Julian Martinez

Julian Martinez

Auto-generated profile, based on publicly available information

Julian Martinez

Zilber College of Public Health, University of Wisconsin-Milwaukee, Milwaukee, WI 53211, USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2023 in Journal for the Measurement of Physical Behaviour
Verified
Journal Article
Open access
PDF file
SKSarah K Keadle
Sarah K Keadle
JMJulian Martinez
Julian Martinez
SSScott J. Strath
Scott J. Strath
JSJohn Sirard
John Sirard
DJDinesh John
Dinesh John
JSJohn W. Staudemayer
John W. Staudemayer
Direct observation (DO) is a widely accepted ground-truth measure, but the field lacks standard operational definitions. Research groups develop project-specific annotation platforms, limiting the utility of DO if labels are not consistent. Purpose: The purpose was to evaluate within- and between-site agreement for DO taxonomies (e.g., activity intensity category) across four independent research groups who have used video-recorded DO. Methods: Each site contributed video files (508 min) and had two trained research assistants annotate the shared video files according to their existing annotation protocols. The authors calculated (a) within-site agreement for the two coders at the same site expressed as intraclass correlation and (b) between-site agreement, the proportion of seconds that agree between any two coders regardless of site. Results: Within-site agreement at all sites was good–excellent for both activity intensity categories (intraclass correlation range: .82–.9) and posture/whole-body movement (intraclass correlation range: .77–.98). Between-site agreement for intensity categories was 94.6% for sedentary, 80.9% for light, and 82.8% for moderate–vigorous. Three of the four sites had common labels for eight posture/whole-body movements and had within-site agreements of 94.5% and between-site agreements of 86.1%. Conclusions: Distinct research groups can annotate key features of physical behavior with good-to-excellent interrater reliability. Operational definitions are provided for core metrics for researchers to consider in future studies to facilitate between-study comparisons and data pooling, enabling the deployment of deep learning approaches to wearable device algorithm calibration.

1 March 2021 in Journal for the Measurement of Physical Behaviour
Verified
Journal Article
Closed access
PDF file
JMJulian Martinez
Julian Martinez
ADAutumn E. Decker
Autumn E. Decker
CCChi C. Cho
Chi C. Cho
ADAiden Doherty
Aiden Doherty
ASAnn M. Swartz
Ann M. Swartz
SSScott J. Strath
Scott J. Strath
Purpose: To assess the convergent validity of body-worn wearable camera still images (IMGs) for determining posture compared with activPAL (AP) classifications. Methods: The participants (n = 16, mean age 46.7 ± 23.8 years, 9 F) wore an Autographer wearable camera and an AP during three 2-hr free-living visits. IMGs were on average 8.47 s apart and were annotated with output consisting of events, transitory states, unknown, and gaps. The events were annotations that matched AP classifications (sit, stand, and move), consisting of at least three IMGs; the transitory states were posture annotations fewer than three IMGs; the unknowns were IMGs that could not be accurately classified; and the gaps were the time between annotations. For the analyses, the annotation and AP output were converted to 1-s epochs. The total and average length of visits and events were reported in minutes. Bias and 95% confidence intervals for event posture times from IMGs to AP were calculated to determine accuracy and precision. Confusion matrices using total AP posture times were computed to determine misclassification. Results: Forty-three visits were analyzed, with a total visit and event time of 5,027.73 and 4,237.23 min, respectively, and the average visit and event lengths being 116.92 and 98.54 min, respectively. Bias was not statistically significant for sitting, but was significant for standing and movement (0.84, −6.87, and 6.04 min, respectively). From confusion matrices, IMGs correctly classified sitting, standing, and movement (85.69%, 54.87%, and 69.41%, respectively) of total AP time. Conclusion: Wearable camera IMGs provide a good estimation of overall sitting time. Future work is warranted to improve posture classifications and examine the validity of IMGs in assessing activity-type behaviors.

8 April 2024 in Sensors
Verified
Journal Article
Open access
PDF file
SKSarah K Keadle
Sarah K Keadle
SESkylar Eglowski
Skylar Eglowski
KYKatie Ylarregui
Katie Ylarregui
SSScott Strath
Scott Strath
JMJulian Martinez
Julian Martinez
VKVadim Kagan
Vadim Kagan
Direct observation is a ground-truth measure for physical behavior, but the high cost limits widespread use. The purpose of this study was to develop and test machine learning methods to recognize aspects of physical behavior and location from videos of human movement: Adults (N = 26, aged 18–59 y) were recorded in their natural environment for two, 2- to 3-h sessions. Trained research assistants annotated videos using commercially available software including the following taxonomies: (1) sedentary versus non-sedentary (two classes); (2) activity type (four classes: sedentary, walking, running, and mixed movement); and (3) activity intensity (four classes: sedentary, light, moderate, and vigorous). Four machine learning approaches were trained and evaluated for each taxonomy. Models were trained on 80% of the videos, validated on 10%, and final accuracy is reported on the remaining 10% of the videos not used in training. Overall accuracy was as follows: 87.4% for Taxonomy 1, 63.1% for Taxonomy 2, and 68.6% for Taxonomy 3. This study shows it is possible to use computer vision to annotate aspects of physical behavior, speeding up the time and reducing labor required for direct observation. Future research should test these machine learning models on larger, independent datasets and take advantage of analysis of video fragments, rather than individual still images.

