The introduction of endoscopic saphenous vein harvesting (ESVH) has been reported to decrease saphenectomy-associated wound pain and infection, compared with the traditional open conventional saphenous vein harvesting (OCSVH) technique. Despite all these benefits, the rate of adoption among surgeons has been variable. Criticism of this technique centres on the risk of injury at the time of vein harvest with its potential detrimental effect on structural viability and long-term patency. The aim of our study is to investigate the endothelial preservation of saphenous vein grafts harvested by various extraction methods. A prospective, observational study of 30 human saphenous vein grafts was performed to evaluate endothelial preservation by haematoxylin–eosin and CD 31 staining methods. The saphenous vein was harvested endoscopically either by an open tunnel (OT-ESVH), closed tunnel (CT-ESVH) or an OCSVH harvesting technique. Research samples were collected without distension to avoid intraluminal dilatation and endothelial disruption. Both haematoxylin–eosin and immunohistochemistry slides were imaged by a high-resolution slide-scanning system. Haematoxylin–eosin staining of the CT-ESVH group showed mostly preserved endothelium (P = 0.398) with some endothelial stretching (P = 1.0) and no endothelial detachment (P = 0.197). The OT-ESVH group showed marked endothelial stretching (P = 0.053). However, the OCSVH group showed significantly more endothelial detachment than the endoscopic groups (P = 0.01). The mean grading score of immunohistochemistry using the CD 31 antibody was much lower in the OT-ESVH group (1.6 ± 0.84, P = 0.009), showing more poorly preserved endothelial cells than the CT-ESVH and OCSVH groups. We observed more endothelial stretching in the OT-ESVH group, which in our opinion, was due to lack of subcutaneous tissue separation, poor visualization and traction stresses across the wall of the saphenous vein. However, the OCSVH method revealed poor endothelial protection with areas of endothelial detachment, not observed with both endoscopic techniques. Interestingly, most preserved endothelium was found in the CT-ESVH group, which was previously known to be associated with worse graft patency.
Background: Utilisation of the Endoscopic Vein Harvesting (EVH) technique has been increasing for coronary artery bypass grafting (CABG) for the last two decades. Some surgeons remain concerned about the long-term patency of the long saphenous vein harvested endoscopically compared to traditional Open Vein Harvesting (OVH). The aim of this study was to perform a retrospective analysis of the outcomes between EVH and OVH from three UK centres with 10 years follow-up. Methods: 27,024 patients underwent CABG with long saphenous vein harvested by EVH (n=13,794) or OVH (n=13,230) in three UK centres between 2007 and 2019. Propensity modelling was used to calculate the Inverse Probability of Treatment Weights (IPTW). The primary endpoint was mortality from all causes and secondary endpoints were length of hospital stay, postoperative complications, and incidence of repeat coronary re-vascularisation for symptomatic patients. IPTW was used to balance the two intervention groups for baseline and preoperative co-morbidities. Results: Median follow-up time was 4.54 years for EVH and 6.00 years for OVH. Death from any cause occurred in 13.8% of the EVH group versus 20.8% in the OVH group over the follow-up period. The hazard ratio of death (EVH to OVH) was 0.823 (95% CI: 0.767, 0.884). Length of hospital stay was similar between the groups (p=0.86). Post-operative pulmonary complications were more common in EVH vs OVH (14.7% vs. 12.8%, p<0.001), but repeat coronary re-vascularisation was similar between the groups. Conclusion: This large retrospective multicentre analysis indicates that EVH has a lower risk of mortality compared with OVH during the follow-up period of the study. The observed benefits of EVH may outweigh the risks but should be considered on a case-by-case basis. We hope this review gives confidence to other cardiac centres that offering an EVH approach to conduit harvesting does not affect long term patient outcomes.
