Susumu Katsushika

Susumu Katsushika

Auto-generated profile, based on publicly available information

Susumu Katsushika

Department of Cardiovascular Medicine, The University of Tokyo Hospital , 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655 , Japan

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2022 in Journal of Cardiology
Verified
Journal Article
Open access
SSShinnosuke Sawano
Shinnosuke Sawano
SKSatoshi Kodera
Satoshi Kodera
SKSusumu Katsushika
Susumu Katsushika
MNMitsuhiko Nakamoto
Mitsuhiko Nakamoto
KNKota Ninomiya
Kota Ninomiya
IKIssei Komuro
Issei Komuro
Aortic regurgitation (AR) is a common heart disease, with a relatively high prevalence of 4.9% in the Framingham Heart Study. Because the prevalence increases with advancing age, an upward shift in the age distribution may increase the burden of AR. To provide an effective screening method for AR, we developed a deep learning-based artificial intelligence algorithm for the diagnosis of significant AR using electrocardiography (ECG). Our dataset comprised 29,859 paired data of ECG and echocardiography, including 412 AR cases, from January 2015 to December 2019. This dataset was divided into training, validation, and test datasets. We developed a multi-input neural network model, which comprised a two-dimensional convolutional neural network (2D-CNN) using raw ECG data and a fully connected deep neural network (FC-DNN) using ECG features, and compared its performance with the performances of a 2D-CNN model and other machine learning models. In addition, we used gradient-weighted class activation mapping (Grad-CAM) to identify which parts of ECG waveforms had the most effect on algorithm decision making. The area under the receiver operating characteristic curve of the multi-input model (0.802; 95% CI, 0.762-0.837) was significantly greater than that of the 2D-CNN model alone (0.734; 95% CI, 0.679-0.783; p<0.001) and those of other machine learning models. Grad-CAM demonstrated that the multi-input model tended to focus on the QRS complex in leads I and aVL when detecting AR. The multi-input deep learning model using 12-lead ECG data could detect significant AR with modest predictive value.

5 August 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
HSHiroki Shinohara
Hiroki Shinohara
SKSatoshi Kodera
Satoshi Kodera
KNKota Ninomiya
Kota Ninomiya
MNMitsuhiko Nakamoto
Mitsuhiko Nakamoto
SKSusumu Katsushika
Susumu Katsushika
IKIssei Komuro
Issei Komuro
Intravascular ultrasound (IVUS) is a diagnostic modality used during percutaneous coronary intervention. However, specialist skills are required to interpret IVUS images. To address this issue, we developed a new artificial intelligence (AI) program that categorizes vessel components, including calcification and stents, seen in IVUS images of complex lesions. When developing our AI using U-Net, IVUS images were taken from patients with angina pectoris and were manually segmented into the following categories: lumen area, medial plus plaque area, calcification, and stent. To evaluate our AI’s performance, we calculated the classification accuracy of vessel components in IVUS images of vessels with clinically significantly narrowed lumina (< 4 mm2) and those with severe calcification. Additionally, we assessed the correlation between lumen areas in manually-labeled ground truth images and those in AI-predicted images, the mean intersection over union (IoU) of a test set, and the recall score for detecting stent struts in each IVUS image in which a stent was present in the test set. Among 3738 labeled images, 323 were randomly selected for use as a test set. The remaining 3415 images were used for training. The classification accuracies for vessels with significantly narrowed lumina and those with severe calcification were 0.97 and 0.98, respectively. Additionally, there was a significant correlation in the lumen area between the ground truth images and the predicted images (ρ = 0.97, R2 = 0.97, p < 0.001). However, the mean IoU of the test set was 0.66 and the recall score for detecting stent struts was 0.64. Our AI program accurately classified vessels requiring treatment and vessel components, except for stents in IVUS images of complex lesions. AI may be a powerful tool for assisting in the interpretation of IVUS imaging and could promote the popularization of IVUS-guided percutaneous coronary intervention in a clinical setting.

17 April 2023 in European Heart Journal - Digital Health
Verified
Journal Article
Open access
PDF file
SKSusumu Katsushika
Susumu Katsushika
SKSatoshi Kodera
Satoshi Kodera
SSShinnosuke Sawano
Shinnosuke Sawano
HSHiroki Shinohara
Hiroki Shinohara
NSNaoto Setoguchi
Naoto Setoguchi
IKIssei Komuro
Issei Komuro
Aims: The black box nature of artificial intelligence (AI) hinders the development of interpretable AI models that are applicable in clinical practice. We aimed to develop an AI model for classifying patients of reduced left ventricular ejection fraction (LVEF) from 12-lead electrocardiograms (ECG) with the decision-interpretability. Methods and results: We acquired paired ECG and echocardiography datasets from the central and co-operative institutions. For the central institution dataset, a random forest model was trained to identify patients with reduced LVEF among 29 907 ECGs. Shapley additive explanations were applied to 7196 ECGs. To extract the model’s decision criteria, the calculated Shapley additive explanations values were clustered for 192 non-paced rhythm patients in which reduced LVEF was predicted. Although the extracted criteria were different for each cluster, these criteria generally comprised a combination of six ECG findings: negative T-wave inversion in I/V5–6 leads, low voltage in I/II/V4–6 leads, Q wave in V3–6 leads, ventricular activation time prolongation in I/V5–6 leads, S-wave prolongation in V2–3 leads, and corrected QT interval prolongation. Similarly, for the co-operative institution dataset, the extracted criteria comprised a combination of the same six ECG findings. Furthermore, the accuracy of seven cardiologists’ ECG readings improved significantly after watching a video explaining the interpretation of these criteria (before, 62.9% ± 3.9% vs. after, 73.9% ± 2.4%; P = 0.02). Conclusion: We visually interpreted the model’s decision criteria to evaluate its validity, thereby developing a model that provided the decision-interpretability required for clinical application.

31 July 2019 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Closed access
SKSusumu Katsushika
Susumu Katsushika
MKMikio Kishi
Mikio Kishi
TSTakahiro Sato
Takahiro Sato
MMMasashiro Matsushita
Masashiro Matsushita
MYMasao Yamasaki
Masao Yamasaki