1 July 2026 in IEEE Transactions on Industrial Electronics
23 May 2026 in International Journal of Circuit Theory and Applications
13 August 2024 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Pulse width modulators in the digital control system of the voltage source converter (VSC) are used to generate switching signals. However, their complex multi-frequency characteristics may lead to middle- and high-frequency oscillations. There are currently limited studies on the three-phase pulse width modulation (PWM) VSC considering modulator’s sideband harmonics, and the modeling methods proposed for other kinds of PWM converters are not applicable to the three-phase VSC. Therefore, to investigate the sideband harmonic stability of three-phase VSCs, the multiple Fourier series-based modeling method of the digital PWM modulator is proposed in this paper. First, the analytic expressions of switching signals when the modulator is perturbed by harmonics are derived based on the proposed method. Then, this paper summarizes the selection principles of the dominant harmonic components of the perturbed modulator. Finally, complex analytic expressions are simplified and approximated linearly to provide easy-to-use analytic results for other researchers. Then, based on the proposed modeling method, the impedance model of the VSC with a symmetric regular sampled SPWM modulator is derived. Based on the derived model, the influences of the key parameters on the system stability are investigated. Finally, the theoretical analysis results are validated through both simulations and hardware experiments.
28 April 2026 in IEEE Transactions on Power Electronics
The switching dynamics of control limiters have significantly exacerbated the transient instability risk of grid-forming (GFM) converters. However, the limiter-induced instability phenomena have not been explored extensively, and the dynamical nature has seldom been revealed due to modeling challenges and analytical method limitations. In this paper, transient instability induced by the combined effects of the current limiter and modulation limiter in the GFM converter is investigated based on the nonsmooth dynamical theory. The piecewise-smooth electromagnetic transient model of the GFM converter is first derived fully considering the switching effects of the limiters and inner loop dynamics. On this basis, the limiter-induced instability phenomena of the GFM converter under large disturbances are explored and found to be induced by hidden attractors. By bifurcation analysis, the evolution mechanism of the hidden attractors is revealed, and the parameter design guideline for the transient stability enhancement is summarized. Furthermore, the multistability phenomenon that hidden attractors coexist with a stable equilibrium is reported. Due to the fractal structure of the basins of attraction, the transient behaviors of the GFM converter are sensitive to the disturbance and lack predictability. Finally, the findings are verified by experiments.
1 May 2026 in Journal of Renewable and Sustainable Energy
To address the challenges of high-penetration renewables, hybrid systems utilizing Grid-forming voltage source converters (GFM-VSCs) and Grid-following voltage source converters (GFL-VSCs) have attracted significant attention. However, transient mode switching induced by current limiting in the GFM-VSC significantly reduces the stability margin of the hybrid systems. Addressing the challenge of accurately quantifying stability boundaries under switching-induced dynamics and coupling effects, this paper establishes the equivalent transient mathematical analysis model of the hybrid system. Subsequently, a systematic quantitative analysis method is proposed, which enables the accurate calculation of the critical clearing angle and critical clearing time by explicitly incorporating the transient mode switching of the GFM-VSC and the dynamic coupling effects. Based on the quantitative evaluation, the stability boundaries under varying control parameters and fault conditions are characterized. Furthermore, the interaction mechanism between the GFL-VSC and the GFM-VSC is unveiled, specifically how the dynamic variation of the virtual power angle difference and the current injection of the GFL-VSC impact the mode switching of the GFM-VSC. Finally, a transient synchronous stabilization enhancement strategy is proposed to facilitate the reversion of the GFM-VSC to its normal operating mode following a fault, with its effectiveness verified through simulations.