Changling Li

Changling Li

Auto-generated profile, based on publicly available information

Changling Li

Swiss Light Source, Paul Scherrer Institute, Villigen, Switzerland; Department of Otorhinolaryngology, Head and Neck Surgery, CHUV Centre Hospitalier Universitaire Vaudois and University of Lausanne, Lausanne, Switzerland; The Sense Innovation and Research Center, Lausanne and Sion, Lausanne, Switzerland

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 December 2025 in Hearing Research
Verified
Journal Article
Open access
GRGriffin Rodgers
Griffin Rodgers
CLCecilia Lotto
Cecilia Lotto
CLChangling Li
Changling Li
MSMargaux Schmeltz
Margaux Schmeltz
AIAleksandra Ivanovic
Aleksandra Ivanovic
ABAnne Bonnin
Anne Bonnin
Understanding middle ear biomechanics is crucial for clarifying sound transmission and surgical techniques. Conventional interferometry-based techniques for motion quantification are highly sensitive but are often limited to small surfaces, while conventional microtomography is volumetric but cannot adequately resolve soft tissues and temporal dynamics. We used dynamic synchrotron-based X-ray phase-contrast microtomography on three fresh-frozen human temporal bones under acoustic stimulation at 128, 256, and 512Hz with sound pressure levels of 120, 126, 141, and 151dB. This method achieved micrometer spatial and kHz temporal resolution, allowing 4D visualization of the ossicles and tympanic membrane (TM). Non-rigid registration quantified micrometer-scale TM motion and was validated with anatomical landmarks. Displacement 'hot spots' were consistently observed in the posterosuperior quadrant of the TM and the pars flaccida, although their relative contributions varied between specimens. Displacement amplitudes also varied strongly between specimens, with peaks ranging from <0.15 to nearly 2 μm/Pa. The magnitude of displacement changed with the level and frequency of the sound pressure, while the motion patterns remained stable. These findings demonstrate that dynamic synchrotron-based X-ray phase-contrast microtomography is a reliable and powerful approach for studying the non-rigid motion of TM. The variability between samples underscores the need for correlative imaging to characterize both motion and tissue microstructure such as fiber orientation and density. Future studies should also investigate how the motion of the TM correlates with the movement of the umbo and entire ossicular chain to provide a more complete understanding of the mechanics of the middle ear.