Laboratory of Water Management Research, Department of Water Structures, Faculty of Civil Engineering, Brno University of Technology, Veveří 331/95, 602 00, Brno, Czech Republic
Auto-generated profile, based on publicly available information
Jan Šulc
Laboratory of Water Management Research, Department of Water Structures, Faculty of Civil Engineering, Brno University of Technology, Veveří 331/95, 602 00, Brno, Czech Republic
This paper is concerned with the determination of the relationship for the calculation of the discharge coefficient at free overflow over a rectangular sharp-edged broad-crested weir without lateral contraction. The determination was made on the basis of new measurement in a range of the relative thickness of the weir from 0.12 to 0.30 and newly in a large range of relative height of the weir extremely from 0.24 to 6.8 which greatly expands the application possibilities of low weirs. In addition, the effects of friction and surface tension on the value of the discharge coefficient were evaluated as well as the effect of the relative thickness of the weir. The new equation for discharge coefficient, expressed using the relative height of the weir, was subjected to verification made by an independent laboratory which confirmed its accuracy.
1 September 2013 in Journal of Hydrology and Hydromechanics
The paper deals with selected procedures used to calculate the shape of compact nappe during free overfall from a smooth horizontal channel with rectangular cross section. Calculated and measured water surface and velocity conditions in the end section, the level of water surface upstream in front of the end section and the shape of the compact part of an overfall nappe are described for a particular compared case.