Verified
Journal Article
Open access
PDF file
GSGarrett Michael Steinbrink
Garrett Michael Steinbrink
JMJulian Martinez
Julian Martinez
ASAnn M. Swartz
Ann M. Swartz
SSScott Strath
Scott Strath
With a growing aging population, the routine assessment of physical function may become a critical component of clinical practice. The purpose of this cross-sectional study is to compare two common assessments of muscular function: (1) isometric knee extension strength (KES) and (2) sit-to-stand (STS) muscle power tests, in predicting objective physical function (i.e., gait speed) in aging adults. 84 adults (56% female, mean (SD) age = 66.6 (9.4) years) had their relative KES, STS power, usual gait speed (UGS), and fast gait speed (FGS) assessed. Multiple linear regression examined the associations between KES, STS power, and gait outcomes. When entered in separate models, KES and STS power were both independently associated with UGS and FGS (Std. β = 0.35–0.44 and 0.42–0.55 for KES and STS power, respectively). When entered in the same model, STS power was associated with UGS and FGS (Std. β = 0.37 [95%CI: 0.15, 0.58] and 0.51 [95%CI: 0.31, 0.70], respectively), while KES was only associated with FGS (Std. β = 0.25 [95%CI: 0.02, 0.48]). STS power seems to be a valid indicator of function in aging adults. Its feasibility as a screening tool for “low” function in the primary care setting should be explored.

1 January 2025 in Journal for the Measurement of Physical Behaviour
Verified
Journal Article
Closed access
JMJulian Martinez
Julian Martinez
GSGarrett Michael Steinbrink
Garrett Michael Steinbrink
RKRohit J. Kate
Rohit J. Kate
CCChi C. Cho
Chi C. Cho
ASAnn M. Swartz
Ann M. Swartz
SSScott J. Strath
Scott J. Strath
Physical activity (PA) and sedentary behavior (SB) are deeply ingrained within everyday life. It is important to capture all dimensions of PA and SB given their impact on health where the ideal measurement tool is able to measure the frequency, intensity, duration, and type of PA and SB when they occur. Media from wearable cameras (WCs) have seen increased use within the scientific literature for capturing health behavior, but their use for capturing PA and SB has not been systematically reviewed before. Therefore, the purpose of this scoping review was to determine the extent of WC media use for detailing PA and SB. A variety of record types from seven databases was searched from database inception to November 2023. Seventy-four sources were included, with purposes of WC media for capturing PA and SB for first-person activity recognition, to provide primary or secondary study outcome measures to be used as the ground truth measure for other measurement tools and for validation of WC media estimates of PA and SB. Both still images and video from WCs were used to capture the frequency, intensity, and duration of PA and SB, with 100% of included sources using WC media to capture types of PA and SB. Despite the extensive use of WC media to capture PA and SB, few studies have rigorously established the concurrent validity of WC media estimations of PA and SB against gold-standard measures, and participant characteristics within the first-person activity recognition field are seldom reported.

12 January 2022 in Journal of Physical Medicine and Rehabilitation
Verified
Journal Article
Open access
PDF file
JMJulian Martinez
Julian Martinez
TGTaylor M. Gordon
Taylor M. Gordon
SSScott J. Strath
Scott J. Strath
Functionally limiting health conditions have a high rate of prevalence worldwide and incur a significant amount of economic burden. Physical activity (PA) can prevent the onset of these conditions and alleviate economic burden by reducing symptoms, but a large portion of these individuals do not engage in health enhancing PA. Consumer wearable physical activity monitors (WPAM) are tools that have become increasingly popular within the past few years and could provide a means to improve PA levels for individuals with health conditions that cause functional limitations. This review reports on the validity of PA outcomes, feasibility and utility, and intervention/promotion effectiveness for consumer WPAM in functionally limited clinical populations. 2250 records from January 2018 to July 2021 were retrieved from PubMed, Web of Science, SPORTDiscus and CINAHL with 656 records being duplicates and 23 records passing a full-text article review. Studies included within the review looked at individuals with osteoarthritis, rheumatoid arthritis, axial spondyloarthritis, multiple sclerosis, Parkinson’s disease, ischemic stroke and peripheral arterial disease. The most popular brand of consumer WPAM was Fitbit. Validation studies for consumer WPAM were primarily focused on step counts showing overestimations for daily step counts and over- and under-estimations occurring within shorter time durations depending on step cadence. Wrist worn WPAM are the most feasible for functionally limited clinical populations with widespread utilization for associating clinically relevant outcomes with PA levels but they have limited validation to confirm their accuracy and precision in measurement. Interventions included used a mixture of a WPAM and other behavior change techniques to improve PA levels for clinical populations and show promising effectiveness. Future work is warranted on determining the validity of PA outcomes from WPAM determined to be feasible in select clinical populations and creating interventions looking at which features of a consumer WPAM intervention promote PA.