Timothy W.I. Clark

Timothy W.I. Clark

Auto-generated profile, based on publicly available information

Timothy W.I. Clark

Section of Interventional Radiology, Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, USA

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2001 in Journal of Vascular and Interventional Radiology
Verified
Journal Article
Closed access
TCTimothy W.I. Clark
Timothy W.I. Clark
JGJeffrey L. Groffsky
Jeffrey L. Groffsky
MSMichael C. Soulen
Michael C. Soulen

31 July 2007 in Journal of Vascular and Interventional Radiology
Verified
Journal Article
Closed access
ARAlexander T. Ruutiainen
Alexander T. Ruutiainen
MSMichael C. Soulen
Michael C. Soulen
CTCatherine M. Tuite
Catherine M. Tuite
TCTimothy W.I. Clark
Timothy W.I. Clark
JMJeffrey I. Mondschein
Jeffrey I. Mondschein
STScott O. Trerotola
Scott O. Trerotola

1 December 2015 in Journal of Vascular and Interventional Radiology
Verified
Journal Article
Closed access
LTLisa M. Tom
Lisa M. Tom
HPHarold I. Palevsky
Harold I. Palevsky
DHDouglas S. Holsclaw
Douglas S. Holsclaw
STScott O. Trerotola
Scott O. Trerotola
MDMandeep Dagli
Mandeep Dagli
TCTimothy W.I. Clark
Timothy W.I. Clark

1 February 2015 in Journal of Vascular and Interventional Radiology
Verified
Journal Article
Open access
TCTimothy W.I. Clark
Timothy W.I. Clark
GIGiuseppe Isu
Giuseppe Isu
DGDiego Gallo
Diego Gallo
PVPascal Verdonck
Pascal Verdonck
Umberto MorbiducciUmberto Morbiducci
Umberto Morbiducci
Symmetric-tip dialysis catheters have become alternative devices because of low access recirculation and ease of tip positioning. Flow characteristics of three symmetric catheters were compared based on computational fluid dynamics (CFD) as they relate to catheter function. In Palindrome, GlidePath, and VectorFlow catheters, a computational fluid dynamics-based approach was used to assess (i) regions of flow separation, which are prone to thrombus development; (ii) shear-induced platelet activation potency; (iii) recirculation; and (iv) venous outflow deflection. A steady-state, laminar flow model simulated catheter tip position within the superior vena cava. Catheter performance was investigated at high hemodialysis flow rate (400 mL/min). Blood was assumed as a Newtonian fluid. Wide regions of flow separation downstream of the Palindrome side slot and close to the distal tip were observed in forward and reversed line configurations. Geometric asymmetry of the distal guide wire aperture of the GlidePath catheter produced the highest levels of inverted velocity flow when run in reversed configuration. The lowest mean shear-induced platelet activation was exhibited by GlidePath and VectorFlow catheters; the Palindrome catheter exhibited 152% higher overall platelet activation potency. All catheters were associated with a recirculation close to zero; the helically contoured lumens of the VectorFlow catheter produced the greatest amount of deflection of venous flow away from the arterial lumen. The VectorFlow catheter produced less shear-induced platelet activation than the Palindrome catheter and less flow separation than the Palindrome and GlidePath catheters irrespective of line configuration. These findings have potential implications for differences in thrombogenic risk during clinical performance of these catheters.

1 May 2003 in Journal of Vascular and Interventional Radiology
Verified
Journal Article
Closed access
PDF file
TCTimothy W.I. Clark
Timothy W.I. Clark

1 September 2002 in Journal of Vascular and Interventional Radiology
Verified
Journal Article
Closed access
TCTimothy W.I. Clark
Timothy W.I. Clark
MSMichael C. Soulen
Michael C. Soulen