Choong Wook Lee

Choong Wook Lee

Auto-generated profile, based on publicly available information

Choong Wook Lee

Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2010 in American Journal of Roentgenology
Verified
Journal Article
Closed access
ECEun Jin Chae
Eun Jin Chae
JSJoon Beom Seo
Joon Beom Seo
YJYu Mi Jang
Yu Mi Jang
BKBernhard Krauss
Bernhard Krauss
CLChoong Wook Lee
Choong Wook Lee
KSKoun-Sik Song
Koun-Sik Song
OBJECTIVE. The purpose of this study was to prospectively evaluate the usefulness of scoring perfusion defects on perfusion images at dual-energy CT for assessment of the severity of pulmonary embolism.SUBJECTS AND METHODS. Thirty patients (13 men, 17 women; mean age, 55 ± 15 [SD] years; range, 26–81 years) with pulmonary thromboembolism underwent dual-source CT at two voltages (140 and 80 kV). The weighted average image of two acquisitions was used for CT angiograms, and a color-coded iodine image was used for perfusion images. Two thoracic radiologists with 15 and 6 years of clinical experience independently assigned perfusion defect scores to perfusion images and both a CT angiographic (CTA) obstruction score and right ventricular–to–left ventricular (RV/LV) diameter ratio to CT angiograms. The CTA obstruction score was based on the Qanadli method. The perfusion defect score was defined as Σ (n · d) / 40 × 100, where n is the number of segments and d is the degree of perfusion from 0 to 2. Correlations...

1 June 2010 in Investigative Radiology
Verified
Journal Article
Closed access
ECEun Jin Chae
Eun Jin Chae
JSJoon Beom Seo
Joon Beom Seo
JLJeongjin Lee
Jeongjin Lee
Namkug KimNamkug Kim
Namkug Kim
HGHyun Woo Goo
Hyun Woo Goo
YCYou Sook Cho
You Sook Cho
To assess the feasibility of xenon ventilation computed tomography (CT) for evaluating ventilation abnormality in asthmatics. Twenty-two, stable asthmatics (M:F = 10:12; mean age, 57.6) were included. Single-phase, whole-thorax, dual-energy CT was performed using dual-source CT (Somatom Definition, Siemens) after subjects had inhaled 30% xenon for 90 seconds. Parameters include 512 x 512 matrix; 14 x 1.2 mm collimation; 40/140 eff. mAs at 140/80 kV; 0.45 pitch; and 0.33 seconds rotation time. On the color-coded xenon map, the extent of the ventilation defect was visually assessed using a 5-point scale in each lobe (0, absent defect; 1, 0%-25%; 2, 25%-50%; 3, 50%-75%; and 4, 75%-100%), which was defined as defect score. On the weighted average image, airway wall dimensions were measured at 4 segmental bronchi in both upper and lower lobes. Patients were classified into a defect group and a defect-free group based on the presence of defects shown on the xenon map. Pulmonary function test parameters and airway wall dimensions were compared in those 2 groups. Correlation analyses between the defect score, pulmonary function test, and airway wall dimensions were performed. Sixteen asthmatics showed peripheral ventilation defects on the xenon map (defect score, 6.6 +/- 4.2). The defect group had a significantly lower forced expiratory volume in 1 second (FEV1) and thicker airway wall than that of the defect-free group (P = 0.04 and 0.02, respectively). The defect score correlated negatively with a ratio of FEV1 and forced vital capacity (FEV1/FVC) (r = -0.44, P = 0.04) and corrected diffusing capacity (r = -0.76, P = 0.04) and correlated positively with total lung capacity, functional residual volume, and residual volume (r = 0.90, P = 0.005; r= 0.99, P < 0.001; r = 0.88, P = 0.008, respectively). The ventilation defects appeared on xenon ventilation CT in asthmatics with more severe airflow limitation and airway wall thickening. The extent of the ventilation defects showed correlations with parameters of pulmonary function test.

1 November 2010 in Journal of Thoracic Imaging
Verified
Journal Article
Closed access
ECEun Jin Chae
Eun Jin Chae
JSJae-Woo Song
Jae-Woo Song
BKBernhard Krauss
Bernhard Krauss
KSKoun-Sik Song
Koun-Sik Song
CLChoong Wook Lee
Choong Wook Lee
JSJoon Beom Seo
Joon Beom Seo
For the assessment of solitary pulmonary nodules (SPNs), a chest computed tomography (CT) is often performed as a combination of a nonenhanced and an enhanced scan. A nonenhanced scan is used for the detection of calcification in the SPN or lymph node, as the presence of calcification is one of the important determinants of benignity. An enhanced scan is informative in providing the degree and pattern of enhancement. In particular, the degree of enhancement of an SPN after iodine injection has been shown to be helpful in distinguishing malignant from benign nodules. Recently introduced dual-energy applications of dual-source CT simultaneously provide a virtual nonenhanced and an iodine-enhanced image from a single scan, after the administration of iodine contrast material. Therefore, a single enhanced dual-energy CT scan allows both measurement of the degree of enhancement and detection of calcifications. It may reduce radiation exposure to patients by avoiding baseline nonenhanced scans and may also reduce measurement error due to different regions of interest during the subtraction of a nonenhanced image from an enhanced image. This technique may have applications in contrast-enhanced dynamic CT and perfusion CT for the differentiation between benign and malignant lesions and the assessment of tumor angiogenesis. In this review article, we sought to address the usefulness of dual-energy CT for the assessment of SPN. In addition, we briefly review the physical principles of dual-energy CT and discuss potential future applications in patients with lung nodules.

