Zhuangzhuang Li

Zhuangzhuang Li

Auto-generated profile, based on publicly available information

Zhuangzhuang Li

Department of Orthopedics Orthopedic Research Institute, West China Hospital, Sichuan University Chengdu China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2024 in Orthopaedic Surgery
Verified
Journal Article
Open access
ZLZhuangzhuang Li
Zhuangzhuang Li
MLMinxun Lu
Minxun Lu
YZYuqi Zhang
Yuqi Zhang
JWJie Wang
Jie Wang
YWYitian Wang
Yitian Wang
CTchongqi tu
chongqi tu
Objective: Geographic defect reconstruction in load‐bearing bones presents formidable challenges for orthopaedic surgeon. The use of 3D‐printed personalized implants presents a compelling opportunity to address this issue. This study aims to design, manufacture, and evaluate 3D‐printed personalized implants with irregular lattice porous structures for geographic defect reconstruction in load‐bearing bones, focusing on feasibility, osseointegration, and patient outcomes.Methods: This retrospective study involved seven patients who received 3D‐printed personalized lattice implants for the reconstruction of geographic defects in load‐bearing bones. Personalized implants were customized for each patient. Randomized dodecahedron unit cells were incorporated within the implants to create the porous structure. The pore size and porosity were analyzed. Patient outcomes were assessed through a combination of clinical and radiological evaluations. Tomosynthesis‐Shimadzu metal artifact reduction technology (T‐SMART) was utilized to evaluate osseointegration. Functional outcomes were assessed according to the Musculoskeletal Tumor Society (MSTS) 93 score.Results: Multiple pore sizes were observed in porous structures of the implant, with a wide distribution range (approximately 300–900 um). The porosity analysis results showed that the average porosity of irregular porous structures was around 75.03%. The average follow‐up time was 38.4 months, ranging from 25 to 50 months. Postoperative X‐rays showed that the implants matched the geographic bone defect well. Osseointegration assessments according to T‐SMART images indicated a high degree of bone‐to‐implant contact, along with favorable bone density around the implants. Patient outcomes assessments revealed significant improvements in functional outcomes, with the average MSTS score of 27.3 (range, 26–29). There was no implant‐related complication, such as aseptic loosening or structure failure.Conclusion: 3D‐printed personalized lattice implants offer an innovative and promising strategy for geographic defect reconstruction in load‐bearing bones. This approach has the potential to match the unique contours and geometry of the geographic bone defect and facilitate osteointegration.

10 October 2024 in Virtual and Physical Prototyping
Verified
Journal Article
Open access
ZLZhuangzhuang Li
Zhuangzhuang Li
MLMinxun Lu
Minxun Lu
HLHaoyuan Lei
Haoyuan Lei
SZShanfang Zou
Shanfang Zou
RLRuicheng Liu
Ruicheng Liu
CTChongqi Tu
Chongqi Tu

