Kentaro Nakahara

Kentaro Nakahara

Auto-generated profile, based on publicly available information

Kentaro Nakahara

Biometrics Research Labs, NEC Corporation, Hinode 1131, Abiko 270-1198, Chiba, Japan

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2022 in IEEE Sensors Journal
Verified
Journal Article
Open access
KFKenichiro Fukushi
Kenichiro Fukushi
CHChenhui Huang
Chenhui Huang
ZWZhenwei Wang
Zhenwei Wang
HKHiroshi Kajitani
Hiroshi Kajitani
FNFumiyuki Nihey
Fumiyuki Nihey
KNKentaro Nakahara
Kentaro Nakahara
We propose two on-line algorithms for stride parameter estimation for an in-shoe motion-sensor system (IMS) system: one for on-line stride segmentation based on stable foot-flat detection using foot-sole angle and the other for a three-dimensional zero-velocity-update for accurate stride parameterization. We developed a small and lightweight IMS device, which consists of an inertial measurement unit, micro control unit, and peripheral electrical components, integrated with an insole so that it can be placed inside a shoe at the arch of the foot. Stride parameters, i.e., stride length, walking speed, foot height, circumduction, peak foot sole angle in the dorsiflexion and plantarflexion directions, and toe-in/out angle, that characterize a user’s foot motion are estimated. We recruited 30 healthy participants and evaluated the precision of our IMS system by comparing the stride parameters calculated with this system with those acquired from a motion-capture system. The results indicate the precision of the system in terms of the root mean square error for stride length of 0.069 m, walking speed of 0.094 m/s, foot height of 1.5 cm, circumduction of 1.0 cm, peak foot-sole angle in the dorsiflexion of 3.3 deg. and in the plantarflexion directions of 5.9 deg., and toe-in/out angle of 2.5 deg. Our IMS system has good precision regarding all parameters and high reliability and promises to contribute to personal health and wellness services and solutions by serving as a powerful and practical tool for objective gait assessment in real-world contexts.

4 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
CHChenhui Huang
Chenhui Huang
KFKenichiro Fukushi
Kenichiro Fukushi
ZWZhenwei Wang
Zhenwei Wang
FNFumiyuki Nihey
Fumiyuki Nihey
HKHirosi Kajitani
Hirosi Kajitani
KNKentaro Nakahara
Kentaro Nakahara
To expand the potential use of in-shoe motion sensors (IMSs) in daily healthcare or activity monitoring applications for healthy subjects, we propose a real-time temporal estimation method for gait parameters concerning bilateral lower limbs (GPBLLs) that uses a single IMS and is based on a gait event detection approach. To validate the established methods, data from 26 participants recorded by an IMS and a reference 3D motion analysis system were compared. The agreement between the proposed method and the reference system was evaluated by the intraclass correlation coefficient (ICC). The results showed that, by averaging over five continuous effective strides, all time parameters achieved precisions of no more than 30 ms and agreement at the “excellent” level, and the symmetry indexes of the stride time and stance phase time achieved precisions of 1.0% and 3.0%, respectively, and agreement at the “good” level. These results suggest our method is effective and shows promise for wide use in many daily healthcare or activity monitoring applications for healthy subjects.

8 June 2023 in Sensors
Verified
Journal Article
Open access
PDF file
CHChenhui Huang
Chenhui Huang
FNFumiyuki Nihey
Fumiyuki Nihey
KIKazuki Ihara
Kazuki Ihara
KFKenichiro Fukushi
Kenichiro Fukushi
HKHirosi Kajitani
Hirosi Kajitani
KNKentaro Nakahara
Kentaro Nakahara
Frailty poses a threat to the daily lives of healthy older adults, highlighting the urgent need for technologies that can monitor and prevent its progression. Our objective is to demonstrate a method for providing long-term daily frailty monitoring using an in-shoe motion sensor (IMS). We undertook two steps to achieve this goal. Firstly, we used our previously established SPM-LOSO-LASSO (SPM: statistical parametric mapping; LOSO: leave-one-subject-out; LASSO: least absolute shrinkage and selection operator) algorithm to construct a lightweight and interpretable hand grip strength (HGS) estimation model for an IMS. This algorithm automatically identified novel and significant gait predictors from foot motion data and selected optimal features to construct the model. We also tested the robustness and effectiveness of the model by recruiting other groups of subjects. Secondly, we designed an analog frailty risk score that combined the performance of the HGS and gait speed with the aid of the distribution of HGS and gait speed of the older Asian population. We then compared the effectiveness of our designed score with the clinical expert-rated score. We discovered new gait predictors for HGS estimation via IMSs and successfully constructed a model with an “excellent” intraclass correlation coefficient and high precision. Moreover, we tested the model on separately recruited subjects, which confirmed the robustness of our model for other older individuals. The designed frailty risk score also had a large effect size correlation with clinical expert-rated scores. In conclusion, IMS technology shows promise for long-term daily frailty monitoring, which can help prevent or manage frailty for older adults.

