Carl Oskar Paulrud

Carl Oskar Paulrud

Auto-generated profile, based on publicly available information

Carl Oskar Paulrud

DeLaval International, Tumba 14741, Sweden

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Journal of Dairy Science
Verified
Journal Article
Open access
DRD.J. Reinemann
D.J. Reinemann
BBB.H.P. van Den Borne
B.H.P. van Den Borne
HHH. Hogeveen
H. Hogeveen
MWM. Wiedemann
M. Wiedemann
CPC.O. Paulrud
C.O. Paulrud
The objective of this study was to compare a vacuum control system that increases milking system vacuum during the peak flow period of milking to conventional constant vacuum control technology regarding its effect on milk flowrate and milking duration. Further objectives were to study the effects of flow-controlled vacuum on milking parlor performance. An observational study was conducted on a commercial dairy farm milking from 848 to 896 cows per day over the study period using a 60-stall rotary milking parlor. The flow-controlled vacuum control system was applied for 3 wk. Milking performance and teat condition were compared with 3-wk periods prior and subsequent to the test period using conventional vacuum control. Statistical analysis was performed assuming a cross-sectional study design during each period. Flow-controlled vacuum increased peak milk flowrate by 12% and increased average milk flowrate by 4%. The decrease in individual cow milking duration was proportional to milk yield per milking. Postmilking teat condition was good during the entire study period. The occurrence of rough teat ends was slightly reduced during the flow-controlled vacuum period with no meaningful difference in the occurrence of teats with blue color, palpable rings, or petechia. The combination of reduced vacuum during the low flow period of milking and the decrease in milking duration are likely factors that are protective of teat tissues. Bioeconomic modeling of the use of flow-controlled vacuum on the performance of rotary milking parlors, using the data that were collected during the study, showed that the reduction in milking duration of individual cows allows a higher rotary parlor speed. Modeled parlor throughput increased by 5.0% to 419 cows/h, 6.8% to 407 cows/h, and 4.2% to 326 cows/h when 80%, 95%, and 99% of the cows were finished milking at the end of the rotation for a 60-stall parlor. Model results showed that increased parlor throughput resulted in increased labor efficiency, reduced labor costs for milking, and a positive benefit-cost ratio on the investment for all but the smallest herd and parlor sizes considered.

1 November 2025 in Journal of Dairy Science
Verified
Journal Article
Open access
JUJohn Upton
John Upton
RBR.M. Bruckmaier
R.M. Bruckmaier
GMG.A. Mein
G.A. Mein
DRD.J. Reinemann
D.J. Reinemann
MWMatthias Josef Wieland
Matthias Josef Wieland
MRM D Rasmussen
M D Rasmussen
The broad focus of this review is on milk harvesting in machine-milked herds. With particular emphasis on: (1) milk secretion and storage dynamics in the udder, (2) milk ejection, (3) milk flow profiles and their effect on milking efficiency, (5) immunological activity and milking efficiency, (5) milking machine aspects of milk removal, and (6) the future potential of milking technology. Machine milking has evolved from its early mechanical beginnings into a technologically advanced, data-driven process that must balance speed, chosen completeness, and gentleness on teat tissue to support efficient milk removal and optimal udder health. This review summarizes the current understanding of milk harvesting from a physiological, mechanical, and managerial perspective and outlines the key factors shaping its future development. Fundamentally, milk harvesting is built upon a biological sequence involving milk synthesis, ejection, and removal. Milk synthesis occurs at the alveolar level and is influenced by local quarter-specific physiology. Milk ejection is driven by the oxytocin-mediated contraction of myoepithelial cells, a process sensitive to the degree of udder filling, familiarity with the milking environment, and cow-operator interactions. Milk flow profiles, shaped by these biological processes, provide crucial insights into milking efficiency and udder health outcomes. At the machine level, key variables include milking vacuum, pulsation characteristics, liner properties, and teatcup removal strategies. Optimal settings for each of these parameters depend on dynamic interactions with cow physiology and milking stage. Recent research highlights the need to consider these factors not in isolation but as part of an integrated milking system, where vacuum, pulsation, liner design, and timing of teatcup removal interact to affect milking speed, teat condition, and udder health. Automation of milking systems and indeed automated milking systems have driven a shift toward individualized milking at the quarter level, enabling more precise control of extraction timing and flow rate. The integration of real-time sensor data, machine learning, and adaptive milking parameters represents a major step forward in the optimization of milking systems. In the near future, distinctions between automated milking systems and conventional systems will become increasingly blurred, as both adopt automation and intelligent controls tailored to individual cows and quarters. This review also explores the role of immunological activity in shaping milking efficiency. Elevated SCC has been associated with altered milk flow curves and decreased productivity. There is emerging evidence suggesting that modern selection and management strategies may reduce the historical link between fast milking and mastitis risk. This relationship remains complex and context dependent. The detection and management of abnormal milk (supported by more advanced inline sensor systems) is expected to become a cornerstone of future milking technology. Looking forward, the drivers of change in milk harvesting will include labor availability, economic pressures, environmental concerns, animal health, and consumer expectations. A new era of biologically aware, data-informed, and precision-engineered milking systems is emerging. These systems will support the gentle, efficient removal of milk to a user-defined end point, tailored to each animal and each milking event.

