Cyndia Yu

Cyndia Yu

Auto-generated profile, based on publicly available information

Cyndia Yu

University of Chicago

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2019 in Journal of Cosmology and Astroparticle Physics
Verified
Journal Article
Closed access
PDF file
PAPeter Ade
Peter Ade
JAJames Aguirre
James Aguirre
ZAZeeshan Ahmed
Zeeshan Ahmed
SASimone Aiola
Simone Aiola
AAAamir Ali
Aamir Ali
TCThe Simons Observatory collaboration
The Simons Observatory collaboration
The Simons Observatory (SO) is a new cosmic microwave background experiment being built on Cerro Toco in Chile, due to begin observations in the early 2020s. We describe the scientific goals of the experiment, motivate the design, and forecast its performance. SO will measure the temperature and polarization anisotropy of the cosmic microwave background in six frequency bands centered at: 27, 39, 93, 145, 225 and 280 GHz. The initial configuration of SO will have three small-aperture 0.5-m telescopes and one large-aperture 6-m telescope, with a total of 60,000 cryogenic bolometers. Our key science goals are to characterize the primordial perturbations, measure the number of relativistic species and the mass of neutrinos, test for deviations from a cosmological constant, improve our understanding of galaxy evolution, and constrain the duration of reionization. The small aperture telescopes will target the largest angular scales observable from Chile, mapping ≈ 10% of the sky to a white noise level of 2 μK-arcmin in combined 93 and 145 GHz bands, to measure the primordial tensor-to-scalar ratio,r, at a target level of σ(r)=0.003. The large aperture telescope will map ≈ 40% of the sky at arcminute angular resolution to an expected white noise level of 6 μK-arcmin in combined 93 and 145 GHz bands, overlapping with the majority of the Large Synoptic Survey Telescope sky region and partially with the Dark Energy Spectroscopic Instrument. With up to an order of magnitude lower polarization noise than maps from thePlancksatellite, the high-resolution sky maps will constrain cosmological parameters derived from the damping tail, gravitational lensing of the microwave background, the primordial bispectrum, and the thermal and kinematic Sunyaev-Zel'dovich effects, and will aid in delensing the large-angle polarization signal to measure the tensor-to-scalar ratio. The survey will also provide a legacy catalog of 16,000 galaxy clusters and more than 20,000 extragalactic sources.

20 June 2019 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
SZS. Y. Frank Zhao
S. Y. Frank Zhao
NPNicola Poccia
Nicola Poccia
MPMargaret G. Panetta
Margaret G. Panetta
CYCyndia Yu
Cyndia Yu
JJJedediah W. Johnson
Jedediah W. Johnson
PKPhilip Kim
Philip Kim
We developed novel techniques to fabricate atomically thin Bi2.1Sr1.9CaCu2.0O8+δ van der Waals heterostructures down to two unit cells while maintaining a transition temperature Tc close to the bulk, and carry out magnetotransport measurements on these van der Waals devices. We find a double sign change of the Hall resistance Rxy as in the bulk system, spanning both below and above Tc. Further, we observe a drastic enlargement of the region of sign reversal in the temperature-magnetic field phase diagram with decreasing thickness of the device. We obtain quantitative agreement between experimental Rxy(T,B) and the predictions of the vortex dynamics-based description of Hall effect in high-temperature superconductors both above and below Tc.

21 December 2017 in Nano Letters
Verified
Journal Article
Closed access
SZS. Y. Frank Zhao
S. Y. Frank Zhao
GEGiselle A. Elbaz
Giselle A. Elbaz
DBD. Kwabena Bediako
D. Kwabena Bediako
CYCyndia Yu
Cyndia Yu
DEDmitri K. Efetov
Dmitri K. Efetov
PKPhilip Kim
Philip Kim