1 August 2010 in European Radiology
Verified
Journal Article
Closed access
PDF file
CLChoong Wook Lee
Choong Wook Lee
JSJoon Beom Seo
Joon Beom Seo
JSJae-Woo Song
Jae-Woo Song
MKMi-Young Kim
Mi-Young Kim
HLHa Young Lee
Ha Young Lee
BKBernard Krauss
Bernard Krauss

1 August 2004 in Radiology
Verified
Journal Article
Closed access
JBJae Ho Byun
Jae Ho Byun
TKTae Kyoung Kim
Tae Kyoung Kim
CLChoong Wook Lee
Choong Wook Lee
JLJeong Kyong Lee
Jeong Kyong Lee
AKAh Young Kim
Ah Young Kim
MLMoon-Gyu Lee
Moon-Gyu Lee
To compare the prevalence of arterioportal (AP) shunting associated with (a) small (< or =3 cm) hemangiomas and (b) hepatocellular carcinomas (HCCs) (< or =3 cm) at two-phase helical computed tomography (CT). Two-phase helical liver CT was performed in 107 patients (61 men, 46 women; age range, 25-73 years; mean, 48.6 years) with 169 small hemangiomas and in 384 patients (292 men, 92 women; age range, 18-82 years; mean, 58.3 years) with 598 HCCs 3 cm or smaller. Diagnosis of HCC was verified with histologic findings (n = 30) or typical imaging and clinical findings (n = 568); that of all hemangiomas was verified with typical imaging and clinical findings. Three radiologists retrospectively reviewed all CT images in consensus. Contrast material-enhanced CT scans were obtained during the hepatic arterial and portal venous phases. AP shunt was considered to be present when wedge-shaped or irregularly shaped homogeneous enhancement peripheral to tumor appeared at hepatic arterial phase CT and isoattenuation or slight hyperattenuation in that area appeared at portal phase CT. The prevalence of AP shunting associated with hemangiomas and that associated with HCCs were compared with multivariate model testing. Speed of lesion enhancement (rapid enhancement, when extent of intratumoral enhancement at hepatic arterial phase CT was >50%; slow enhancement, when extent of intratumoral enhancement was < or =50%) and presence of AP shunt were correlated with chi2 or Fisher exact testing. AP shunts were more frequently found in hemangiomas (36 lesions [21.3%]) than in HCCs (25 lesions [4.2%]) (P <.001). Twenty-four (38%) of the 64 hemangiomas with rapid enhancement had AP shunts, whereas only 12 (11.4%) of the 105 hemangiomas with slow enhancement had AP shunts (P <.001). There was no significant difference between prevalence of AP shunt in the 573 HCCs with rapid enhancement (24 lesions, 4.2%) and that in the 25 HCCs with slow enhancement (one lesion, 4.0%). AP shunts were more frequently seen at two-phase helical CT in small hepatic hemangiomas than in HCCs and thus represent a suggestive but not specific finding of hemangioma. Small hemangiomas with AP shunts tend to show rapid rather than slow enhancement.

1 April 2013 in British Journal of Radiology
Verified
Journal Article
Closed access
YLY Lee
Y Lee
JSJ-W Song
J-W Song
ECE J Chae
E J Chae
HLH J Lee
H J Lee
CLC-W Lee
C-W Lee
TST S Shim
T S Shim
To describe CT findings of non-tuberculous mycobacteria (NTM) pulmonary infection in non-AIDS immunocompromised patients (ICPs) and to compare these findings with those in immunocompetent patients. From July 2000 to August 2007, 369 patients (mean age 58.3 years; 169 males and 200 females) with pulmonary NTM infection were retrospectively reviewed. Of these 369 patients, 24 ICPs (mean age 64.8 years; 15 males and 9 females) were identified. 16 patients had diabetes mellitus, and 6 patients had received long-term steroid therapy. One had received solid organ transplantation and one had received high-dose chemotherapy for haematological disease. 24 age- and sex-matched immunocompetent patients (mean age 64.6 years; 15 males and 9 females) were selected as the control group from the same registry. CT images were reviewed in consensus by three chest radiologists, who were blinded to immune status. Each lung lobe was evaluated in terms of extent of the lesion, bronchiectasis, parenchymal opacity and the presence of ancillary findings. results: A total of 287 lobes were evaluated in ICPs and the control group. The ICPs showed a higher prevalence of ill-defined nodules, with cavities and large opacity >2 cm with/without cavity (p=0.03, 0.04 and 0.02, respectively). Regardless of the immune status, the most common CT findings were bronchiectasis and ill-defined nodules without cavity. The most common CT findings of pulmonary NTM infection in ICPs were bronchiectasis and ill-defined nodules, similar to those in the control group. Ill-defined nodules with cavity and large opacity >2 cm with/without cavity were more frequently found in ICPs. In patients affected by NTM infection, large opacities and cavitation in pulmonary nodules are more frequent in ICPs than in immunocompetent patients.