18 December 2023 in Orthopaedic Surgery
Verified
Journal Article
Open access
ZLZhuangzhuang Li
Zhuangzhuang Li
MLMinxun Lu
Minxun Lu
YZYuqi Zhang
Yuqi Zhang
JWJie Wang
Jie Wang
YWYitian Wang
Yitian Wang
CTchongqi tu
chongqi tu
Background: Intercalary reconstruction for patients with short residual bone segments remains challenging. Three‐dimensional (3D)‐printed custom‐made porous implants are a promising technique for short‐segment fixation in these patients. This study aims to evaluate the efficiency of 3D‐printed custom‐made porous components (3DCPCs) for short‐segment fixation, focusing on prosthesis survivorship, radiographic results, and potential complications.Methods: This retrospective study involved 39 patients who underwent intercalary prosthetic reconstruction with 3DCPCs after tumor resection of the femur, tibia, or humerus from June 2015 to October 2020. Segment bone loss involved the femur (n = 15), tibia (n = 16), and humerus (n = 8), leaving 78 residual bone segments. There were 46 short segments requiring 46 3DCPCs and 32 segments with the ability to accommodate 32 off‐the‐shelf standard uncemented stems for prosthesis fixation. Clinical and functional outcomes were evaluated. Prosthesis‐overall survivorship and prosthesis‐specific survivorship were analyzed using Kaplan–Meier survival analysis. Radiographic results and modes of failure of using this technique were also examined.Results: The mean follow‐up was 41 months. The prosthesis‐overall survivorship was 87.2% and 84.6% at 2 and 5 years, respectively. The prosthesis‐specific survivorship was 92.1% and 89.5% at 2 and 5 years, respectively. There was not a substantial difference in prosthesis survivorship among the femur, tibia, and humerus. The average MSTS score was 26.2, ranging from 22 to 28. The radiographic evaluation results revealed excellent or good interface (38/46) in most of the 46 porous components. A total of 38 of 46 bone segments’ remolding demonstrated no change. In total, seven patients (16.3%) had complications requiring further surgery.Conclusion: The prosthesis survivorship of using 3DCPCs for short‐segment fixation is similar or better compared to other studies involving intercalary prosthetic reconstruction with short‐segment fixation. Radiographic evaluation revealed good osteointegration and avoidance of stress shielding. Overall, intercalary prosthetic reconstruction with 3DCPC is a feasible modality for patients with short residual bone segments after tumor resection.

24 November 2024 in Orthopaedic Surgery
Verified
Journal Article
Open access
XHXuanhong He
Xuanhong He
YLYi Luo
Yi Luo
CZChang Zou
Chang Zou
MLMinxun Lu
Minxun Lu
YZYuqi Zhang
Yuqi Zhang
CTchongqi tu
chongqi tu
Objective: Type III hemipelvectomy and reconstruction are challenging. Several reconstruction options, including autologous soft tissue, prosthesis patch, autologous, or allograft, were reported, but a variety of shortcomings limited their application. Three‐dimensional (3D)‐printed prosthesis was designed to reconstruct the unilateral Type III pelvic defect and had favorable clinical outcomes. However, the reconstruction method for bilateral Type III pelvic defect was few reported. This study aims to design a bilateral pubis prosthesis and evaluate the early clinical outcomes and complications.Methods: We retrospectively collected patients receiving 3D‐printed bilateral pubis prosthesis reconstruction after malignant tumor resection between 2017 and 2021. Demographics, anatomic data, operation time, blood loss, and clinical outcomes of patients were analyzed. The Musculoskeletal Tumor Society‐93 (MSTS‐93) score was performed to evaluate the function and complications were recorded.Results: Four patients, including three for females and one for males, were enrolled in this study. Prosthesis was designed according to the pelvic anatomical data. The mean operation time and blood loss were 308.8 min (range, 240–400 min) and 655 mL (range, 400–1100 mL), respectively. The average follow‐up was 15.5 months (range, 12–16 months). The mean MSTS was 28.5 (28–29). One patient had incision necrosis postoperatively. No hernia, prosthesis displacement, or implant failure occurred during follow‐up. Four patients with 15 interfaces showed good osteointegration.Conclusions: 3D‐printed bilateral pubis prosthesis could restore the integrity and stability of pelvic ring and improve limb function. Meanwhile, this reconstruction option provided a rigid bony‐soft support to prevent the development of hernia. In all, 3D‐printed bilateral pubis prosthesis is recommended to be a favorable selection for Type III pelvic defect reconstruction.

