Tomasz Moszura

Tomasz Moszura

Auto-generated profile, based on publicly available information

Tomasz Moszura

Department of Cardiology,Polish Mother's Memorial Hospital, Research Institute,Lodz,Poland

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2009 in Journal of Ultrasound in Medicine
Verified
Journal Article
Open access
PDF file
MSMaciej Słodki
Maciej Słodki
JRJack Rychik
Jack Rychik
TMTomasz Moszura
Tomasz Moszura
KJKatarzyna Janiak
Katarzyna Janiak
MRMaria Respondek-Liberska
Maria Respondek-Liberska
Objective. We investigated the utility of analyzing prenatal mediastinal measures of the great arteries in distinguishing true coarctation of the aorta (CoA) from false‐positive CoA. Methods. All fetuses in this study had suspicion of CoA based on the presence of right‐left heart disproportion. We defined 3 study groups: group 1, true fetal CoA; group 2, false‐positive fetal CoA with a narrow aortic arch; and group 3, false‐positive fetal CoA without a narrow aortic arch. Results. In group 1, the mean mediastinal pulmonary artery (PA) to ascending aorta (Ao) diameter ratio ± SD was 2.03 ± 0.48, and in group 2, the ratio was 1.60 ± 0.23. The difference was statistically significant (P = .0018, t test). In group 3, the mean PA:Ao ratio was 1.35 ± 0.14. The difference between groups 1 and 3 was statistically significant (P = .0002, t test). In our study group, for a PA:Ao ratio of 1.60, sensitivity was 83.0%; specificity, 85.0%; positive predictive value, 62.5%; and negative predictive value, 94.0%. Conclusions. In the third trimester, the main PA:Ao ratio as measured in the fetal mediastinum can be a helpful tool in distinguishing true CoA requiring neonatal cardiac surgery from false‐positive CoA and simple disproportion requiring medical attention but no surgery in the first month of postnatal life.

27 May 2017 in Pediatric Cardiology
Verified
Journal Article
Closed access
PDF file
SGSebastian Goreczny
Sebastian Goreczny
PDPawel Dryzek
Pawel Dryzek
GMGareth J. Morgan
Gareth J. Morgan
MLMaciej Lukaszewski
Maciej Lukaszewski
JMJadwiga A. Moll
Jadwiga A. Moll
TMTomasz Moszura
Tomasz Moszura

13 December 2016 in Netherlands Heart Journal
Verified
Journal Article
Open access
PDF file
SGS. Goreczny
S. Goreczny
TMT. Moszura
T. Moszura
PDP. Dryzek
P. Dryzek
MLM. Lukaszewski
M. Lukaszewski
AKA. Krawczuk
A. Krawczuk
GMG. J. Morgan
G. J. Morgan
Introduction Three-dimensional rotational angiography (3DRA) has been used in the guidance of various transcatheter therapies including percutaneous pulmonary valve implantation (PPVI). The most recently available 3D image fusion software (VesselNavigator, Philips) extends this technology to use pre-registered computed tomography or magnetic resonance imaging datasets, promising reductions in contrast and radiation exposure along with shorter procedural times. Methods In this retrospective review, patients were assigned to three groups according to the mode of imaging guidance: two-dimensional angiography (2DA), 3DRA and VesselNavigator (VN) assisted valve implantation. Patient characteristics and catheterisation data were reviewed with a focus on contrast and radiation exposure, fluoroscopy, and procedural times. Results Between July 2012 and June 2016, 21 patients underwent PPVI: 8 with 2D guidance, 6 patients with 3DRA and most recently 7 patients with VN assistance. Patents in the VN group received significantly less absolute and weight indexed contrast when compared with those with 2DA or 3DRA guided PPVI. Patients in the 2DA group received a significantly higher total dose area product radiation dose and air kerma in comparison with patients with 3DRA and VN guided intervention. Application of VN resulted in the shortest fluoroscopy time, although not statistically significant, and a significantly shorter study time when compared with 2DA. Conclusions Utilisation of pre-intervention image manipulation with VesselNavigator for 3D guidance of PPVI results in a reduction in contrast and radiation exposure and study time as compared with traditional 2D guidance, and contrast usage as compared with 3DRA.

1 May 2010 in Interactive CardioVascular and Thoracic Surgery
Verified
Journal Article
Open access
PDF file
TMTomasz Moszura
Tomasz Moszura
MZMaria Zubrzycka
Maria Zubrzycka
KMKrzysztof W. Michalak
Krzysztof W. Michalak
BRBożena Rewers
Bożena Rewers
PDPaweł Dryżek
Paweł Dryżek
PBPiotr Burczyński
Piotr Burczyński
Modified Blalock–Taussig (B–T) shunt occlusion results in a sudden reduction of pulmonary vascular perfusion, causing dramatic saturation drop and cy

11 September 2016 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Closed access
PDF file
KMKrzysztof W. Michalak
Krzysztof W. Michalak
JMJadwiga A. Moll
Jadwiga A. Moll
KSKatarzyna Sobczak-Budlewska
Katarzyna Sobczak-Budlewska
MMMaciej Moll
Maciej Moll
PDPaweł Dryżek
Paweł Dryżek
JMJacek J. Moll
Jacek J. Moll
OBJECTIVES: Reoperations and catheter interventions after the arterial switch operation (ASO) are relatively rare, but their frequency varies among different centres. They significantly impact the postoperative course of children with transposition of the great arteries (TGA). The aim of this study was to assess the frequency of reoperations and catheter interventions in patients with TGA after the ASO and to identify the potential risk factors. METHODS: For this retrospective case review study we included all consecutive 715 patients with TGA who underwent the ASO in the Department of Cardiac Surgery between the years 1991 and 2015. All of the surgical procedures were performed by one cardiac surgery team led by J.J.M., using the same surgical technique with his own specific modifications. RESULTS: The overall early mortality after the ASO was 7.4%; late mortality occurred in 15 cases (2.3%) and the mean clinical follow-up of our cohort was 10.5 years. Early reoperations (<30 days after surgery) were performed in 37 patients (5.1%). Reoperations were performed in 31 patients (4.7% of survivors), and their risk factors were previous early reoperation and left ventricle outflow tract obstruction, while isolated TGA reduced the risk of reoperations. Catheter interventions were performed in 25 patients (3.8% of survivors). In the majority of the cases, the indications for percutaneous procedures were pulmonary stenosis and recoarctation of the aorta. The statistically significant risk factors were aortic arch anomalies associated with TGA and neopulmonary artery anastomosis with a patch, while isolated TGA decreased the risk of reintervention. Freedom from cumulative reinterventions after the ASO was 90.4% at 5 years; 88.0% at 10 years; 86.5% at 15 years and 86.5% from 20 to 25 years. CONCLUSION: The frequency of reoperations and percutaneous interventions in patients with TGA after the ASO remains low. The majority of the procedures are performed because of pulmonary stenosis and recoarctation of aorta. Cardiac anomalies associated with TGA have a significant impact on the incidence of reoperation and reintervention.

1 January 2012 in The Annals of Thoracic Surgery
Verified
Journal Article
Closed access
JMJacek J. Moll
Jacek J. Moll
KMKrzysztof W. Michalak
Krzysztof W. Michalak
KMKatarzyna Młudzik
Katarzyna Młudzik
TMTomasz Moszura
Tomasz Moszura
MKMarek Kopala
Marek Kopala
JMJadwiga A. Moll
Jadwiga A. Moll