Short-Term Load Forecasting (STLF) is the most appropriate type of forecasting for both electricity consumers and generators. In this paper, STLF in a Microgrid (MG) is performed via the hybrid applications of machine learning. The proposed model is a modified Support Vector Regression (SVR) and Long Short-Term Memory (LSTM) called SVR-LSTM. In order to forecast the load, the proposed method is applied to the data related to a rural MG in Africa. Factors influencing the MG load, such as various household types and commercial entities, are selected as input variables and load profiles as target variables. Identifying the behavioral patterns of input variables as well as modeling their behavior in short-term periods of time are the major capabilities of the hybrid SVR-LSTM model. To present the efficiency of the suggested method, the conventional SVR and LSTM models are also applied to the used data. The results of the load forecasts by each network are evaluated using various statistical performance metrics. The obtained results show that the SVR-LSTM model with the highest correlation coefficient, i.e., 0.9901, is able to provide better results than SVR and LSTM, which have the values of 0.9770 and 0.9809, respectively. Finally, the results are compared with the results of other studies in this field, which continued to emphasize the superiority of the SVR-LSTM model.
Accurate and fast fault detection in transmission lines is of high importance to maintain the reliability of power systems. Most of the existing methods suffer from false detection of high-impedance faults. In this paper, the transfer function (TF) method is introduced to evaluate the effect of impedance and location of faults by analyzing the voltage and current signals in the frequency domain. Interpretation of the results of the TF method is considered as a weakness of this method. In order to alleviate this problem, a convolutional neural network (CNN) and the hybrid model of deep reinforcement learning (DRL) are utilized to identify and locate single-phase to ground short circuit faults in transmission lines. Single-phase to ground short circuit faults with various fault impedances are applied on an IEEE standard transmission line system. Then, the TF traces are calculated and are collected as input datasets for the proposed models. The fault location results for each network are evaluated via various statistical performance metrics such as correlation coefficient (R), mean squared error (MSE), and root mean squared error (RMSE). The R-value of the CNN and DRL models in fault identification is presented as 96.12% and 98.04%, respectively. Finally, in the early detection of single-phase to ground short circuit fault location (high impedance), the results revealed the efficiency of the DRL model with R=96.61% compared to CNN with R=95.21%.
23 November 2022 in Artificial Intelligence Review