1 December 2024 in Journal of Dairy Science
Verified
Journal Article
Open access
ASAjay Singh
Ajay Singh
MSMadeleine Spellman
Madeleine Spellman
HSH. Somula
H. Somula
KKK. Kakoulis
K. Kakoulis
CPC.O. Paulrud
C.O. Paulrud
MWMatthias Josef Wieland
Matthias Josef Wieland
The objectives of this study were to assess the effect of flow-responsive vacuum and pulsation, in conjunction with the early attachment of the milking unit (TRT), on teat tissue conditions and milking characteristics in dairy cows. In a switch-back trial, 5,235 Holstein cows milked 3 times daily in a rotary parlor were assigned to the TRT or control (CON) group. The trial lasted 84 d and was comprised of 4 alternating 3-week periods of TRT and CON. For both groups, premilking udder preparation consisted of teat brushing, forestripping and predipping, and wiping of teats, resulting in a stimulation time of 4 s. In the TRT group, the preparation lag time was 58 s, and in the CON group, it was 91 s for early- and mid-lactation cows and 105 s for late-lactation animals. Upon milking unit attachment, the TRT cows were milked at a lower vacuum (37.6 kPa) and pulsation (50 cycles/min, pulsation ratio of 30:70). The vacuum and pulsation settings were changed to milking mode when the milk flow reached 0.5 kg/min (pulsation switch-point) and 1.6 kg/min (vacuum switch-point). For milking mode, the vacuum setting was 47.7 kPa, and the pulsation rate was 60 cycles/min at a ratio of 65:35. The CON cows were milked with a flow-responsive vacuum, using the same vacuum settings as the TRT group. We assessed machine milking-induced short-term teat tissue changes and teat-end hyperkeratosis by palpation and visual inspection postmilking. Electronic on-farm milk meters were used to assess milking characteristics. Generalized linear mixed models were used to analyze the effect of treatment on the outcome variables. Compared with cows in group CON, the odds ratios (95% confidence interval; 95% CI) of short-term teat-tissue changes in early-, mid-, and late lactation cows in group TRT were 0.62 (0.52-0.76), 0.61 (0.48-0.77), and 0.93 (0.76-1.14), respectively. The least squares means [LSM, (95% CI)] for milking unit-on time in early-, mid-, and late lactation animals, respectively, were 251 (248-253), 236 (234-238), and 220 (218-222) s for group TRT and 247 (245-249), 232 (230-234), and 214 (213-216) s for the CON group. The LSM (95% CI) of peak milk flow rate in early-, mid-, and late lactation animals, respectively, were 5.75 (5.68-5.82), 5.77 (5.70-5.84), and 5.54 (5.48-5.59) kg/min for the TRT cows and 5.65 (5.58-5.72), 5.74 (5.68-5.81), and 5.45 (5.40-5.51) kg/min for the CON cows. The odds ratios (95% CI) of forced take-off in group TRT for early-, mid-, and late lactation cows, respectively, were 0.39 (0.37-0.41), 0.32 (0.30-0.34), and 0.47 (0.44-0.52) compared with their respective CON groups. In this study, cows that were milked using flow-responsive vacuum and pulsation with early attachment of the milking unit had lower odds of short-term teat tissue changes and forced take-off, as well as a higher peak milk flow rate. Our data suggest that the application of flow-responsive vacuum and pulsation facilitates early attachment of the milking unit, improves teat tissue condition, and has the potential to improve parlor efficiency.

1 November 2025 in JDS Communications
Verified
Journal Article
Open access
DRD.J. Reinemann
D.J. Reinemann
CPC.O. Paulrud
C.O. Paulrud
JWJohan ter Weele
Johan ter Weele
Summary: This paper presents the results of a field test of a vacuum-control system, flow-responsive milking (FRM), applied to the DeLaval VMS automatic milking system that maintains teat-end vacuum during the milking process with the aim of reducing milking duration. This FRM system was implemented on an automatic milking installation and resulted in increased milk flow rates at the udder and quarter level, with indications of more complete milking, and demonstrated the potential to improve the capacity of automatic milking installations.

