Andres Mena

Andres Mena

Auto-generated profile, based on publicly available information

Andres Mena

Universidad de Zaragoza

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 November 2012 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
MMM. Malvè
M. Malvè
SCS. Chandra
S. Chandra
AGAlberto García
Alberto García
AMA. Mena
A. Mena
MMM.A. Martínez
M.A. Martínez
MDM. Doblaré
M. Doblaré
In this study, we develop structured tree outflow boundary conditions for modelling the human carotid haemodynamics. The model geometry was reconstructed through computerised tomography scan. Unsteady-state computational fluid dynamic analyses were performed under different conditions using a commercial software package ADINA R&D, Inc., (Watertown, MA, USA) in order to assess the impact of the boundary conditions on the flow variables. In particular, the results showed that the peripheral vessels massively impact the pressure while the flow is relatively unaffected. As an example of application of these outflow conditions, an unsteady fluid-structure interaction (FSI) simulation was carried out and the dependence of the wall shear stress (WSS) on the arterial wall compliance in the carotid bifurcation was studied. In particular, a comparison between FSI and rigid-wall models was conducted. Results showed that the WSS distributions were substantially affected by the diameter variation of the arterial wall. In particular, even similar WSS distributions were found for both cases, and differences in the computed WSS values were also found.

5 January 2011 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
MMM. Malvè
M. Malvè
APAmaya Perez del Palomar
Amaya Perez del Palomar
SCS. Chandra
S. Chandra
JLJ. L. López-Villalobos
J. L. López-Villalobos
AMA. Mena
A. Mena
MDM. Doblaré
M. Doblaré
In this work, a fluid-solid interaction (FSI) analysis of a healthy and a stenotic human trachea was studied to evaluate flow patterns, wall stresses, and deformations under physiological and pathological conditions. The two analyzed tracheal geometries, which include the first bifurcation after the carina, were obtained from computed tomography images of healthy and diseased patients, respectively. A finite element-based commercial software code was used to perform the simulations. The tracheal wall was modeled as a fiber reinforced hyperelastic solid material in which the anisotropy due to the orientation of the fibers was introduced. Impedance-based pressure waveforms were computed using a method developed for the cardiovascular system, where the resistance of the respiratory system was calculated taking into account the entire bronchial tree, modeled as binary fractal network. Intratracheal flow patterns and tracheal wall deformation were analyzed under different scenarios. The simulations show the possibility of predicting, with FSI computations, flow and wall behavior for healthy and pathological tracheas. The computational modeling procedure presented herein can be a useful tool capable of evaluating quantities that cannot be assessed in vivo, such as wall stresses, pressure drop, and flow patterns, and to derive parameters that could help clinical decisions and improve surgical outcomes.

1 August 2011 in International Communications in Heat and Mass Transfer
Verified
Journal Article
Closed access
MMM. Malvè
M. Malvè
APAmaya Perez del Palomar
Amaya Perez del Palomar
AMA. Mena
A. Mena
Olfa TrabelsiOlfa Trabelsi
Olfa Trabelsi
JLJ.L. López-Villalobos
J.L. López-Villalobos
MDM. Doblaré
M. Doblaré

1 November 2015 in Computer Physics Communications
Verified
Journal Article
Closed access
AMAndres Mena
Andres Mena
JFJose M. Ferrero
Jose M. Ferrero
JMJose Felix Rodriguez Matas
Jose Felix Rodriguez Matas

28 June 2010 in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
Verified
Journal Article
Closed access
PDF file
APAmaya Perez del Palomar
Amaya Perez del Palomar
Olfa TrabelsiOlfa Trabelsi
Olfa Trabelsi
AMA. Mena
A. Mena
JLJ. L. López-Villalobos
J. L. López-Villalobos
AGA. Ginel
A. Ginel
MDM. Doblaré
M. Doblaré
Nowadays, interventions associated with the implantation of tracheal prostheses in patients with airway pathologies are very common. This surgery may promote problems such as migration of the prosthesis, development of granulation tissue at the edges of the stent with overgrowth of the tracheal lumen or accumulation of secretions inside the prosthesis. Among the movements that the trachea carries out, swallowing seems to have harmful consequences for the tracheal tissues surrounding the prosthesis. In this work, a finite-element-based tool is presented to construct patient-specific tracheal models, introducing the endotracheal prosthesis and analysing the mechanical consequences of this surgery during swallowing. A complete description of a patient-specific tracheal model is given, and a fully experimental characterization of the tracheal tissues is presented. To construct patient-specific grids, a mesh adaptation algorithm has been developed and the implantation of a tracheal prosthesis is simulated. The ascending deglutition movement of the trachea is recorded using real data from each specific patient from fluoroscopic images before and after implantation. The overall behaviour of the trachea is modified when a prosthesis is introduced. The presented tool has been particularized for two different patients (patient A and patient B), allowing prediction of the consequences of this kind of surgery. In particular, patient A had a decrease of almost 30 per cent in his ability to swallow, and an increase in stresses that were three times higher after prosthesis implantation. In contrast, patient B, who had a shorter trachea and who seemed to undergo more damaging effects, did not have a significant reduction in his ability to swallow and did not present an increase in stress in the tissues. In both cases, there are clinical studies that validate our results: namely, patient A underwent a further intervention whereas the outcome of patient B’s surgery was completely successful. Notwithstanding the fact that there are a lot of uncertainties relating to the implantation of endotracheal prostheses, the present work gives a new insight into these procedures, predicting their mechanical consequences. This tool could be used in the future as pre-operative planning software to help thoracic surgeons in deciding the optimal prosthesis as well as its size and positioning.

31 October 2011 in Applied Mathematical Modelling
Verified
Journal Article
Closed access
Olfa TrabelsiOlfa Trabelsi
Olfa Trabelsi
APAmaya Perez del Palomar
Amaya Perez del Palomar
ATA. Mena Tobar
A. Mena Tobar
JLJ.L. López-Villalobos
J.L. López-Villalobos
AGA. Ginel
A. Ginel
MDM. Doblaré
M. Doblaré