14 September 2015 in American Journal of Transplantation
Passenger leukocyte transfer from the donor lung to the recipient is intrinsically involved in acute rejection. Direct presentation of alloantigen expressed on donor leukocytes is recognized by recipient T cells, promoting acute cellular rejection. We utilized ex vivo lung perfusion (EVLP) to study passenger leukocyte migration from donor lungs into the recipient and to evaluate the effects of donor leukocyte depletion prior to transplantation. For this purpose, female pigs received male left lungs either following 3 h of EVLP or retrieved using standard protocols. Recipients were monitored for 24 h and sequential samples were collected. EVLP‐reduced donor leukocyte transfer into the recipient and migration to recipient lymph nodes was markedly reduced. Recipient T cell infiltration of the donor lung was significantly diminished via EVLP. Donor leukocyte removal during EVLP reduces direct allorecognition and T cell priming, diminishing recipient T cell infiltration, the hallmark of acute rejection.
1 May 2015 in Transplantation
Lung transplantation is limited by a scarcity of suitable donors resulting in high waiting list mortality. Ex vivo lung perfusion (EVLP) allows the evaluation and reconditioning of marginal donor lungs for use in transplantation. This study aimed to compare clinical outcome of patients transplanted with marginal organs by means of EVLP with a standard lung transplant cohort through a multicenter open trial. Group 1 (n = 9) included patients transplanted using EVLP reconditioned marginal lungs. Group 2 (n = 46) consisted of date-matched patients transplanted using standard transplantation of acceptable lungs. The primary composite endpoint included acute rejection and infection at 12 months after transplantation. There was no significant difference in the overall incidence of acute rejection (P = 0.754) and the number of treated infection episodes (proven/probable pneumonia; P = 0.857/0.368 and proven/probable tracheobronchitis; P = 0.226/0.529) up to 12 months after transplantation, between group 1 and group 2. Additionally, there was no significant difference in early clinical outcome, including intensive care unit stay, hospital stay, and 1 year mortality between the two groups (P = 0.338, P = 0.112 and P = 0.372, respectively). This multicenter study demonstrates that EVLP is associated with no adverse effect on clinical outcome, including the incidence of acute rejection and infection after lung transplantation.
1 November 2016 in Kidney International Reports
Ex vivo normothermic perfusion offers an alternative method of organ preservation, allowing donor kidneys to be reanimated and evaluated prior to transplantation. Beyond preservation, it can be used to characterize the immunological contribution of the donor kidney in isolation. Furthermore, it has the potential to be used as an immunomodulatory strategy to manipulate donor kidneys prior to transplantation. Explanted porcine kidneys underwent 6 hours of perfusion. Sequential perfusate samples were collected and leukocytes characterized via flow cytometry. An inflammatory profile was generated via cytokine quantification. Cell-free DNA was also determined as markers of cell death. All kidneys functioned within normal parameters and met the criteria for transplantation at the end of perfusion. Throughout perfusion there were continuous increases in pro-inflammatory cytokines, including large concentrations of interferon-γ, suggesting that perfusion drives a significant inflammatory response. Increasing concentrations in cell-free DNA were also observed, suggesting cell death. During perfusion there was a marked cellular diapedesis of T cells, B cells, natural killer (NK) cells, and monocytes from the kidney into the circuit. Minor populations of granulocytes and macrophages were also detected. We demonstrate that ex vivo normothermic perfusion initiates an inflammatory cytokine storm and release of mitochondrial and genomic DNA. This is likely to be responsible for immune cell activation and mobilization into the circuit prior to transplantation. Interestingly this did not have an impact on renal function. These data therefore suggest that normothermic perfusion can be used to immunodeplete and to saturate the pro-inflammatory capacity of donor kidneys prior to transplantation.
1 August 2014 in The Journal of Heart and Lung Transplantation
1 May 2021 in British Journal of Surgery
Background: Attempts to improve limb preservation for transplantation using ex vivo perfusion have yielded promising results. However, metabolic acidosis, aberrant perfusate biochemistry and significant perfusion-induced oedema are reported universally. Optimizing perfusion protocols is therefore essential for maintaining tissue health. Methods: A randomized, two-stage open preclinical trial design was used to determine the optimal temperature and mean arterial pressure for machine perfusion. Conditions compared were: normothermic machine perfusion at 70 mmHg (NMP-70); subnormothermic perfusion (28°C) at 70 mmHg; subnormothermic (28°C) perfusion at 50 mmHg; and hypothermic perfusion (10°C) at 30 mmHg. Following this, a head-to-head experiment was undertaken comparing the optimal machine perfusion with static cold storage. Paired bilateral limbs (10 in total) were randomized to either 8 h of static cold storage, or 2 h of static cold storage and 6 h of optimal machine perfusion. Both groups of limbs were then reperfused on a circuit primed with matched blood from unrelated donors for 4 h without immunosuppression. Results: NMP-70 resulted in less tissue injury and stable perfusion biochemistry. Assessing reperfusion outcomes, static cold storage resulted in acidosis with increased lactate and a worsening electrolyte profile, necessitating bolus infusions of bicarbonate to prevent graft loss. Conversely, NMP-70 was associated with haemodynamic and biochemical stability. Histologically, on reperfusion with allogeneic whole blood, limbs subjected to static cold storage exhibited multifocal ischaemic injury and increased inflammation, which was absent with NMP-70. Static cold storage also resulted in significant oedema compared with NMP-70. Conclusion: Normothermic perfusion resulted in superior graft preservation and less reperfusion injury compared with the current static cold storage protocol.
28 July 2020 in Frontiers in Immunology
Introduction: Many donor organs contain significant leukocyte reservoirs which upon transplantation activate recipient leukocytes to initiate acute rejection. We aimed to assess whether non-ischemic heart preservation via ex vivo perfusion promotes immunodepletion and alters the inflammatory status of the donor organ prior to transplantation. Methods: Isolated porcine hearts underwent ex vivo hypothermic, cardioplegic perfusion for 8 h. Leukocyte populations were quantified in left ventricle samples by flow cytometry. Cell-free DNA, cytokines, and chemokines were quantified in the perfusate. Tissue integrity was profiled by targeted proteomics and a histological assessment was performed. Heterotopic transplants comparing ex vivo hypothermic preservation and static cold storage were utilized to assess graft infiltration as a solid clinical endpoint. Results: Ex vivo perfusion significantly immunodepleted myocardial tissue. The perfusate displayed a selective, pro-inflammatory cytokine/chemokine pattern dominated by IFN-γ. The tissue molecular profile was improved following perfusion by diminished expression of nine pro-apoptotic and six ischemia-associated proteins. Histologically, no evidence of tissue damage was observed and cardiac troponin I was low throughout perfusion. Cell-free DNA was detected, the source of which may be necrotic/apoptotic leukocytes. Post-transplant graft infiltration was markedly reduced in terms of both leucocyte distribution and intensity of foci. Conclusions: These findings demonstrate that ex vivo perfusion significantly reduced donor heart immunogenicity via loss of resident leukocytes. Despite the pro-inflammatory cytokine pattern observed, a pro-survival and reduced ischemia-related profile was observed, indicating an improvement in graft viability by perfusion. Diminished graft infiltration was observed in perfused hearts compared with those preserved by static cold storage following 48 h of transplantation.