Richard W. Malham

Richard W. Malham

Auto-generated profile, based on publicly available information

Richard W. Malham

Astbury Centre for Structural Molecular Biology, University of Leeds, LS2 9JT, UK

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2009 in European Journal of Mass Spectrometry
Verified
Journal Article
Closed access
DSDavid Smith
David Smith
TKTom W. Knapman
Tom W. Knapman
ICIain Campuzano
Iain Campuzano
RMRichard W. Malham
Richard W. Malham
JBJoshua T. Berryman
Joshua T. Berryman
AAAlison E. Ashcroft
Alison E. Ashcroft
Detailed knowledge of the tertiary and quaternary structure of proteins and protein complexes is of immense importance in understanding their functionality. Similarly, variations in the conformational states of proteins form the underlying mechanisms behind many biomolecular processes, numerous of which are disease-related. Thus, the availability of reliable and accurate biophysical techniques that can provide detailed information concerning these issues is of paramount importance. Ion mobility spectrometry (IMS) coupled to mass spectrometry (MS) offers a unique opportunity to separate multi-component biomolecular entities and to measure the molecular mass and collision cross-section of individual components in a single, rapid (≤ 2 min) experiment, providing 3D-architectural information directly. Here we report a method of calibrating a commercially available electrospray ionisation (ESI)-travelling wave ion mobility spectrometry (TWIMS)–mass spectrometer using known cross-sectional areas determined for a range of biomolecules by conventional IMS-MS. Using this method of calibration, we have analysed a range of proteins of differing mass and 3D architecture in their native conformations by ESI-TWIMS-MS and found that the cross-sectional areas measured in this way compare extremely favourably with cross-sectional areas calculated using an in-house computing method based on Protein Data Bank NMR-derived co-ordinates. This not only provides a high degree of confidence in the calibration method, but also suggests that the gas phase ESI-TWIMS-MS measurements relate well to solution-based measurements derived from other biophysical techniques. In order to determine which instrumental parameters affect the ESI-TWIMS-MS cross-sectional area calibration, a systematic study of the parameters used to optimise TWIMS drift time separations has been carried out, observing the effect each parameter has on drift times and IMS resolution. Finally, the ESI-TWIMS-MS cross-sectional area calibration has been applied to the analysis of the amyloidogenic protein β2-microglobulin and measurements for three co-populated conformational families, present under denaturing conditions, have been made: the folded, partially unfolded and unfolded states.

11 November 2005 in Journal of the American Chemical Society
Verified
Journal Article
Closed access
RMRichard Malham
Richard Malham
SJSarah Johnstone
Sarah Johnstone
RBRichard Bingham
Richard Bingham
EBElizabeth Barratt
Elizabeth Barratt
SPSimon E. V. Phillips
Simon E. V. Phillips
SHSteve W. Homans
Steve W. Homans

1 September 2013
Verified
Conference Paper
Closed access
KTK.M. Tych
K.M. Tych
ABAndrew D. Burnett
Andrew D. Burnett
CWChristopher Wood
Christopher Wood
RMRichard W. Malham
Richard W. Malham
LLLianhe Li
Lianhe Li
ADA. Giles Davies
A. Giles Davies
Broadband time-domain spectroscopy was used to measure the terahertz frequency absorption of protein single crystals in order to study global protein dynamics. Temperature dependent dynamics were measured for lysozyme, and the terahertz frequency spectrum of mouse urinary protein was compared to calculated spectra.