Laura Aguilera Saiz

Laura Aguilera Saiz

Auto-generated profile, based on publicly available information

Laura Aguilera Saiz

Department of Surgical Oncology, Netherlands Cancer Institute, Amsterdam, The Netherlands

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 January 2024 in Journal of Robotic Surgery
Verified
Journal Article
Open access
PDF file
LSL. Aguilera Saiz
L. Aguilera Saiz
HGHarald Groen
Harald Groen
WHW. J. Heerink
W. J. Heerink
TRT. J. M. Ruers
T. J. M. Ruers
Robot-assisted surgery is increasingly used in surgery for cancer. Reduced overview and loss of anatomical orientation are challenges that might be solved with image-guided surgical navigation using electromagnetic tracking (EMT). However, the robot’s presence may distort the electromagnetic field, affecting EMT accuracy. The aim of this study was to evaluate the robot’s influence on EMT accuracy. For this purpose, two different electromagnetic field generators were used inside a clinical surgical environment: a table top field generator (TTFG) and a planar field generator (PFG). The position and orientation of sensors within the electromagnetic field were measured using an accurate in-house developed 3D board. Baseline accuracy was measured without the robot, followed by stepwise introduction of potential distortion sources (robot and robotic instruments). The absolute accuracy was determined within the entire 3D board and in the clinical working volume. For the baseline setup, median errors in the entire tracking volume within the 3D board were 0.9 mm and 0.3° (TTFG), and 1.1 mm and 0.4° (PFG). Adding the robot and instruments did not affect the TTFG’s position accuracy (p = 0.60), while the PFG’s accuracies decreased to 1.5 mm and 0.7° (p < 0.001). For both field generators, when adding robot and instruments, accuracies inside the clinical working volume were higher compared to the entire tracking 3D board volume, 0.7 mm and 0.3° (TTFG), and 1.1 mm and 0.7° (PFG). Introduction of a surgical robot and robotic instruments shows limited distortion of the EMT field, allowing sufficient accuracy for surgical navigation in robotic procedures.

23 August 2024 in European Urology
Verified
Journal Article
Open access
LSLaura Aguilera Saiz
Laura Aguilera Saiz
WHWouter J. Heerink
Wouter J. Heerink
HGHarald C. Groen
Harald C. Groen
MHMarijn A.J. Hiep
Marijn A.J. Hiep
HPHenk G. van der Poel
Henk G. van der Poel
TRTheo J.M. Ruers
Theo J.M. Ruers
Image-guided surgical navigation (IGSN) can enhance surgical precision and safety. The expansion of minimally invasive surgery has increased the demand for integration of these navigation systems into robot-assisted surgery. Our objective was to evaluate the integration of electromagnetic tracking with IGSN in robot-assisted sentinel lymph node biopsy (SLNB). We conducted a prospective feasibility study to test the use of IGSN in SLNB. In total, 25 patients scheduled for SLNB at The Netherlands Cancer Institute were included (March 2022 to March 2023). SLNB using IGSN was performed using a standardised technique with a da Vinci robot (Intuitive Surgical, Sunnyvale, CA, USA) in four-arm configuration. Feasibility was determined as the percentage of sentinel nodes (SNs) successfully identified via IGSN. Successful SN resection was defined as SNs correctly localised via navigation and validated ex vivo with a gamma probe. Surgeon feedback on the robot-assisted IGSN workflow was evaluated using the System Usability Scale (SUS). In accordance with the protocol, the first five patients were used for workflow optimisation, and the subsequent 20 patients were included in the analysis. IGSN led to successful identification of 91% (50/55) of the SNs. There were no complications associated with navigation. The surgeon feedback (SUS) was 60.9, with lowest scores reported for the user interface and workflow integration. IGSN during robot-assisted surgery was feasible and safe. The technique allowed identification and removal of predefined small pelvic lymph nodes. We carried out a study on the feasibility of imaging-guided navigation in robot-assisted prostate surgery. Our results show that this technique is feasible, safe, and effective.

