETEnrica Tricomi
Enrica Tricomi
MMMirko Mossini
Mirko Mossini
FMFrancesco Missiroli
Francesco Missiroli
NLNicola Lotti
Nicola Lotti
XZXiaohui Zhang
Xiaohui Zhang
Lorenzo MasiaLorenzo Masia
Lorenzo Masia
Just like in humans vision plays a fundamental role in guiding adaptive locomotion, when designing the control strategy for a walking assistive technology, the use of computer vision may substantially improve modulation of the assistance based on the external environment. In this letter, we developed a hip exosuit controller able to distinguish among three different walking terrains through the use of an RGB camera and to adapt the assistance accordingly. The system was tested with seven healthy participants walking throughout an overground path comprising of staircases and level ground. Subjects performed the task with the exosuit disabled ( Exo Off ), constant assistance profile ( Vision Off ), and with assistance modulation ( Vision On ). Our results showed that the controller was able to classify in real-time the path in front of the user with an overall accuracy per class above the 85%, and to perform assistance modulation accordingly. Evaluation related to the effects on the user showed that Vision On was able to outperform the other two conditions: we obtained significantly higher metabolic savings than Exo Off , with a peak of $\approx$ $-20\%$ when climbing up the staircase and $\approx$ $-16\%$ in the overall path, and than Vision Off when ascending or descending stairs. Such advancements in the field may yield to a step forward for the exploitation of lightweight walking assistive technologies in real-life scenarios.