Emma Haettner

Emma Haettner

Auto-generated profile, based on publicly available information

Emma Haettner

GSI Helmholtzzentrum für Schwerionenforschung GmbH

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 March 2023 in Nature Physics
Verified
Journal Article
Closed access
PDF file
TNTakahiro Nishi
Takahiro Nishi
KIKenta Itahashi
Kenta Itahashi
DADeukSoon Ahn
DeukSoon Ahn
GBGeorg P. A. Berg
Georg P. A. Berg
MDMasanori Dozono
Masanori Dozono
PCpiAF Collaboration
piAF Collaboration

13 November 2024 in Nature
Verified
Journal Article
Open access
PDF file
GLGuy Leckenby
Guy Leckenby
RSRagandeep Singh Sidhu
Ragandeep Singh Sidhu
RCRui Jiu Chen
Rui Jiu Chen
RMRiccardo Mancino
Riccardo Mancino
BSBalázs Szányi
Balázs Szányi
JZJianwei Zhao
Jianwei Zhao
Radioactive nuclei with lifetimes on the order of millions of years can reveal the formation history of the Sun and active nucleosynthesis occurring at the time and place of its birth1,2. Among such nuclei whose decay signatures are found in the oldest meteorites, 205Pb is a powerful example, as it is produced exclusively by slow neutron captures (the s process), with most being synthesized in asymptotic giant branch (AGB) stars3–5. However, making accurate abundance predictions for 205Pb has so far been impossible because the weak decay rates of 205Pb and 205Tl are very uncertain at stellar temperatures6,7. To constrain these decay rates, we measured for the first time the bound-state β− decay of fully ionized 205Tl81+, an exotic decay mode that only occurs in highly charged ions. The measured half-life is 4.7 times longer than the previous theoretical estimate8 and our 10% experimental uncertainty has eliminated the main nuclear-physics limitation. With new, experimentally backed decay rates, we used AGB stellar models to calculate 205Pb yields. Propagating those yields with basic galactic chemical evolution (GCE) and comparing with the 205Pb/204Pb ratio from meteorites9–11, we determined the isolation time of solar material inside its parent molecular cloud. We find positive isolation times that are consistent with the other s-process short-lived radioactive nuclei found in the early Solar System. Our results reaffirm the site of the Sun’s birth as a long-lived, giant molecular cloud and support the use of the 205Pb–205Tl decay system as a chronometer in the early Solar System.

30 April 2025 in Nature
Verified
Journal Article
Open access
PDF file
PMP. Morfouace
P. Morfouace
JTJ. Taieb
J. Taieb
ACA. Chatillon
A. Chatillon
LAL. Audouin
L. Audouin
GBG. Blanchon
G. Blanchon
MZM. Zhukov
M. Zhukov
Nuclear fission leads to the splitting of a nucleus into two fragments 1,2 . Studying the distribution of the masses and charges of the fragments is essential for establishing the fission mechanisms and refining the theoretical models 3,4 . It has value for our understanding of r-process nucleosynthesis 5,6 , in which the fission of nuclei with extreme neutron-to-proton ratios is pivotal for determining astrophysical abundances and understanding the origin of the elements 7 and for energy applications 8,9 . Although the asymmetric distribution of fragments is well understood for actinides (elements in the periodic table with atomic numbers from 89 to 103) based on shell effects 10 , symmetric fission governs the scission process for lighter elements. However, unexpected asymmetric splits have been observed in neutron-deficient exotic nuclei 11 , prompting extensive further investigations. Here we present measurements of the charge distributions of fission fragments for 100 exotic fissioning systems, 75 of which have never been measured, and establish a connection between the neutron-deficient sub-lead region and the well-understood actinide region. These new data comprehensively map the asymmetric fission island and provide clear evidence for the role played by the deformed Z = 36 proton shell of the light fragment in the fission of sub-lead nuclei. Our dataset will help constrain the fission models used to estimate the fission properties of nuclei with extreme neutron-to-proton ratios for which experimental data are unavailable.