11 June 2025 in Clinical Surgical Oncology
Verified
Journal Article
Open access
LSLaura Aguilera Saiz
Laura Aguilera Saiz
HGHarald Groen
Harald Groen
WHWouter J. Heerink
Wouter J. Heerink
TRTheo J.M. Ruers
Theo J.M. Ruers

10 October 2025 in International Journal of Gynecological Cancer
Verified
Journal Article
Open access
LSLaura Aguilera Saiz
Laura Aguilera Saiz
MHMarijn Hiep
Marijn Hiep
HGHarald C. Groen
Harald C. Groen
WHWouter J. Heerink
Wouter J. Heerink
HZHenry J.M.A.A. Zijlmans
Henry J.M.A.A. Zijlmans
TRTheo J.M. Ruers
Theo J.M. Ruers
In many countries inguinal sentinel lymph node removal is conventional for staging unifocal, macroscopic vulvar cancer 68 being useful. Patients' mean age was 74 ± 13 years. Most tumors were International Federation of Gynecology and Obstetrics stage IB (11/20), with 1 patient with stage IA and 8 patients with stage III; histologically, 19 were squamous cell carcinoma and 1 basaloid carcinoma. For successfully localized sentinel lymph nodes, there was no statistically significant difference in median time (CI -9 to 3, p = .32) between conventional (16 min [interquartile range; 13-20, standard deviation: 9]) and navigation intervention (15 min [interquartile range; 13-25, standard deviation: 13]). In conventional interventions, in 3 of 20 cases (15%, CI 3.2 to 37.5) the sentinel lymph node was not found. The search continued with navigation and all sentinel lymph nodes were successfully removed. No intra-operative complications occurred. Navigation's usability was high scoring 79 of 100 in the System Usability Scale. Surgeons reported improved decisiveness and the need of navigation to locate sentinel lymph nodes when high body mass index (defined as ≥30 kg/m2), non-visible methylene blue or high background radioactivity. This study showed that navigated sentinel lymph node procedure is feasible, and surgeons favor its use in challenging sentinel lymph node procedures.

7 August 2026 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
PDF file
LSLaura Aguilera Saiz
Laura Aguilera Saiz
WHWouter J. Heerink
Wouter J. Heerink
HGHarald C. Groen
Harald C. Groen
MHMarijn A. J. Hiep
Marijn A. J. Hiep
LVLisanne L. P. G. Venix
Lisanne L. P. G. Venix
TRTheo J. M. Ruers
Theo J. M. Ruers
Purpose: Image-guided surgical navigation can enhance surgical precision and safety. The rise of robot-assisted surgeries has increased the need of incorporating navigation systems. Our goal is to evaluate the integration of three novel techniques on registration, instrument tracking and visualization with navigation using the robot-assisted sentinel lymph node biopsy (SLNB). Methods: A prospective feasibility study was performed at the Netherlands Cancer Institute (November 2023–July 2025). In total, 30 patients scheduled for SLNB participated. First, registration and localization accuracy were analyzed. Secondly, surgeons answered questionnaires to evaluate the ultrasound registration, instrument tracking and enhanced visualization. Virtual reality (VR) and augmented reality (AR) were compared in the last ten patients. Feasibility was determined with the sentinel nodes (SN) percentage that were successfully localized by navigation and validated ex vivo with the gamma probe. Results: Per-protocol, the first ten patients were used for workflow optimization; the subsequent 20 patients were included in the analysis. Ultrasound registration was fast (7 min), accurate (0.1 cm) and intuitive. Tracked instruments were well-integrated and helped to localize precisely the SN (0.3 cm). Surgeons preferred VR while opening the resection path to find the SN and AR in proximity for exact localization. Using navigation, successful identification was achieved in 90% (45/50) SN. No navigation-related complications occurred. Conclusions: Integrating ultrasound registration, instrument tracking and enhanced visualization during robot-assisted surgery has the potential to improve clinical use and localization of navigation in robot-assisted surgeries. These techniques allow to safely identify and remove pre-defined small pelvic lymph nodes in the pelvis.