Eva Kieslichova

Eva Kieslichova

Auto-generated profile, based on publicly available information

Eva Kieslichova

Department of Anesthesiology, Resuscitation and Intensive Care, Institute for Clinical and Experimental Medicine, Prague, Czech Republic

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 February 2024 in Diabetes Care
Verified
Journal Article
Open access
PDF file
BHBarbora Voglová Hagerf
Barbora Voglová Hagerf
MPMarek Protuš
Marek Protuš
LNLenka Nemetova
Lenka Nemetova
MMMilos Mraz
Milos Mraz
EKEva Kieslichova
Eva Kieslichova
AJAntonin Jabor
Antonin Jabor
OBJECTIVE: Glycemia management in critical care is posing a challenge in frequent measuring and adequate insulin dose adjustment. In recent years, continuous glucose measurement has gained accuracy and reliability in outpatient and inpatient settings. The aim of this study was to assess the feasibility and accuracy of real-time continuous glucose monitoring (CGM) in ICU patients after major abdominal surgery. RESEARCH DESIGN AND METHODS: We included patients undergoing pancreatic surgery and solid organ transplantation (liver, pancreas, islets of Langerhans, kidney) requiring an ICU stay after surgery. We used a Dexcom G6 sensor, placed in the infraclavicular region, for real-time CGM. Arterial blood glucose measured by the amperometric principle (ABL 800; Radiometer, Copenhagen, Denmark) served as a reference value and for calibration. Blood glucose was also routinely monitored by a StatStrip bedside glucose meter. Sensor accuracy was assessed by mean absolute relative difference (MARD), bias, modified Bland-Altman plot, and surveillance error grid for paired samples of glucose values from CGM and acid-base analyzer (ABL). RESULTS: We analyzed data from 61 patients and obtained 1,546 paired glucose values from CGM and ABL. Active sensor use was 95.1%. MARD was 9.4%, relative bias was 1.4%, and 92.8% of values fell in zone A, 6.1% fell in zone B, and 1.2% fell in zone C of the surveillance error grid. Median time in range was 78%, with minimum (<1%) time spent in hypoglycemia. StatStrip glucose meter MARD compared with ABL was 5.8%. CONCLUSIONS: Our study shows clinically applicable accuracy and reliability of Dexcom G6 CGM in postoperative ICU patients and a feasible alternative sensor placement site.

1 March 2013 in Transplantation Proceedings
Verified
Journal Article
Closed access
EKE. Kieslichova
E. Kieslichova
MRM. Rocen
M. Rocen
DMD. Merta
D. Merta
MKM. Kudla
M. Kudla
Igor SplichalIgor Splichal
Igor Splichal
RGR. Gürlich
R. Gürlich

14 August 2019 in BMC Surgery
Verified
Journal Article
Open access
PDF file
EKEva Kieslichova
Eva Kieslichova
MPMarek Protuš
Marek Protuš
DNDana Nemcova
Dana Nemcova
EUEva Uchytilova
Eva Uchytilova
Bacteraemia of the donor is not considered to be contraindication of organ procurement. On the other hand, infection of solid organ transplant recipients remains to be a major cause of their morbidity and mortality. When using organs from bacteraemic donors, individual risks need to be assessed and the appropriate antibiotic treatment applied. In this case series we report several serious donor–derived infectious complications in four out of five recipients of different organs from one single donor in the early posttransplant period. Donor-transmitted multi-drug resistant strains of Escherichia coli and Klebsiella pneumonia was confirmed by both serologic and molecular testing. To prevent donor-derived infections, careful microbiological screening followed by targeted antibiotic treatment is essential. Although such complications can never by completely prevented, a high index for potential bacterial infection in organ donors and transplant recipients should be routinely employed.

1 September 2013 in Transplantation Proceedings
Verified
Journal Article
Closed access
JSJan Sperl
Jan Sperl
SFS. Frankova
S. Frankova
EKE. Kieslichova
E. Kieslichova
MOMartin Oliverius
Martin Oliverius
LJL. Janousek
L. Janousek
JSJ. Spicak
J. Spicak

6 January 2021 in Mediators of Inflammation
Verified
Journal Article
Open access
PDF file
JFJanka Franeková
Janka Franeková
MPMarek Protuš
Marek Protuš
EKEva Kieslichová
Eva Kieslichová
ABAleš Březina
Aleš Březina
JKJitka Komrsková
Jitka Komrsková
AJAntonín Jabor
Antonín Jabor
Sepsis biomarkers change continuously during the postoperative period. We aimed to demonstrate the influence of immunosuppressants after transplantation (Tx) on presepsin, procalcitonin, CRP, white blood cells, and IL‐6. A group of 140 patients after major surgery (86 non‐Tx, 54 Tx) without any signs of sepsis or infectious complications was followed for 7 days. The changes in biomarkers were analyzed with respect to the type of surgery, organ, and induction immunosuppressant used (antithymocyte globulin, corticosteroids, or basiliximab/rituximab). Concentrations (95th percentiles) of presepsin and procalcitonin were higher in the Tx group (presepsin: Tx < 2380 vs. non‐Tx < 1368 ng/L, p < 0.05; procalcitonin: <28.0 vs. 3.49 μg/L, p < 0.05). In contrast, CRP and IL‐6 were lower in the Tx group (CRP: Tx < 84.2 vs. non‐Tx < 229 mg/L, p < 0.05; IL‐6: <71.2 vs. 317 ng/L, p < 0.05). Decreases in CRP and IL‐6 were found for all immunosuppressants, and procalcitonin was increased after antithymocyte globulin and corticosteroids. Negligible changes were found for white blood cells. Different responses of presepsin, procalcitonin, CRP, and IL‐6 were therefore found in patients without any infectious complications after major surgery or transplantation. Immunosuppression decreased significantly IL‐6 and CRP in comparison to non‐Tx patients, while procalcitonin was increased after corticosteroids and antithymocyte globulin only. Cautious interpretation of sepsis biomarkers is needed in the early posttransplant period. This work was conducted as a noninterventional (nonregistered) study.

28 September 2022 in Surgical Endoscopy
Verified
Journal Article
Closed access
PDF file
DSDagmar Simkova
Dagmar Simkova
JMJan Mares
Jan Mares
ZVZuzana Vackova
Zuzana Vackova
THTomas Hucl
Tomas Hucl
PSPetr Stirand
Petr Stirand
JMJan Martinek
Jan Martinek