2 October 2024 in Russian Ophthalmological Journal
A new method of adaptive control of infusion during phacoemulsification (PE) based on the Optimed Profi (Optimedservice) surgical system was developed, allowing calculation of the predicted volume of post-occlusion surge (POS) by monitoring aspiration and infusion flow rates.Purpose. To compare POS amplitude, predicted and actual volumes of POS during experimental ex vivo PE on cadaveric porcine eyes, between Optimed Profi and Centurion Vision surgical systems.Material and methods. For two experimental PE series of 10 operations on porcine eyes, the mean POS amplitude (mm Hg) was measured using a pressure sensor in the anterior eye chamber. Predicted and actual POS volumes were assessed using a non-contact aspiration-line flowmeter sensor by varying aspiration flow rate depending on the phaco needle patency. The parameters were compared between the series using the Student t-test.Results. The mean POS amplitude during PE by Optimed Profi and Centurion Vision System was 12.10 ± 0.21 and 13.3 ± 0.3 mm Hg, respectively (p < 0.001). The mean value of the predicted POS volume during PE by Optimed Profi and Centurion Centurion Vision System was 136.80 ± 9.59 and 146.00 ± 9.46 μm, respectively (p > 0.01). The mean value of the actual POS volume during PE by Optimed Profi and Centurion Vision System was 135.30 ± 4.97 and 158.50 ± 8.63 μm, respectively (p < 0.01).Conclusion. The lower values of POS amplitude and predicted and actual volumes of POS in the series using the new method of adaptive infusion control may indicate a better hydrodynamic stability in experimental PE.
30 June 2022 in Ophthalmology in Russia
The balance between the efficiency of lens’ destruction and the safety of this process for intraocular structures is the most important aspect in the search for alternative energy approaches in cataract surgery. The article provides a literature review summarizing modern medical and technical solutions aimed at developing new and effective methods of cataract phacoemulsification. One of the main components of cataract surgery is the balance between the effectiveness of ultrasound destruction of the lens and the safety of this process for intraocular structures. Most of the available technical solutions designed to replace ultrasound do not yet allow this to be fully implemented, since they have insufficient destructive power or are technologically complex and expensive, which makes it difficult for their mass introduction into widespread practice. In this regard, it is urgent to search for alternative energy approaches aimed at increasing the efficiency of destruction without increasing the negative effects associated with an increase in ultrasound dose.
20 November 2019 in Creative surgery and oncology
Introduction. Idiopathic macular hole (IMH) is a frequent disorder of the posterior segment of the eye that impacts on visual functions leading to the reduction of visual acuity and the manifestation of metamorphopsia. In the majority of cases the basic treatment technique for IMH is a three-port transconjunctival guillotine vitrectomy. In the key of the further development of vitrectomy the latest and most interesting is the use of ultrasonic energy for vitreous fragmentation. Members of staff of the Department of Ophthalmology with the Course of Additional Professional Education of Bashkir State Medical University jointly with the Department of Microsurgical Equipment of CJSC Optimedservice have built a 25G ultrasonic vitrectomy system with the mechanism of action that turns the vitreous body into easy-to-remove emulsion with the use of ultrasound.Materials and methods. This paper presents a clinical case of idiopathic macular hole successfully treated with the method of 25G subtotal ultrasonic vitrectomy.Results and discussion. The data obtained through comprehensive ophthalmological examination and supported by fundus-camera, OCT and OCTA images made it possible to make a diagnosis of vitreomacular traction syndrome, idiopathic macular hole, J. D. Gass stage 3. 25G subtotal ultrasonic vitrectomy was performed on the universal ophthalmic surgery system Optimed Profi (Optimedservice, Russia) with intraoperative OCT-controlled internal limiting membrane staining and peeling, and apposition of the macular hole edges with gas tamponade. A good outcome, both anatomical and functional, was achieved; IMH has closed and a positive visual acuity dynamic has been recorded.Conclusion. We can thus conclude that 25G subtotal ultrasonic vitrectomy with ILM peeling and gas tamponade is an effective IMH treatment method that ensures high visual functions.
1 January 2023 in Современные проблемы науки и образования (Modern Problems of Science and Education)
28 February 2024 in Bulletin of Russian State Medical University
7 April 2024 in I.P. Pavlov Russian Medical Biological Herald
INTRODUCTION: Employees of the Department of Ophthalmology of Bashkir State Medical University, jointly with engineers of the Department of Microsurgical Equipment of Optimedservice, have developed a new method of adaptive control of infusion during phacoemulsification (PE) permitting to control the infusion flow depending on the changes in the rate of aspiration and infusion flows characteristic of a certain hydrodynamic situation, and also on the vacuum level in the aspiration line. An important aspect of safety of the new method is histological and electron microscopic examination of rabbits’ cornea in different periods after experimental PE. AIM: To evaluate histological and electron microscopic features of the rabbits’ cornea after experimental PE using a new method of adaptive control of infusion. MATERIALS AND METHODS: The experiment was conducted on 15 eyes of Chinchilla rabbits using a new method of adaptive control of infusion on the basis of Optimed Profi surgical system (Optimedservice, Russia). Histological and electron microscopic examinations of the cornea were performed on the 1st, 7th and 30th day after surgery. RESULTS: On the 1st day after surgery, according to the study data, signs of moderate edema of the corneal stroma with mild separation of collagen fiber bundles were observed. In the cell cytoplasm, signs of dystrophic processes in the epithelial cells were noticeable in the form of vacuoles of different sizes. On the 7th day after surgery, signs of alteration in the rabbits’ cornea reduced. In 30th days after surgery, based on the data of histological and electron microscopic examinations, the cornea fully corresponded to norm. CONCLUSION: The identified histological and electron microscopic alterations considerably diminish on the 7th day after surgery, and on the 30th day the ultrastructure of the cornea corresponds to the norm.