Alexander Jönsson

Alexander Jönsson

Auto-generated profile, based on publicly available information

Alexander Jönsson

Department of micro and Nanotechnology, Technical University of Denmark, DK2800 Kgs Lyngby

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2016 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
JLJosiane P. Lafleur
Josiane P. Lafleur
AJAlexander Jönsson
Alexander Jönsson
SSSilja Senkbeil
Silja Senkbeil
JKJörg Kutter
Jörg Kutter

4 April 2017 in Analytical Chemistry
Verified
Journal Article
Open access
AJAlexander Jönsson
Alexander Jönsson
RSRasmus R. Svejdal
Rasmus R. Svejdal
NBNanna Bøgelund
Nanna Bøgelund
TNTam T. T. N. Nguyen
Tam T. T. N. Nguyen
HFHenrik Flindt
Henrik Flindt
JLJosiane P. Lafleur
Josiane P. Lafleur
To improve the sample handling, and reduce cost and preparation time, of peptide mapping LC-MS workflows in protein analytical research, we here investigate the possibility of replacing conventional enzymatic digestion methods with a polymer microfluidic chip based enzyme reactor. Off-stoichiometric thiol-ene is utilized as both bulk material and as a monolithic stationary phase for immobilization of the proteolytic enzyme pepsin. The digestion efficiency of the, thiol-ene based, immobilized enzyme reactor (IMER) is compared to that of a conventional, agarose packed bed, pepsin IMER column commonly used in LC-MS based protein analyses. The chip IMER is found to rival the conventional column in terms of digestion efficiency at comparable residence time and, using a 3D-printed interface, be directly interfaceable with LC-MS.

4 June 2018 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
AJAlexander Jönsson
Alexander Jönsson
JLJosiane P. Lafleur
Josiane P. Lafleur
DSDrago Sticker
Drago Sticker
JKJörg Kutter
Jörg Kutter
Pre-concentration and clean-up are essential sample preparation steps in environmental, forensics and bio-analytical assays. Here, we present work towards a fully integrated, replica molded all thiol–ene lab-on-a-chip solution for sample enrichment and mass spectrometry. A microfluidic chip based column, for solid phase extraction (SPE), was fabricated using thiol–ene as both bulk material and an in situ polymerized monolith. C11-alkyl chains, in the form of undecanethiol, could be directly immobilized at the monolith surface, through the thiol–ene click reaction. Capacity of the produced SPE columns, for the test compound anthracene, was investigated by UV/Vis absorbance by connecting the chips to the detector of a commercial CE instrument with the help of a 3D-printed chip holder. The column capacity for anthracene was found to be ca. 14 μg m−2, which is consistent with the surface density of functional groups present at the monolith surface. The SPE column was further integrated with a unique on-chip electrospray ionization (ESI) emitter and hyphenated to an ion trap mass spectrometer. The emitter is directly replica molded in the process of chip fabrication, without any additional post-processing, and features a three-dimensional taper. The produced electrospray was investigated in the range of 250–370 m/z and found to be stable with a relative standard deviation of 8 ± 3%. Using the endogenous steroid progesterone, on-line extraction was also investigated on the SPE-ESI chip by direct infusion. Recoveries ranging from 40–50% indicated that further work is required to improve performance. However, the potential of an all-polymer, inexpensive device for sample clean-up featuring an integrated ESI emitter opens up an array of possibilities for applications in fields where single-use devices are mandatory, such as medical, biological, and pharmaceutical applications.

5 March 2025 in Materials Advances
Verified
Journal Article
Open access
PDF file
AJAlexander Jönsson
Alexander Jönsson
AIAntonia Iatrou
Antonia Iatrou
LWLouise Wildfang
Louise Wildfang
DNDana J. Neumann
Dana J. Neumann
HGHakan Gürbüz
Hakan Gürbüz
MDMartin Dufva
Martin Dufva
Water autoclaved resin 3D prints leach less material, which correlates with improved biocompatibility. Differential gene expression indicates the suppression of extracellular matrix proteins.

5 November 2024 in Biofabrication
Verified
Journal Article
Open access
SGSavvini Gkouma
Savvini Gkouma
NBNayanika Bhalla
Nayanika Bhalla
SFSolène Frapard
Solène Frapard
AJAlexander Jönsson
Alexander Jönsson
HGHakan Gürbüz
Hakan Gürbüz
MHMy Hedhammar
My Hedhammar
Physiologically relevant human skin models that include key skin cell types can be used for in vitro drug testing, skin pathology studies, or clinical applications such as skin grafts. However, there is still no golden standard for such a model. We investigated the potential of a recombinant functionalized spider silk protein, FN-silk, for the construction of a dermal, an epidermal, and a bilayered skin equivalent (BSE). Specifically, two formats of FN-silk (i.e. 3D network and nanomembrane) were evaluated. The 3D network was used as an elastic ECM-like support for the dermis, and the thin, permeable nanomembrane was used as a basement membrane to support the epidermal epithelium. Immunofluorescence microscopy and spatially resolved transcriptomics analysis demonstrated the secretion of key ECM components and the formation of microvascular-like structures. Furthermore, the epidermal layer exhibited clear stratification and the formation of a cornified layer, resulting in a tight physiologic epithelial barrier. Our findings indicate that the presented FN-silk-based skin models can be proposed as physiologically relevant standalone epidermal or dermal models, as well as a combined BSE.

23 May 2025 in bioRxiv
Verified
Preprint
Open access
PDF file
TWThomas B. Wareham-Mathiassen
Thomas B. Wareham-Mathiassen
JSJuan D. Sánchez-Heredia
Juan D. Sánchez-Heredia
KWKe-Chuan Wang
Ke-Chuan Wang
CHCajsa R. Haupt
Cajsa R. Haupt
MKMagnus Karlsson
Magnus Karlsson
PJPernille Rose Jensen
Pernille Rose Jensen
Dissolution dynamic nuclear polarization NMR Spectroscopy (dDNP-NMR) has become a transformative tool for metabolic studies by significantly enhancing signal sensitivity more than three orders of magnitude compared to traditional NMR. However, NMR detection probes are optimized for round narrow glass tubes typically 5 mm in diameter, which impose constraints on their utility for metabolic studies of adhernt cells. Here, we present a novel NMR probe head integrated with a custom microfluidic chip that facilitates real-time monitoring of hyperpolarized substrate conversion from adhernt cells. This system enables metabolic flux analysis in a controlled, in vitro environment, as demonstrated by tracking the conversion of [1- 13 C] pyruvate to [1- 13 C] lactate in HeLa cells over 48 hours. To the best of our knowledge, this is the first demonstration of cell metabolism from an adhering monolayer of mammalian cells in combination with hyperpolarized NMR. The custom microfluidic chip design is modular and adaptable allowing expansion to dual-chamber chips, demonstrating its potential in applications for more complex cellular environments, such as Organ-on-a-Chip systems.