Maximilian Michael Rupp

Maximilian Michael Rupp

Auto-generated profile, based on publicly available information

Maximilian Michael Rupp

Institute for Structural Mechanics and Design, Technical University of Darmstadt, 64287 Darmstadt, Germany

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SLSteven Robert Lorenzen
Steven Robert Lorenzen
HRHenrik Riedel
Henrik Riedel
MRMaximilian Michael Rupp
Maximilian Michael Rupp
LSLeon Schmeiser
Leon Schmeiser
HBHagen Berthold
Hagen Berthold
JSJens Schneider
Jens Schneider
In the practical application of the Bridge Weigh-In-Motion (BWIM) methods, the position of the wheels or axles during the passage of a vehicle is a prerequisite in most cases. To avoid the use of conventional axle detectors and bridge type-specific methods, we propose a novel method for axle detection using accelerometers placed arbitrarily on a bridge. In order to develop a model that is as simple and comprehensible as possible, the axle detection task is implemented as a binary classification problem instead of a regression problem. The model is implemented as a Fully Convolutional Network to process signals in the form of Continuous Wavelet Transforms. This allows passages of any length to be processed in a single step with maximum efficiency while utilising multiple scales in a single evaluation. This allows our method to use acceleration signals from any location on the bridge structure and act as Virtual Axle Detectors (VADs) without being limited to specific structural types of bridges. To test the proposed method, we analysed 3787 train passages recorded on a steel trough railway bridge of a long-distance traffic line. Results of the measurement data show that our model detects 95% of the axles, which means that 128,599 out of 134,800 previously unseen axles were correctly detected. In total, 90% of the axles were detected with a maximum spatial error of 20 cm, at a maximum velocity of vmax=56.3m/s. The analysis shows that our developed model can use accelerometers as VADs even under real operating conditions.

29 June 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
MFMax Johannes Alois Fritzsche
Max Johannes Alois Fritzsche
MRMaximilian Michael Rupp
Maximilian Michael Rupp
MSMaximilian Alexander Stasica
Maximilian Alexander Stasica
ASAndré Seyfarth
André Seyfarth
JSJens Schneider
Jens Schneider
CHClemens Hübler
Clemens Hübler
Design codes for pedestrian-induced vibration on footbridges treat each pedestrian as a prescribed vertical force on the deck. This convention ignores the feedback by which deck motion modifies the gait, and at resonance overpredicts the measured field amplitudes.This paper introduces a load model for vertical human-structure interaction that closes this feedback loop. Each pedestrian is modelled as a single-degree-of-freedom oscillator whose leg stiffness varies over the gait cycle. On a vibrating deck this periodic stiffness couples the pedestrian to the deck motion. The per-step force on the bridge is then the classical rigid-ground walking force plus an interaction component proportional to the deck velocity, which acts on the deck like an amplitude-dependent damper. At resonance this damping is negative and the gait pumps energy into the deck. The response self-limits at a finite equilibrium amplitude, because the negative damping weakens as the deck amplitude rises. Away from resonance the damping stays positive.A main advantage of the proposed model is that its stability criterion and equilibrium amplitude require no prescribed driving force, unlike classical moving-force models, and that its parameters transfer to any bridge through the first-mode frequency, with the amplitude scales of the coupling tied to the comfort thresholds of design codes. A second advantage is that for groups the per-pedestrian damping contributions add linearly across the deck.Without recalibration, the model reproduces the reported field amplitudes of four independently documented footbridges within ratios 0.93 to 1.43, while classical moving-force models overestimate them by factors 3.2 to 33.The framework yields a closed-form stability criterion and a self-limiting equilibrium amplitude, both obtained without coupled crowd simulation and suited to footbridge serviceability assessment.

29 August 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
MFMax Johannes Alois Fritzsche
Max Johannes Alois Fritzsche
MRMaximilian Michael Rupp
Maximilian Michael Rupp
MSMaximilian Alexander Stasica
Maximilian Alexander Stasica
ASAndré Seyfarth
André Seyfarth
JSJens Schneider
Jens Schneider
CHClemens Hübler
Clemens Hübler
Design codes for pedestrian-induced vibration on footbridges treat each pedestrian asa prescribed vertical force on the deck. This convention ignores the feedback by which deck motion modifies the gait, and at resonance overpredicts the measured field amplitudes.This paper introduces a load model for vertical human-structure interaction that closes this feedback loop. The per-step force each pedestrian exerts on the bridge splits into two parts. The first is the classical rigid-ground walking force. The second is an interaction component proportional to the deck velocity, which acts on the deck like an amplitude-dependent damper. At resonance this damping is negative and the pedestrian injects energy into the deck. The response self-limits at a finite equilibrium amplitude, because the negative damping weakens as the deck amplitude rises. Away from resonance the coupling reduces to the positive damping the pedestrian's own body contributesA main advantage of the proposed model is that its stability criterion and equilibrium amplitude require no prescribed driving force, unlike classical moving-force models. Furthermore, its parameters transfer to any bridge through the first-mode frequency. Another advantage is that for groups the per-pedestrian damping contributions add linearly across the deck.Without recalibration, the model reproduces the reported field amplitudes of four independently documented footbridges within ratios 0.93 to 1.43, while classical moving-force models overestimate them by factors 3.3 to 33.