1 December 2025 in Journal of Dairy Science
Verified
Journal Article
Open access
MWMatthias Josef Wieland
Matthias Josef Wieland
CPC.O. Paulrud
C.O. Paulrud
KKK. Kakoulis
K. Kakoulis
MSMadeleine Spellman
Madeleine Spellman
HSH. Somula
H. Somula
ASAjay Singh
Ajay Singh
The objectives were to investigate the association between machine milking-induced teat tissue changes and the occurrence of clinical mastitis in Holstein dairy cows. We conducted 2 separate prospective cohort studies at 1 commercial dairy farm in New York State to study the association of machine milking-induced short-term changes (STC, trial 1) and machine milking-induced long-term changes (LTC, trial 2) with clinical mastitis occurrence. Each trial consisted of four 3-wk periods. On d 1 of each period, STC and LTC were assessed through visual inspection and manual palpation. Short-term teat tissue changes were assessed based on teat discoloration, the condition of the teat base, and the consistency of the teat end and categorized into a binary variable (STC present or absent). Long-term teat tissue changes were categorized into 4 groups as follows: no callosity present (score 1), callosity ring present with no or only mild roughness (score 2); callosity ring and roughness present with keratin fronds extending 1 to 3 mm from the teat orifice (score 3); and callosity ring present with excessive keratin fronds extending ≥4 mm from the teat orifice (score 4). Data on clinical mastitis occurrence was extracted from the herd management software. We used the first clinical mastitis event of a quarter for each 3-wk trial period and applied a 14-d gap to define a new mastitis case within a quarter between 2 trial periods. In trial 1, STC was documented in 6,110 of 66,702 cases (9.2%) over the four 3-wk periods, The frequency distribution of LTC in trial 2 was as follows: score 1 in 7,348 of 61,624 cases (11.9%), score 2 in 48,553 cases (78.8%), score 3 in 5,514 cases (8.9%), and score 4 in 209 cases (0.3%). We documented 944/66,702 (1.4%) clinical mastitis cases at the quarter level during trial 1 and 866/61,624 (1.4%) cases during trial 2. Generalized linear mixed models with a logit link and a binomial distribution were used to test if machine milking-induced teat tissue changes were associated with clinical mastitis occurrence. In trial 1, we analyzed 66,702 quarter-level observations from 5,094 cows. We found no significant association between STC and clinical mastitis occurrence. Compared with a quarter with a teat without STC, the odds (95% CI) of clinical mastitis were 1.22 (0.95-1.59). In trial 2, we used 61,624 quarter-level observations from 4,998 cows. We found no significant association between LTC and clinical mastitis occurrence. Compared with a quarter with a teat with a smooth end (score 1), the odds of a clinical mastitis case were 1.02 (0.77-1.36) for score 2, 1.19 (0.84-1.69) for score 3, and 2.14 (0.80-5.71) for score 4. We concluded that in the study cohort presented here, machine milking-induced teat tissue changes were not associated with the occurrence of clinical mastitis.

1 December 2024 in Journal of Dairy Science
Verified
Journal Article
Open access
PFPatricia Fürst
Patricia Fürst
MAMoritz Affentranger
Moritz Affentranger
CPCarl Oskar Paulrud
Carl Oskar Paulrud
RBRupert M. Bruckmaier
Rupert M. Bruckmaier
Dairy cows usually store more milk in rear than in front quarters. At conventional machine milking this leads to an earlier cessation of milk flow in front than in rear quarters and hence unavoidable milking on empty front teats. We tested the hypothesis that an increased pulsation ratio in rear quarters reduces both milking on empty front teats and machine-on time. We have also tested if the different amplitude of cyclic vacuum fluctuations during milking with simultaneous vs. alternate pulsation within front and rear quarters, respectively, impacts milking characteristics. Ten Holstein dairy cows were milked twice daily at 14-h and 10-h milking intervals. Pulsation ratio in front quarters was 65:35, but was either set at 65:35, 70:30, 75:25 or 80:20 in rear quarters. Whole udder milk flow, claw vacuum, and mouthpiece chamber vacuum of all 4 quarters were recorded during milking. Teat tissue thickness of all 4 teats was measured with a cutimeter at 5 and 30 min after cluster detachment. Total milk yield did not differ among treatments, indicating complete udder emptying. The time of quarter milk flow (tQMF) of front quarters did not differ among treatments but decreased with increasing pulsation ratio in rear quarters. In addition, the faster milking of rear quarters at higher pulsation ratio caused higher peak and average milk flow rates, a shorter duration of milk flow decline, and a reduced machine-on time. The increased milk flow at a higher pulsation ratio did not cause a significant reduction of the claw vacuum at the used sample size. Teat tissue thickness did not significantly differ among treatments, likely because milking on empty teats did almost not occur in the rear quarters, and treatment settings did not differ in front quarters. Simultaneous pulsation caused higher amplitudes of cyclic vacuum fluctuation than alternate pulsation. However, milking characteristics did not differ between simultaneous and alternate pulsation. In conclusion, an increased pulsation ratio in rear quarters reduces machine-on time, increases milking performance, and reduces the time of milking on empty teats in front quarters, without an increased impact on teat tissue thickness.