18 July 2018
Verified
Conference Paper
Closed access
PDF file
SHShawn W. Henderson
Shawn W. Henderson
ZAZeeshan Ahmed
Zeeshan Ahmed
DBDavid Brown
David Brown
SCSaptarshi Chaudhuri
Saptarshi Chaudhuri
HCHsiao-Mei Sherry Cho
Hsiao-Mei Sherry Cho
MVMichael Vissers
Michael Vissers
The next generation of cryogenic CMB and submillimeter cameras under development require densely instrumented sensor arrays to meet their science goals. The readout of large numbers (~10,000-100,000 per camera) of sub-Kelvin sensors, for instance as proposed for the CMB-S4 experiment, will require substantial improvements in cold and warm readout techniques. To reduce the readout cost per sensor and integration complexity, efforts are presently focused on achieving higher multiplexing density while maintaining readout noise subdominant to intrinsic detector noise and presenting manageable thermal loads. Highly-multiplexed cold readout technologies in active development include Microwave Kinetic Inductance Sensors (MKIDs) and microwave rf-SQUIDs. Both exploit the high quality factors of superconducting microwave resonators to densely channelize sub-Kelvin sensors into the bandwidth of a microwave transmission line. In the case of microwave SQUID multiplexing, arrays of transition-edge sensors (TES) are multiplexed by coupling each TES to its own superconducting microwave resonator through an rf-SQUID. We present advancements in the development of a new warm readout system for microwave SQUID multiplexing, the SLAC Superconducting Microresonator RF electronics, or SMuRF, by adapting SLAC National Accelerator Laboratory's Advanced Telecommunications Computing Architecture (ATCA) FPGA Common Platform. SMuRF aims to read out 4000 microwave SQUID channels between 4 and 8 GHz per RF line. Each compact SMuRF system is built onto a single ATCA carrier blade. Daughter boards on the blade implement RF frequency-division multiplexing using FPGAs, fast DACs and ADCs, and an analog up- and down-conversion chain. The system reads out changes in flux in each resonator-coupled rf-SQUID by monitoring the change in the transmitted amplitude and frequency of RF tones produced at each resonator's fundamental frequency. The SMuRF system is unique in its ability to track each tone, minimizing the total RF power required to readout each resonator, thereby significantly reducing the linearity requirements on the cold and warm readout. Here, we present measurements of the readout noise and linearity of the first full SMuRF system, including a demonstration of closed-loop tone tracking on a 528 channel cryogenic microwave SQUID multiplexer. SMuRF is being explored as a potential readout solution for a number of future CMB projects including Simons Observatory, BICEP Array, CCAT-prime, Ali-CPT, and CMB-S4. In addition, parallel development of the platform is underway to adapt SMuRF to read out both MKID and fast X-ray TES calorimeter arrays.

1 January 2023 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
CYCyndia Yu
Cyndia Yu
ZAZeeshan Ahmed
Zeeshan Ahmed
JFJosef C. Frisch
Josef C. Frisch
SHShawn W. Henderson
Shawn W. Henderson
MSMax Silva-Feaver
Max Silva-Feaver
EYEdward Young
Edward Young
We describe the newest generation of the SLAC Microresonator RF (SMuRF) electronics, a warm digital control and readout system for microwave-frequency resonator-based cryogenic detector and multiplexer systems, such as microwave superconducting quantum interference device multiplexers (μmux) or microwave kinetic inductance detectors. Ultra-sensitive measurements in particle physics and astronomy increasingly rely on large arrays of cryogenic sensors, which in turn necessitate highly multiplexed readout and accompanying room-temperature electronics. Microwave-frequency resonators are a popular tool for cryogenic multiplexing, with the potential to multiplex thousands of detector channels on one readout line. The SMuRF system provides the capability for reading out up to 3328 channels across a 4–8 GHz bandwidth. Notably, the SMuRF system is unique in its implementation of a closed-loop tone-tracking algorithm that minimizes RF power transmitted to the cold amplifier, substantially relaxing system linearity requirements and effective noise from intermodulation products. Here, we present a description of the hardware, firmware, and software systems of the SMuRF electronics, comparing achieved performance with science-driven design requirements. In particular, we focus on the case of large-channel-count, low-bandwidth applications, but the system has been easily reconfigured for high-bandwidth applications. The system described here has been successfully deployed in lab settings and field sites around the world and is baselined for use on upcoming large-scale observatories.

3 August 2022 in Journal of Low Temperature Physics
Verified
Journal Article
Closed access
PDF file
CYC. Yu
C. Yu
ZAZ. Ahmed
Z. Ahmed
JCJ. A. Connors
J. A. Connors
JDJ. M. D’eWart
J. M. D’eWart
BDB. Dober
B. Dober
EYE. Young
E. Young