Peter Krüger

Peter Krüger

Auto-generated profile, based on publicly available information

Peter Krüger

Department of Physics and Astronomy, University of Sussex, Brighton BN1 9QH, United Kingdom

Research Focus & Metrics

Academic Career Length

41Years (1986-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2006 in Nature
Verified
Journal Article
Closed access
PDF file
ZHZoran Hadzibabic
Zoran Hadzibabic
PKPeter Krüger
Peter Krüger
MCMarc Cheneau
Marc Cheneau
BBBaptiste Battelier
Baptiste Battelier
JDJean Dalibard
Jean Dalibard

22 September 2005 in Nature Physics
Verified
Journal Article
Closed access
PDF file
TSThorsten Schumm
Thorsten Schumm
SHS. Hofferberth
S. Hofferberth
LAL. M. Andersson
L. M. Andersson
SWS. Wildermuth
S. Wildermuth
SGS. Groth
S. Groth
PKP. Krüger
P. Krüger

1 January 2002
Verified
Book Chapter
Closed access
RFRon Folman
Ron Folman
PKPeter Krüger
Peter Krüger
JSJörg Schmiedmayer
Jörg Schmiedmayer
JDJohannes Denschlag
Johannes Denschlag
CHCarsten Henkel
Carsten Henkel

1 April 2017 in NeuroImage
Verified
Journal Article
Open access
EBElena Boto
Elena Boto
SMSofie S. Meyer
Sofie S. Meyer
VSVishal Shah
Vishal Shah
OAOrang Alem
Orang Alem
SKSvenja Knappe
Svenja Knappe
MBMatthew J. Brookes
Matthew J. Brookes
Advances in the field of quantum sensing mean that magnetic field sensors, operating at room temperature, are now able to achieve sensitivity similar to that of cryogenically cooled devices (SQUIDs). This means that room temperature magnetoencephalography (MEG), with a greatly increased flexibility of sensor placement can now be considered. Further, these new sensors can be placed directly on the scalp surface giving, theoretically, a large increase in the magnitude of the measured signal. Here, we present recordings made using a single optically-pumped magnetometer (OPM) in combination with a 3D-printed head-cast designed to accurately locate and orient the sensor relative to brain anatomy. Since our OPM is configured as a magnetometer it is highly sensitive to environmental interference. However, we show that this problem can be ameliorated via the use of simultaneous reference sensor recordings. Using median nerve stimulation, we show that the OPM can detect both evoked (phase-locked) and induced (non-phase-locked oscillatory) changes when placed over sensory cortex, with signals ~4 times larger than equivalent SQUID measurements. Using source modelling, we show that our system allows localisation of the evoked response to somatosensory cortex. Further, source-space modelling shows that, with 13 sequential OPM measurements, source-space signal-to-noise ratio (SNR) is comparable to that from a 271-channel SQUID system. Our results highlight the opportunity presented by OPMs to generate uncooled, potentially low-cost, high SNR MEG systems.

15 May 2000 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
RFRon Folman
Ron Folman
PKPeter Krüger
Peter Krüger
DCDonatella Cassettari
Donatella Cassettari
BHBjörn Hessmo
Björn Hessmo
TMThomas Maier
Thomas Maier
JSJörg Schmiedmayer
Jörg Schmiedmayer
Atoms can be trapped and guided using nanofabricated wires on surfaces, achieving the scales required by quantum information proposals. These atom chips form the basis for robust and widespread applications of cold atoms ranging from atom optics to fundamental questions in mesoscopic physics, and possibly quantum information systems.

26 August 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
EBElena Boto
Elena Boto
RBRichard Bowtell
Richard Bowtell
PKPeter Krüger
Peter Krüger
TFT Mark Fromhold
T Mark Fromhold
PMPeter G Morris
Peter G Morris
MBMatthew J Brookes
Matthew J Brookes
Magnetoencephalography (MEG) is a sophisticated tool which yields rich information on the spatial, spectral and temporal signatures of human brain function. Despite unique potential, MEG is limited by a low signal-to-noise ratio (SNR) which is caused by both the inherently small magnetic fields generated by the brain, and the scalp-to-sensor distance. The latter is limited in current systems due to a requirement for pickup coils to be cryogenically cooled. Recent work suggests that optically-pumped magnetometers (OPMs) might be a viable alternative to superconducting detectors for MEG measurement. They have the advantage that sensors can be brought to within ~4 mm of the scalp, thus offering increased sensitivity. Here, using simulations, we quantify the advantages of hypothetical OPM systems in terms of sensitivity, reconstruction accuracy and spatial resolution. Our results show that a multi-channel whole-head OPM system offers (on average) a fivefold improvement in sensitivity for an adult brain, as well as clear improvements in reconstruction accuracy and spatial resolution. However, we also show that such improvements depend critically on accurate forward models; indeed, the reconstruction accuracy of our simulated OPM system only outperformed that of a simulated superconducting system in cases where forward field error was less than 5%. Overall, our results imply that the realisation of a viable whole-head multi-channel OPM system could generate a step change in the utility of MEG as a means to assess brain electrophysiological activity in health and disease. However in practice, this will require both improved hardware and modelling algorithms.