Zhongyi Chen

Zhongyi Chen

Auto-generated profile, based on publicly available information

Zhongyi Chen

Department of Orthopedics, Taizhou Hospital of Zhejiang Province, Affiliated to Wenzhou Medical University, Linhai City, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 January 2024 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
YYYang Yang
Yang Yang
LJLingjun Jiang
Lingjun Jiang
XZXiaoxiao Zhou
Xiaoxiao Zhou
XZXiaobo Zhou
Xiaobo Zhou
HCHaixiao Chen
Haixiao Chen
ZCZhongyi Chen
Zhongyi Chen
Purpose: Robotic-assisted total knee arthroplasty (r-TKA) facilitates precise bone resection and lower limb alignment, yet accuracy and functional recovery for severe varus/valgus deformity is not well-documented. The aim of study was to investigate whether r-TKA improves implant alignment in the coronal and sagittal view and early functional recovery compared to conventional TKA(c-TKA). Methods: This comparative study included 86 patients with symptomatic knee arthritis who underwent primary TKA at our institution between 1st May and 31th November 2021. Radiological parameters evaluated included hip-knee-ankle angle (HKAA), femoral varus-valgus angle (FVVA), tibial varus-valgus angle (TVVA), posterior tibial slope angle (PTSA), femoral sagittal angle (FSA), posterior condylar offset ratio, and Insall-Salvati index. Operative time, stay length, and complications were reviewed from patient records. The hospital for special surgery (HSS), Visual Analogue Scale (VAS) and knee joint motion range were evaluated at the six-month follow-up. Results: The c-TKA and r-TKA groups had no significant differences in HKAA (179.73 ± 3.76°, range: 172.10-188.90° vs. 180.53 ± 2.91°, range: 173.30-188.32°, p = 0.277), FVVA (96.13 ± 2.61°, range: 90.27-101.52° vs. 96.38 ± 2.23°, range: 90.98-100.95°, p = 0.636), and TVVA (88.74 ± 2.03°, range: 83.75–92.74° vs. 89.43 ± 1.83°, range: 85.32–94.15°, p = 1.000). Outlier of mechanical alignment incidence (> 3°) was significantly lower in r-TKA compared with c-TKA, 17.50% (7/40) vs. 41.30% (19/46), (p = 0.017). PTSA of r-TKA remained significantly lower than c-TKA (p = 0.009) in mild-deformity patients. For severe varus/valgus deformity, r-TKA had a significantly lesser HKAA-outlier incidence (p = 0.025), PTSA-outlier incidence (p = 0.019), and lower PTSA (p < 0.001) compared with c-TKA. The r-TKA functional outcome was better than c-TKA regarding HSS (93.12 ± 1.97, range: 90–95, 95%CI:92.11–94.13 vs. 91.33 ± 2.50, range: 85–95, 95%CI:90.20-92.69, p = 0.036), and VAS (0.24 ± 0.44, range:0–1 vs. 0.72 ± 0.75, range:0–2, p = 0.026), knee joint flexion (118.53° ± 8.06, range: 105–130°, 95%CI:114.39-122.67° vs. 112.22 ± 8.09°, range: 100–130°, 95%CI:108.20-116.24° ,p = 0.027) for severe varus/valgus deformity. Conclusion: r-TKA improved lower-limb coronal alignment, sagittal implant position, and early functional recovery for patients with severe varus/valgus deformity of the knee. r-TKA did not confer substantial advantages over c-TKA in both radiological and clinical outcomes for the mild varus/valgus deformity.

31 August 2021 in Research Square
Verified
Preprint
Open access
PDF file
JYJiajing Ye
Jiajing Ye
ZZZhong Zhu
Zhong Zhu
LJLingjun Jiang
Lingjun Jiang
HWHaizhao Wu
Haizhao Wu
SWShouli Wang
Shouli Wang
ZCZhongyi Chen
Zhongyi Chen
Background: This study evaluates the effects of wire tension band ventral compression wiring technology paired with artificial femoral head replacement according to the different types of intertrochanteric fractures of the greater trochanter in elderly patients. Methods: Thirty-eight patients with unstable intertrochanteric fractures of the femur treated with artificial femoral head replacement between January 2015 and August 2019 were included. According to the fracture line of the greater trochanter, a new classification system was proposed. Type A fractures include transverse fractures from the greater trochanter tip to the base (2 patients). Type B fractures include oblique fractures from the greater trochanter tip to the base (according to the fracture line direction, type B was further divided into types B1 [4 patients], and B2 [24 patients]). the fracture line of type C fractures runs from the greater trochanter to near the femur end (8 patients). Different wire tension belt ventral compression wiring technologies were used for each fracture type. The Harris hip function score, Parker activity score, and hip pain were evaluated during the follow-up period. Fracture healing and prosthesis positioning, loosening, and dislocation were evaluated using radiographs. Results: The average follow-up period was 28.6 ± 5.8 months. Deep vein embolism was noted in one patient, heterotopic ossification in another, and steel wire fractures in another. All patients had satisfactory fracture healing and femoral prosthesis positioning and no chronic pain. The mean Harris hip function score was 7.21 ± 2.58 preoperatively and 84.74 ± 3.82 at the final follow-up (F = -48.13, P < 0.001).Conclusion: The use of different wire tension band ventral compression wiring technology based on different types of femoral rotation fractures combined with artificial femoral head replacement in elderly patients with unstable intertrochanteric fractures results in favorable clinical outcomes.