7 June 2021 in Rheumatology International
1 January 2008 in Blood Pressure
Self‐measurement of blood pressure (BP) at home is more common than 10 years ago and encouraged by current guidelines to increase patient adherence to treatment and reach the goal of target BP. The aims of this study are to evaluate the accuracy of home sphygmomanometers and to investigate behavior/knowledge of the sphygmomanometer owners. A campaign was planned to determine the accuracy of home sphygmomanometers in 2006. Seven hundred and twenty‐three home sphygmomanometers were brought by individuals to the University Hospital Hypertension Clinic within 1 year and 693 (96%) of the devices were in adequate working condition and suitable for analysis. Four hundred and thirty‐nine (63%) of the sphygmomanometers were automatic. Four hundred and eleven (59.3%) of the 693 sphygmomanometer were inaccurate. About 80% (256/320) of the wrist devices were inaccurate. Most studies evaluating the accuracy of sphygmomanometers are conducted in hospital or primary care settings; studies investigating home sphygmomanometers are rare. High frequency of inaccurate home devices is a major public health problem. In conclusion, inaccurate devices have been used in home BP measurements frequently and frequency of device‐related errors can be decreased by awareness and training of the patients. Physicians and healthcare providers should advise the patients to check the accuracy of their home sphygmomanometers regularly.
16 August 2022 in Irish Journal of Medical Science (1971 -)
29 July 2013 in Journal of Experimental and Clinical Medicine
20 July 2009 in Kidney and Blood Pressure Research
DEDilek Gurgenyatagi Erdem
+2
Background/Aims: The aims of this study are to assess the reasons of using sphygmomanometers at pharmacies and to evaluate their accuracy. Methods: 135 devices (118 aneroid, 1 mercury, and 16 automated) from 125 pharmacies (located in Samsun city center) were included in the study. A non-randomized, cross-sectional design was used for the study protocol which had two parts: assessment of devices and a questionnaire about the pharmacy and present sphygmomanometer(s). Results: 40 (30%) of the 135 sphygmomanometers were inaccurate. 65 (48%) of the devices were older than 1 year and there was no correlation between the duration of the ownership of the sphygmomanometers and their inaccuracy (p > 0.05). Blood pressure measurement is a frequent practice at pharmacies. The aneroid type of sphygmomanometers was common. A limited number of devices were checked for accuracy before. The number of validated devices was low. Conclusion: Training programs for pharmacists including the accuracy of sphygmomanometers and regular checks of sphygmomanometers for accuracy will be beneficial to the community and to the subjects requesting measurement of blood pressure at the pharmacies.
1 May 2002 in Rheumatology