2 September 2025 in Interdisciplinary CardioVascular and Thoracic Surgery
Objectives: Endoscopic Vessel Harvesting (EVH) devices are technically complex and the learning curve for novice practitioners can be steep, due to the need for refined hand-eye coordination and device familiarity. Training and mentoring approaches vary widely, as does the experience level of practitioners entering EVH practice. Methods: This expert review was conducted by 10 international EVH specialists from the UK, USA, and Serbia, each with 18 to 28 years of experience. Comprehensive searches of EMBASE, Cochrane, PubMed, CINAHL, and Google Scholar revealed no head-to-head comparative studies of EVH devices. As a result, the group evaluated EVH device industry specifications and white papers to analyse the evolution, component features, and limitations of current systems. Expert consensus was also sought to outline ideal device attributes and training enhancements. Results: Studies suggest the EVH learning curve ranges from 5 to 30 cases; however, studies have reported that even after 100 cases, learning may be incomplete, particularly when assessed using Optical Coherence Tomography for conduit injury. A lack of high-quality comparative studies and wide variability in device design, institutional practices, and user experience hinder conclusions about the superiority of any specific EVH system. Device choice is often based more on training background and availability than on clinical evidence. Conclusion: No existing studies link specific device-related learning curves to clinical outcomes or conduit quality. There is an apparent need for independent device evaluation, standardised training programmes and robust comparative outcome data to support evidence-based device selection that prioritises patient safety and conduit long-term patency.
Sedation during Extracorporeal Membrane Oxygenation (ECMO) is challenging due to altered pharmacokinetics. At Manchester University NHS Foundation Trust, Wythenshawe Hospital, the Richmond Agitation-Sedation Scale is the standard tool for sedation monitoring; however, it lacks precision in assessing deep sedation. Bispectral Index (BIS) monitoring offers an objective assessment but remains underused, partly because of limited nursing training. This article presents the implementation of small-group teaching sessions (SGTS) on ECMO sedation and BIS monitoring, integrated into existing ECMO refresher training. The sessions included interactive presentations, followed by anonymous feedback collection to evaluate perceptions of the clarity, relevance, appropriateness and usefulness of the SGTS. Sixty-one staff members attended, and 44 provided feedback. All respondents indicated that their learning needs were met, and 93% reported confidence in using BIS independently. The training was highly rated for clarity, relevance and practical value. Overall, our SGTS approach improved nurses’ understanding and confidence in BIS monitoring and ECMO sedation, supporting broader clinical adoption and highlighting the value of continued professional education.
Background Endoscopic Vein Harvesting (EVH) reduces wound complications compared with open vein harvesting. However, concerns remain that conduit injury may occur during the learning curve . The impact of EVH training on vein integrity and progression to independent practice remains unclear . We evaluated whether a structured EVH training programme improved vein quality, technical skill and trainee confidence. Methods This study was originally designed as a multicentre cluster-randomised trial but was prematurely halted and completed as a two-centre study with cluster allocation. Four EVH trainees were included: Two received Structured Training (ST) incorporating simulation, psychomotor reinforcement, video review and competency-based progression. Two underwent Conventional Training (CT), consisting of standard company-led training. Endothelial integrity was assessed using CD34 immunohistochemistry across proximal, random and distal sections. Endothelial stretching and muscle hypertrophy were graded. Trainee performance, anxiety and consultant-rated vein quality were recorded. Patients were followed to 12 months for Major Adverse Cardiac Events and 24 months for survival. Analyses were descriptive. Results Forty-six patients underwent EVH (ST n = 40; CT n = 6). Technical performance improved in all trainees but CT trainees discontinued independent EVH practice during the study period. ST trainees demonstrated better endothelial integrity with less stretching and muscle hypertrophy. CT vein samples showed greater endothelial variability. Clinical event rates were low. At 6–24 months, MACE was infrequent with repeat angina (4.3%), myocardial infarction (2.2%), re-intervention (6.5%) and non-cardiac death (2.2%). Among the 38 vein grafts assessed by computed tomography angiography in asymptomatic patients, 23 (60.5%) were patent, five (13.2%) demonstrated flow-limiting stenosis, and 10 (26.3%) were occluded. These findings were predominantly observed in small-calibre target vessels in patients with diabetes. Conclusion Structured EVH training was associated with better endothelial preservation during the learning curve. Given the small sample size and incomplete imaging follow-up, these findings are hypothesis-generating and require validation in larger multicentre studies. Clinical registration: ISRCTN27493194; February 2022; amended 2024. This work has been presented at International Society of Minimally Invasive Surgery (ISMICS) annual conference meeting as a e-poster online on 10-13 th June 2026. e-poster online; Available at ismics2026.109014b.NORMAL.pdf