19 December 2022 in Physics in Medicine & Biology
Verified
Journal Article
Open access
DKD Kostyleva
D Kostyleva
SPS Purushothaman
S Purushothaman
PDP Dendooven
P Dendooven
EHE Haettner
E Haettner
HGH Geissel
H Geissel
CSC Scheidenberger
C Scheidenberger
Objective . Beams of stable ions have been a well-established tool for radiotherapy for many decades. In the case of ion beam therapy with stable 12 C ions, the positron emitters 10,11 C are produced via projectile and target fragmentation, and their decays enable visualization of the beam via positron emission tomography (PET). However, the PET activity peak matches the Bragg peak only roughly and PET counting statistics is low. These issues can be mitigated by using a short-lived positron emitter as a therapeutic beam. Approach. An experiment studying the precision of the measurement of ranges of positron-emitting carbon isotopes by means of PET has been performed at the FRS fragment-separator facility of GSI Helmholtzzentrum für Schwerionenforschung GmbH, Germany. The PET scanner used in the experiment is a dual-panel version of a Siemens Biograph mCT PET scanner. Main results. High-quality in-beam PET images and activity distributions have been measured from the in-flight produced positron emitting isotopes 11 C and 10 C implanted into homogeneous PMMA phantoms. Taking advantage of the high statistics obtained in this experiment, we investigated the time evolution of the uncertainty of the range determined by means of PET during the course of irradiation, and show that the uncertainty improves with the inverse square root of the number of PET counts. The uncertainty is thus fully determined by the PET counting statistics. During the delivery of 1.6 × 10 7 ions in 4 spills for a total duration of 19.2 s, the PET activity range uncertainty for 10 C, 11 C and 12 C is 0.04 mm, 0.7 mm and 1.3 mm, respectively. The gain in precision related to the PET counting statistics is thus much larger when going from 11 C to 10 C than when going from 12 C to 11 C. The much better precision for 10 C is due to its much shorter half-life, which, contrary to the case of 11 C, also enables to include the in-spill data in the image formation. Significance . Our results can be used to estimate the contribution from PET counting statistics to the precision of range determination in a particular carbon therapy situation, taking into account the irradiation scenario, the required dose and the PET scanner characteristics.

19 August 2025 in Nature Physics
Verified
Journal Article
Open access
PDF file
Daria BoscoloDaria Boscolo
Daria Boscolo
GLGiulio Lovatti
Giulio Lovatti
OSOlga Sokol
Olga Sokol
Tamara VitacchioTamara Vitacchio
Tamara Vitacchio
MMMartina Moglioni
Martina Moglioni
Marco DuranteMarco Durante
Marco Durante
Charged particle therapy with protons or heavier ions is one of the most effective radiotherapy techniques, but uncertainties in the beam range can limit its efficacy. Radioactive ion beams are ideal for image-guided particle therapy because isotopes that undergo β+ decay can be visualized with positron emission tomography. This allows spatial localization of the particle distribution in vivo, which can be correlated with the expected dose deposition for online beam range verification. Here we report the successful treatment of a mouse osteosarcoma using a radioactive 11C-ion beam. The tumour was located in the neck, close to the spinal cord, where deviations of even a few millimetres in the beam range could lead to unintended dose deposition in the spine and radiation-induced myelopathy, an injury to the spinal cord. We achieved complete tumour control with the highest dose of 20 Gy while avoiding paralysis. Low-grade neurological side effects were correlated to the activity measured by positron emission tomography in the spine. The biological washout of the activity from the tumour volume was dependent on the dose, indicating a potential component of vascular damage at high doses. This experiment marks a step towards future clinical applications of radioactive ion beams.

2 December 2024 in Physical Review Letters
Verified
Journal Article
Open access
RSRagandeep Singh Sidhu
Ragandeep Singh Sidhu
GLG. Leckenby
G. Leckenby
RCR. J. Chen
R. J. Chen
RMR. Mancino
R. Mancino
TNT. Neff
T. Neff
ECE121 Collaboration and LOREX Collaboration
E121 Collaboration and LOREX Collaboration
Stable Tl 205 ions have the lowest known energy threshold for capturing electron neutrinos ( ν e ) of E ν e ≥ 50.6 keV . The Lorandite Experiment (LOREX), proposed in the 1980s, aims at obtaining the longtime averaged solar neutrino flux by utilizing natural deposits of Tl-bearing lorandite ores. To determine the ν e capture cross section, it is required to know the strength of the weak transition connecting the ground state of Tl 205 and the 2.3 keV first excited state in Pb 205 . The only way to experimentally address this transition is to measure the bound-state beta decay ( β b ) of fully ionized Tl 81 + 205 ions. After three decades of meticulous preparation, the half-life of the β b decay of Tl 81 + 205 has been measured to be 291 − 27 + 33 days using the Experimental Storage Ring (ESR) at GSI, Darmstadt. The longer measured half-life compared to theoretical estimates reduces the expected signal-to-noise ratio in the LOREX, thus challenging its feasibility. Published by the American Physical Society 2024