Tomoko Hyodo

Tomoko Hyodo

Auto-generated profile, based on publicly available information

Tomoko Hyodo

Department of Radiology, Faculty of Medicine, Kindai University, Osaka-Sayama, Japan

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2013 in Radiology
Verified
Journal Article
Closed access
THTomoko Hyodo
Tomoko Hyodo
TMTakamichi Murakami
Takamichi Murakami
YIYasuharu Imai
Yasuharu Imai
MOMasahiro Okada
Masahiro Okada
MHMasatoshi Hori
Masatoshi Hori
TMTeruhito Mochizuki
Teruhito Mochizuki
MR imaging findings, including hyperintensity on T2-weighted images and a higher growth rate may predict arterial hypervascularization, which may lead to early diagnosis and treatment of hepatocellular carcinoma. PurposeTo identify patient characteristics and magnetic resonance (MR) imaging findings associated with subsequent hypervascularization in hypovascular nodules that show hypointensity on hepatobiliary phase gadoxetic acid–enhanced MR images in patients with chronic liver diseases.Materials and MethodsInstitutional review board approval was obtained, and informed consent was waived. At multiple follow-up gadoxetic acid–enhanced MR imaging examinations of 68 patients, 160 hypovascular nodules were retrospectively reviewed. A Cox regression model for hypervascularization was developed to explore the association of baseline characteristics, including patient factors (Child-Pugh classification, etiology of liver disease, history of local therapy for hepatocellular carcinoma [HCC], and coexistence of hypervascular HCC) and MR imaging findings (fat content, signal intensity on T2-weighted images, and nodule size). In addition, the growth rate was calculated as the reciprocal of tumor volume doubling time to inve...

1 July 2012 in British Journal of Radiology
Verified
Journal Article
Closed access
THT Hyodo
T Hyodo
SKS Kumano
S Kumano
FKF Kushihata
F Kushihata
MOM Okada
M Okada
MHM Hirata
M Hirata
TMT Murakami
T Murakami
Recent developments in imaging technology have enabled CT and MR cholangiopancreatography (MRCP) to provide minimally invasive alternatives to endoscopic retrograde cholangiopancreatography for the pre- and post-operative assessment of biliary disease. This article describes anatomical variants of the biliary tree with surgical significance, followed by comparison of CT and MR cholangiographies. Drip infusion cholangiography with CT (DIC-CT) enables high-resolution three-dimensional anatomical representation of very small bile ducts (e.g. aberrant branches, the caudate branch and the cystic duct), which are potential causes of surgical complications. The disadvantages of DIC-CT include the possibility of adverse reactions to biliary contrast media and insufficient depiction of bile ducts caused by liver dysfunction or obstructive jaundice. Conventional MRCP is a standard, non-invasive method for evaluating the biliary tree. MRCP provides useful information, especially regarding the extrahepatic bile ducts...

1 April 2017 in Radiology
Verified
Journal Article
Closed access
THTomoko Hyodo
Tomoko Hyodo
NYNorihisa Yada
Norihisa Yada
MHMasatoshi Hori
Masatoshi Hori
OMOsamu Maenishi
Osamu Maenishi
PLPeter Lamb
Peter Lamb
TMTakamichi Murakami
Takamichi Murakami
The dual-energy CT–based multimaterial decomposition algorithm for liver fat quantification is accurate and reproducible and can be performed on both contrast- and real non–contrast-enhanced data sets, making it a clinically relevant technique. PurposeTo assess the clinical accuracy and reproducibility of liver fat quantification with the multimaterial decomposition (MMD) algorithm, comparing the performance of MMD with that of magnetic resonance (MR) spectroscopy by using liver biopsy as the reference standard.Materials and MethodsThis prospective study was approved by the institutional ethics committee, and patients provided written informed consent. Thirty-three patients suspected of having hepatic steatosis underwent non—contrast material–enhanced and triple-phase dynamic contrast-enhanced dual-energy computed tomography (CT) (80 and 140 kVp) and single-voxel proton MR spectroscopy within 30 days before liver biopsy. Percentage fat volume fraction (FVF) images were generated by using the MMD algorithm on dual-energy CT data to measure hepatic fat content. FVFs determined by using dual-energy CT and percentage fat fractions (FFs) determined by using MR spectroscopy were compared with histologic steatosis grade (0–3, as defined by the nonalcoh...

