Michelle E. Tarver

Michelle E. Tarver

Auto-generated profile, based on publicly available information

Michelle E. Tarver

Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, USA

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2020 in Value in Health
Verified
Journal Article
Closed access
HBHeather L. Benz
Heather L. Benz
ASAnindita Saha
Anindita Saha
MTMichelle E. Tarver
Michelle E. Tarver

20 April 2022 in Journal of Patient-Reported Outcomes
Verified
Journal Article
Open access
PDF file
SMSophia T. Matts
Sophia T. Matts
CWChristina M. Webber
Christina M. Webber
FBFraser D. Bocell
Fraser D. Bocell
BCBrittany Caldwell
Brittany Caldwell
ACAllen L. Chen
Allen L. Chen
MTMichelle E. Tarver
Michelle E. Tarver
Background: The U.S. Food and Drug Administration encourages the incorporation of the patient voice throughout the medical device total product lifecycle. This study examined the incorporation of patient-reported outcome (PRO) instruments in the evaluation of medical devices over a six-year period. PRO instruments used to inform study endpoints were extracted from the summary documents and clinical trial data of premarket authorizations posted on publicly available FDA databases between October 1, 2014—September 30, 2020. Results: PROs were included in 53% of authorizations, with 34% using PROs as primary and secondary endpoints. This study found that PRO instruments were used in each type of marketing authorization and in all medical specialties examined in this study. Conclusions: Expanding the current collaborative efforts to develop and modify PRO instruments may help to improve use of PROs in medical device evaluations.

3 March 2021 in Clinical Journal of the American Society of Nephrology
Verified
Journal Article
Closed access
PDF file
MTMichelle E. Tarver
Michelle E. Tarver
CNCarolyn Neuland
Carolyn Neuland

9 November 2023 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
ALA. Noelle Larson
A. Noelle Larson
MMMichelle Claire Marks
Michelle Claire Marks
JGJuan Marcos Gonzalez
Juan Marcos Gonzalez
PNPeter O Newton
Peter O Newton
VDVincent J. Devlin
Vincent J. Devlin
TGthe Harms Study Group
the Harms Study Group
Background: Vertebral body tethering and other non-fusion techniques for the treatment of pediatric idiopathic scoliosis are increasing in popularity. There is limited physician consensus on this topic as the result of a paucity of published data regarding which patients most benefit from non-fusion strategies. Thus, much of the decision-making is left to patients and parents, who must select a treatment based on their goals and values and the information available from health-care providers, the internet, and social media. We sought to understand patient and family preferences regarding the attributes of fusion versus non-fusion surgery that drive these choices. Methods: Patients and families were recruited from 7 pediatric spine centers and were asked to complete a survey-based choice experiment that had been jointly developed with the U.S. Food and Drug Administration (FDA) to evaluate patient preferences. Choices between experimentally designed alternatives were analyzed to estimate the relative importance of outcomes and requirements associated with the choice options (attributes). The attributes included appearance, confidence in the planned correction, spinal motion, device failure, reoperation, and recovery period. The inclusion criteria were (1) an age of 10 to 21 years and (2) a diagnosis of adolescent idiopathic scoliosis in patients who were considering, or who had already undergone, treatment with fusion or non-fusion surgery. Preference weights were estimated from the expected changes in choice given changes in the attributes. Results: A total of 344 respondents (124 patients, 92 parents, and 128 parent/patient dyads) completed the survey. One hundred and seventy-three patients were enrolled prior to surgery, and 171 were enrolled after surgery. Appearance and motion were found to be the most important drivers of choice. For the entire cohort, fusion was preferred over non-fusion. For patients who were considering surgery, the most important attributes were preservation of spinal motion and appearance. Conclusions: Patients and families seeking treatment for idiopathic scoliosis value appearance and preservation of spinal motion and, to a lesser extent, reoperation rates when considering fusion versus non-fusion surgery.

1 January 2022 in Circulation: Heart Failure
Verified
Journal Article
Open access
PDF file
SRShelby D. Reed
Shelby D. Reed
JYJui-Chen Yang
Jui-Chen Yang
TRTimothy Rickert
Timothy Rickert
FJF. Reed Johnson
F. Reed Johnson
JGJuan Marcos Gonzalez
Juan Marcos Gonzalez
DBDean Bruhn-Ding
Dean Bruhn-Ding
Background: Regulatory and clinical decisions involving health technologies require judgements about relative importance of their expected benefits and risks. We sought to quantify heart-failure patients’ acceptance of therapeutic risks in exchange for improved effectiveness with implantable devices. Methods: Individuals with heart failure recruited from a national web panel or academic medical center completed a web-based discrete-choice experiment survey in which they were randomized to one of 40 blocks of 8 experimentally controlled choice questions comprised of 2 device scenarios and a no-device scenario. Device scenarios offered an additional year of physical functioning equivalent to New York Heart Association class III or a year with improved (ie, class II) symptoms, or both, with 30-day mortality risks ranging from 0% to 15%, in-hospital complication risks ranging from 0% to 40%, and a remote adjustment device feature. Logit-based regression models fit participants’ choices as a function of health outcomes, risks and remote adjustment. Results: Latent-class analysis of 613 participants (mean age, 65; 49% female) revealed that two-thirds were best represented by a pro-device, more risk-tolerant class, accepting up to 9% (95% CI, 7%–11%) absolute risk of device-associated mortality for a one-year gain in improved functioning (New York Heart Association class II). Approximately 20% were best represented by a less risk-tolerant class, accepting a maximum device-associated mortality risk of 3% (95% CI, 1%–4%) for the same benefit. The remaining class had strong antidevice preferences, thus maximum-acceptable risk was not calculated. Conclusions: Quantitative evidence on benefit-risk tradeoffs for implantable heart-failure device profiles may facilitate incorporating patients’ views during product development, regulatory decision-making, and clinical practice.

1 September 2021 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
QCQi N. Cui
Qi N. Cui
RHRon D. Hays
Ron D. Hays
MTMichelle E. Tarver
Michelle E. Tarver
GSGeorge L. Spaeth
George L. Spaeth
SPSylvia H. Paz
Sylvia H. Paz
KSKuldev Singh
Kuldev Singh