11 November 2024 in Orthopaedic Surgery
Verified
Journal Article
Open access
WWWeiyi Wang
Weiyi Wang
JAJingjing An
Jingjing An
MLMinxun Lu
Minxun Lu
XHXuanhong He
Xuanhong He
ZLZhuangzhuang Li
Zhuangzhuang Li
CTchongqi tu
chongqi tu
Background: Malignant tumors originating in the talus are rare and present significant challenges in reconstruction. Traditional treatments, such as below‐knee amputation or tbiocalcaneal fusion, often result in significant loss of ankle function. After tumor resection, reconstruction of the talus and calcaneus is necessary to preserve ankle function. However, the intricate anatomical structure and unique location of the talus and calcaneus present significant challenges for prosthetic reconstruction.Case Presentation: Here, we present the case of an 11‐year‐old adolescent patient diagnosed with Ewing's sarcoma of the talus, accompanied by suspected involvement of the calcaneus. Following a comprehensive evaluation, a 3D‐printed talus‐calcaneus prosthesis, which is composed of a ultrahigh‐molecular weight polyethylene (UHMWPE) part and a titanium alloy part, was designed for talus and calcaneus reconstruction. In addition, a porous structure was designed to promote the integration of bone–prosthesis interface. The lesion was completely resected and the prosthesis was precisely installed. After 12 months follow‐up, patients demonstrated favorable function results with the Musculoskeletal Tumor Society (MSTS) score was 27/30, and the American Orthopedic Foot and Ankle Society (AOFAS) score was 92/100. The range of motion for dorsiflexion, plantarflexion, inversion, and eversion of the right ankle joint was measured as 10° and 35°, 15°, and 10°, respectively. The postoperative radiograph showed a good position of the prosthesis. No narrowed joint space was observed. Tomosynthesis shimadzu metal artifact reduction technology (T‐SMART) revealed that integration between bone and prosthesis was good.Conclusion: In this case, we present a case of 3D‐printed talus‐calcaneal prosthesis reconstructing talus and calcaneus. Favorable postoperative function outcome and good integration of the interface were observed. Therefore, this case provides an alternative therapeutic option for the treatment invasive talus tumor accompanied by suspicious contamination of the calcaneus. Nevertheless, a larger cohort study and with longer follow‐up is needed to evaluate the effectiveness and potential complications of this novel prosthesis.

4 June 2024 in Orthopaedic Surgery
Verified
Journal Article
Open access
ZLZhuangzhuang Li
Zhuangzhuang Li
YLYi Luo
Yi Luo
MLMinxun Lu
Minxun Lu
YWYitian Wang
Yitian Wang
TGTaojun Gong
Taojun Gong
CTchongqi tu
chongqi tu
Objective: Management of extensive acetabular bone defects in total hip arthroplasty (THA) remains challenging. This study aims to investigate the feasibility and preliminary outcomes of 3D‐printed personalized porous acetabular components for the reconstruction of acetabular defects in primary THA.Methods: This retrospective study involved seven patients who received 3D‐printed acetabular components in primary THA between July 2018 and March 2021. Preoperatively, acetabular bone defects were evaluated by referencing the Paprosky classification. There were two "Paprosky type IIIA" defects and five "Paprosky type IIIB" defects. The acetabular components were custom‐made for each patient to reconstruct the extensive acetabular defects. The hip function was assessed according to the Harris hip score (HHS). Clinical and radiographic outcomes were assessed.Results: The average follow‐up period was 40 months, ranging from 26 to 57 months. There were no patients lost to follow‐up. The HHS improved from 44 (range: 33–53) before the operation to 88 (range: 79–93) at the final follow‐up. Postoperative X‐rays showed that the 3D‐printed personalized components were properly fitted with the acetabulum. The average center of rotation (COR) discrepancy was 2.3 mm horizontally and 2.1 mm vertically, respectively. Tomosynthesis‐Shimadzu metal artifact reduction technology images showed that the implant was in close contact with the host bone. Moreover, no complications were observed during the follow‐up period, including loosening, dislocation, or component protrusion.Conclusion: The implantation of 3D‐printed personalized acetabular components showed accurate reconstruction, stable mechanical support, and favorable function at short‐term follow‐up. This may be a viable alternative method for reconstructing extensive acetabular defects in THA.