13 January 2023 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
23 June 2022 in Journal of Synchrotron Radiation
Undulators are important devices for accelerator-based light sources whose magnetic field quality determines the photon beam performance. Superconducting-type undulators have been developing rapidly in recent years around the world. The insertion device group at the Institute of High Energy Physics (IHEP) in China started an R&D project to develop prototypes of superconducting undulators (SCUs). A half-meter-long planar SCU has been produced recently. The SCU was designed based on the simulation program OPERA-3D giving a period length of 15 mm and a gap of 7 mm. This prototype was manufactured and fabricated precisely, and was then tested by vertically submerging in liquid helium in a Dewar. After quench training several times, the maximum current in the main coils reached 480 A. The magnetic field was measured by Hall probes mounted on a sledge in the middle of the undulator gap. The peak magnetic field reached 1 T. The measurement results indicate that correction coils with suitable current can not only optimize the magnetic first and second integrals but also reduce the phase error, which is expected by design.
21 November 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
21 February 2024 in Physical Review Accelerators and Beams
Taking advantage of a higher field than a conventional permanent magnet undulator, superconducting undulators (SCUs) have been rapidly developed in recent years for applications at synchrotron radiation sources and free-electron lasers. The Institute of High Energy Physics, Chinese Academy of Sciences, has developed a 1.5-m long planar SCU with a short period of 15 mm. This SCU has been commissioned and optimized in the horizontal position. In contrast to the vertical position, where the undulator coils are immersed in liquid helium for superconductivity, the horizontal test requires the assembly of the complete device, including the cryostat, current conductor, cryocooler, vacuum chamber, and undulator coils. This test reflects the operation status and measures the SCU’s characteristics under working conditions. Although experiences from the vertical test provided good guidance for horizontal optimization, special care needs to be taken for effects such as gravity. After improving field uniformity through iterative measurements, the rms phase error of the SCU is reduced to 7.3° at a current of 400 A. Additionally, the functions of the end correction coils to mitigate field integral errors have been verified. This paper also demonstrates and analyzes other phenomena and interesting observations during the commissioning process. It discusses important issues that impact field quality and measurement accuracy and suggests further improvement measures for an even better field. Published by the American Physical Society 2024