1 March 2023 in IEEE Sensors Journal
Verified
Journal Article
Open access
CHChenhui Huang
Chenhui Huang
FNFumiyuki Nihey
Fumiyuki Nihey
KFKenichiro Fukushi
Kenichiro Fukushi
HKHiroshi Kajitani
Hiroshi Kajitani
YNYoshitaka Nozaki
Yoshitaka Nozaki
KNKentaro Nakahara
Kentaro Nakahara
Identifying and monitoring overpronation and oversupination in the long term during activities of daily living is essential for people’s ambulatory health. Using an in-shoe motion sensor (IMS) with power-saving functions is a potential solution. In this study, we challenged the development of an estimation model of foot function using the foot center of pressure excursion index (CPEI) as an index via linear multivariate regression, which is sufficiently light for this type of IMS. Data collected from 65 and 17 participants were involved in model construction and validation, respectively. We validated ten scenarios simulating daily living activities, including walking on different surfaces, using different shoes, with or without carrying a bag, and indoors and outdoors. We applied statistic parametric mapping (SPM) to determine significant predictors and performed our original feature selection algorithm, leave-one-subject-out LASSO, to compress the volume of the predictors. We successfully discovered significant sex-specific predictors for foot function estimation from foot motion and constructed large effect-sized sex-specific foot function estimation models that achieved high-precision CPEI estimation. In the validation, the model successfully estimated a maximum of 99.0% and 100.0% males’ and females’ data under the same experimental conditions with the training data and 92.8–100.0% and 85.8–100.0% data in different scenarios. The constructed models are effective and possible to provide applications for long-term foot function monitoring by using an IMS.

24 December 2021 in IEEE Sensors Journal
Verified
Journal Article
Open access
CHChenhui Huang
Chenhui Huang
KFKenichiro Fukushi
Kenichiro Fukushi
ZWZhenwei Wang
Zhenwei Wang
HKHirosi Kajitani
Hirosi Kajitani
FNFumiyuki Nihey
Fumiyuki Nihey
KNKentaro Nakahara
Kentaro Nakahara
Our purpose was to demonstrate the possibility of providing foot-healthcare application by using an in-shoe motion sensor (IMS) through validating the feasibility of applying an IMS for measuring the first metatarsophalangeal angle (FMTPA), which is the most important parameter regarding the common foot problem hallux valgus. Methods: The IMS signals can represent foot motions when the mid-foot and hindfoot were modelled as a rigid body. FMTPAs can be estimated from the foot-motion signals measured using an IMS embedded beneath the foot arch near the calcaneus side using a machine-learning method. The foot-motion signals were collected from 50 participants with different FMTPAs. The true FMTPAs were assessed from digital photography. Correlation-based feature-selection processes (significance level p < 0.05) were used to search for the predictors from the foot-motion signals. Leave-one-subject-out cross-validation, root mean squared error, and intra-class coefficients were used for FMTPA-estimation model evaluation. Results: Eleven FMTPA-impacted gait-phase clusters, which were used to construct effective foot-motion predictors, were observed in all gait-cycle periods except terminal swing. The range of the foot motion in the sagittal and coronal planes significantly correlated with the FMTPA (p < 0.05). Linear regression could be the best method for constructing an FMTPA estimation model with a root mean squared error and intra-class correlation coefficient of 4.2 degrees and 0.789, respectively. Conclusion: The results indicate the reliability of our FMTPA estimation model constructed from foot-motion signals and the possibility to providing foot-healthcare applications by using an IMS.

22 November 2022 in Biomechanics
Verified
Journal Article
Open access
PDF file
HYHaruki Yaguchi
Haruki Yaguchi
YSYusuke Sekiguchi
Yusuke Sekiguchi
KHKeita Honda
Keita Honda
KFKenichiro Fukushi
Kenichiro Fukushi
CHChenhui Huang
Chenhui Huang
SIShin-Ichi Izumi
Shin-Ichi Izumi
Background: Stair climbing is a part of the basic activities of daily living. Previous biomechanical analyses of stairs have been conducted in the laboratory, resulting in only a few steps. Therefore, the biomechanical characteristics of long stair climbing in the real world remain unclear. The purpose of this study was to identify differences in kinematic and kinetic in the lower limb between the beginning and end phases of long stair climbing in an outdoor environment using a wearable motion analysis system. Eight subjects (four males and four females) were included in the data analysis (age: 23.6 ± 0.5 years). The long stair was 66 consecutive steps out of 202 stone steps. A wearable motion analysis system comprised six inertial measurement units and foot pressure sensors. The maximum ankle joint flexion angle in the end phase was significantly increased more than in the beginning phase (p < 0.001). On the other hand, the other kinematic, kinetic, and stair climbing speeds showed no significant difference between the phases. The findings indicated that fatigue during long stair climbing might increase ankle dorsiflexion to compensate for forwarding propulsion.