25 May 2023 in IEEE Access
The existing Overcurrent Protection Function (OCPF) of distribution systems is vulnerable to Multiple Feeder Faults (MFF), which involve at least two feeders simultaneously, leading to the incoming feeder relay trip faster than the faulted feeder relays, although the OCPF of the relays can be coordinated for all fault current values. In this case, all feeders connected to the power transformer are de-energized, even the healthy ones, directly impacting the network reliability, service quality and availability of the electricity utilities and ultimately leading to outage costs for the customers. In light of this, an IEC 61850-based OCPF scheme with the directional element is proposed to support existing OCPF to deal with MFF and encompass the integration of distributed generation, and can be directly implemented in the digital substations without requiring further equipment installation. Moreover, an hardware-in-the-loop platform is developed for testing the interoperability of the proposed scheme with multi-vendor protection relays, which can assist electricity utilities also in the validation of their protection and control schemes based on their requirements before the field implementation. Test cases are specifically elaborated to study the interoperability of the proposed scheme with three real devices—whose configuration details are also provided to aid protection engineers—in a real distribution system, under different conditions such as switching operations, MFF types, resistance and location, integration of distributed generation. The results show that the proposed scheme manages to enhance the selectivity and reliability of the digital substation protection system, hence representing a valuable complement to existing OCPF schemes.
19 February 2024 in IEEE Access
In modern power systems, testing protection systems and equipment before the field implementation is vital to ensure the correct operation and guarantee reliability, quality and security of electricity supply. This paper focuses on the performance testing of the distance protection, whose state-of-the-art test methodologies (including the recommendations of the IEC 60255-121:2014 standard) can quickly lead to time/money resource limitations. As budget-wise considerations cannot justify an “arbitrary” or “convenient” selection of which and how many tests to perform, this paper shows how the current testing methodologies benefits from the statistical design of experiments (stat-DOE). It is proven how the stat-DOE supports the performance testing in the efficient selection of the optimal tests to conduct, in the systematic investigation of the effect of different factors, and in the robust definition of pass/fail criteria for specifying acceptance tests. A step-to-step practical guideline for adopting the stat-DOE is offered to study a realistic performance testing, accounting for operator-specific requirements (e.g., maximum affordable number of tests) and physical constraints among factors. The results allow to propose lines of refinement and recommendations for the stakeholders. Finally, not only this paper serves as a guide to replicate the performance testing of other protection functions or in alternative scenarios, but it also ultimately paves the way for the routine adoption of the stat-DOE in the definition and refinement of test methodologies for power system protection testing at large towards the achievement of a standardized basis for it.