17 April 2012 in Journal of Gastroenterology
Verified
Journal Article
Closed access
PDF file
TITatsuo Inoue
Tatsuo Inoue
Masatoshi KudoMasatoshi Kudo
Masatoshi Kudo
MKMina Komuta
Mina Komuta
SHSosuke Hayaishi
Sosuke Hayaishi
TUTaisuke Ueda
Taisuke Ueda
TMTakamichi Murakami
Takamichi Murakami

26 June 2020 in Japanese Journal of Radiology
Verified
Journal Article
Open access
PDF file
TKTakenori Kozuka
Takenori Kozuka
YMYuko Matsukubo
Yuko Matsukubo
TKTomoya Kadoba
Tomoya Kadoba
TOTeruyoshi Oda
Teruyoshi Oda
ASAyako Suzuki
Ayako Suzuki
KIKazunari Ishii
Kazunari Ishii
Purpose To evaluate the performance of a deep learning-based computer-aided diagnosis (CAD) system at detecting pulmonary nodules on CT by comparing radiologists’ readings with and without CAD. Materials and methods A total of 120 chest CT images were randomly selected from patients with suspected lung cancer. The gold standard of nodules ≥ 3 mm was established by a panel of three expert radiologists. Two less experienced radiologists read the images without and afterward with CAD system. Their reading times were recorded. Results The radiologists’ sensitivity increased from 20.9% to 38.0% with the introduction of CAD. The positive predictive value (PPV) decreased from 70.5% to 61.8%, and the F1-score increased from 32.2% to 47.0%. The sensitivity significantly increased from 13.7% to 32.4% for small nodules (3–6 mm) and from 33.3% to 47.6% for medium nodules (6–10 mm). CAD alone showed a sensitivity of 70.3%, a PPV of 57.9%, and an F1-score of 63.5%. Reading time decreased by 11.3% with the use of CAD. Conclusion CAD improved the less experienced radiologists’ sensitivity in detecting pulmonary nodules of all sizes, especially including a significant improvement in the detection of clinically important-sized medium nodules (6–10 mm) as well as small nodules (3–6 mm) and reduced their reading time.

1 December 2011 in Oncology
Verified
Journal Article
Closed access
PDF file
TMTakamichi Murakami
Takamichi Murakami
YIYasuharu Imai
Yasuharu Imai
MOMasahiro Okada
Masahiro Okada
THTomoko Hyodo
Tomoko Hyodo
WLWon-Jae Lee
Won-Jae Lee
BCByung Ihn Choi
Byung Ihn Choi
Detection, characterization, staging, and treatment monitoring are major roles in imaging diagnosis in liver cancers. Contrast-enhanced ultrasonography (CEUS) using microbubble contrast agents has expanded the role of US in the detection and diagnosis of liver nodules in patients at high risk of hepatocellular carcinoma (HCC). CEUS provides an accurate differentiation between benign and malignant liver nodules, which is critical for adequate management of HCC and is also useful for guidance of percutaneous local therapy of HCC and postprocedure monitoring of the therapeutic response. The technology of multidetector-row computed tomography (MDCT) has increased spatial and temporal resolutions of computed tomography (CT). It has made possible a more precise evaluation of the hemodynamics of liver tumor, and the diagnostic accuracy of dynamic MDCT has improved. Perfusion CT can measure tissue perfusion parameters quantitatively and can assess segmental hepatic function. Dynamic MDCT with high spatial and temporal resolution enables us to reconstruct 3- and 4-dimensional imaging, which is very useful for pretreatment evaluation. Dual-energy CT makes possible the differentiation of materials and tissues in images obtained based on the differences in iodine and water densities. Monochromatic images, which can be reconstructed by dual-energy CT data, provide some improvement in contrast and show a higher contrast-to-noise ratio for hypervascular HCCs. Dynamic magnetic resonance imaging with fast imaging sequence of 3-dimensional Fourier transformation T1-weighted gradient echo and nonspecific contrast medium can show high detection sensitivity of hypervascular HCC. However, the hepatic tissue-specific contrast medium, gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid, has become an essential contrast medium for liver imaging because of its higher diagnostic ability. It may replace CT during hepatic arteriography and during arterioportography.