Functional near-infrared spectroscopy (fNIRS) is a technology that measures functional changes in the hemodynamics of the brain.1 In its simplest form, near-infrared sources and detectors are placed on the scalp, and changes in the optical properties of the tissue produced by hemodynamic activity are detected as changes in the detected light intensity. The technology is widely used in cognitive studies,2,3 for populations that cannot use fMRI, as well as for other applications, such as brain–computer interfaces4 or clinical diagnosis.5 The most common mode of fNIRS, in which light is emitted and detected continuously, is known as continuous wave fNIRS (CW fNIRS). Although this type of setup is very easy to implement, it has the disadvantage that it is not always easy to distinguish when changes in intensity are produced by hemodynamics of the brain or by other physiology, e.g., by hemodynamic changes in the scalp or motion artifacts.6,7 One of the reasons for this is that all photons reaching the detector are modulated by skin hemodynamics produced by respiration and the cardiac pulse. Furthermore, CW fNIRS detectors integrate photons from a large number of paths in the tissue, many of which did not reach the brain, reducing the contrast to brain ratio.
Continuous-wave functional near-infrared spectroscopy (fNIRS) is a noninvasive neuroimaging technique that measures cerebral hemoglobin concentration changes using an array of light sources and detectors placed on the surface of the head.1–5 The detected light reflects the hemodynamic changes not only in the cortex but also in the superficial tissues through which the light propagates, i.e., scalp, skull, and cerebrospinal fluid (CSF).6–9 Moreover, measurements are more sensitive to extracerebral tissues that are closer to the detectors and much less sensitive to the brain cortex, where the brain functional activity takes place.10 Thus accurately modeling the cerebral hemodynamic response function (HRF) and distinguishing it from the extracerebral signals is essential to robustly estimating brain activation.
Functional near-infrared spectroscopy (fNIRS) is a noninvasive technique capable of monitoring brain activity in the human cortex as revealed by changes in cerebral hemodynamics.1,2 While fNIRS is constrained to cortical brain areas, it has comparatively less stringent technical requirements than fMRI, opening the possibility for portable applications in the everyday world.3 In addition, due to its immunity to electromagnetic artifacts and relative resistance to motion artifacts, fNIRS can be used in patient populations that are otherwise restricted for fMRI, such as children or people with metal implants or pacemakers.4 Multiple applications have been proposed for wearable fNIRS systems, for example, in the fields of neuroergonomics,5 brain computer interfaces (BCIs),6 and neuromarketing.7 Portable fNIRS systems will also improve the capabilities for performing basic research on the mental processes related to locomotion and social interactions.8,9
Functional Near-Infrared Spectroscopy (fNIRS) holds transformative potential for research and clinical applications in neuroscience due to its non-invasive nature and adaptability to real-world settings. However, despite its promise, fNIRS signal quality is sensitive to individual differences in biophysical factors such as hair and skin characteristics, which can significantly impact the absorption and scattering of near-infrared light. If not properly addressed, these factors risk biasing fNIRS research by disproportionately affecting signal quality across diverse populations. Our results quantify the impact of various hair properties, skin pigmentation as well as head size, sex and age on signal quality, providing quantitative guidance for future hardware advances and methodological standards to help overcome these critical barriers to inclusivity in fNIRS studies. We provide actionable guidelines for fNIRS researchers, including a suggested metadata table and recommendations for cap and optode configurations, hair management techniques, and strategies to optimize data collection across varied participants. This research paves the way for the development of more inclusive fNIRS technologies, fostering broader applicability and improved interpretability of neuroimaging data in diverse populations.
The use of fNIRS has grown exponentially since its inception,1,2 expanding our understanding of brain activity in a variety of contexts, such as in psychiatry,3–7 naturalistic environments,8 developmental research,9–11 low-resource contexts and global health,11–17 and for hyperscanning studies.18–21 Benefits of functional near-infrared spectroscopy (fNIRS) over other neuroimaging modalities are well-defined for its comparative motion artifact resistance, temporal resolution, portability and wearability, operational requirements and ease of use, comfort, and general ecological validity.22
Previous studies suggest that producing and comprehending semantically related words relies on inhibitory control over competitive lexical selection which results in the recruitment of the left inferior frontal gyrus (IFG). Few studies, however, have examined the involvement of other regions of the frontal cortex, such as the dorsolateral prefrontal cortex (DLPFC), despite its role in cognitive control related to lexical processing. The primary objective of this study was to elucidate the role of the DLPFC in the production and comprehension of semantically and phonologically related words in blocked cyclic naming and picture–word matching paradigms. Twenty-one adults participated in neuroimaging with functional near-infrared spectroscopy to measure changes in oxygenated and deoxygenated hemoglobin concentrations across the bilateral frontal cortex during blocked cyclic picture naming and blocked cyclic picture–word-matching tasks. After preprocessing, oxygenated and deoxygenated hemoglobin concentrations were obtained for each task (production, comprehension), condition (semantic, phonological) and region (DLPFC, IFG). The results of pairwise t-tests adjusted for multiple comparisons showed significant increases in oxygenated hemoglobin concentration over baseline in the bilateral DLPFC during picture naming for phonologically related words. For picture–word matching, we found significant increases in oxygenated hemoglobin concentration over baseline in the right DLPFC for semantically related words and in the right IFG for phonologically related words. We discuss the results in light of the inhibitory attentional control over competitive lexical access theory in contrast to alternative potential explanations for the findings.