Jingdong Peng

Jingdong Peng

Auto-generated profile, based on publicly available information

Jingdong Peng

School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, PR China

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 September 2016 in RSC Advances
Verified
Journal Article
Closed access
PDF file
LBLingli Bu
Lingli Bu
JPJingdong Peng
Jingdong Peng
HPHuanjun Peng
Huanjun Peng
SLShaopu Liu
Shaopu Liu
HXHuan Xiao
Huan Xiao
YHYan He
Yan He
Chromium(VI) is proved to be highly carcinogenic and mutagenic, thus sensitive and rapid sensors for monitoring Cr(VI) are in urgent demand. In this work, a facile fluorescent assay for the sensitive and selective detection of Cr(VI) was proposed based on static quenching combined with inner filter effect (IFE) using phosphate functionalized carbon dots (PCDs) as nanoprobes. A good linear quenching was observed in the range of 1.0–400 μM with a detection limit of 0.24 μM (σ/S = 3) under the optimized conditions. The nanoprobe was employed for detecting Cr(VI) in real water samples including river water and tap water with satisfactory recovery. Moreover, with the addition of Cr(VI), the color changes of PCDs can be easily observed by the naked eye under a UV lamp. Based on this, Cr(VI) test papers were fabricated for spot quick detection of Cr(VI).

7 September 2019 in Microchimica Acta
Verified
Journal Article
Closed access
PDF file
LBLingli Bu
Lingli Bu
TLTao Luo
Tao Luo
HPHuanjun Peng
Huanjun Peng
LLLing Li
Ling Li
DLDengying Long
Dengying Long
JHJing Huang
Jing Huang

1 April 2019 in The Analyst
Verified
Journal Article
Closed access
PDF file
DLDengying Long
Dengying Long
JPJingdong Peng
Jingdong Peng
HPHuanjun Peng
Huanjun Peng
HXHong Xian
Hong Xian
SLShiyu Li
Shiyu Li
RNRanxi Ni
Ranxi Ni
A quadruple-channel fluorescent sensor array based on label-free carbon dots (CDs) was fabricated to detect and discriminate a series of tetracyclines (TCs), including chlortetracycline (CTC), oxytetracycline (OTC), tetracycline (TC) and doxycycline (DOX). Blue-emitting carbon dots (B-CDs) and green-emitting carbon dots (G-CDs) were prepared to serve as four sensing elements. When the TCs were directly mixed with CDs, the fluorescence quenching phenomenon appeared. Since different TCs exhibited different affinities for sensing elements, the sensor array displays a distinct fluorescence pattern of the fluorescence intensity variation (F0 − F)/F0 for each of these TCs, which is further analyzed by principal component analysis (PCA). The present fluorescent sensor array has the capacity to differentiate TCs at a low concentration of 1 μM. Meanwhile, quantitative detection with a lower limit (0.30 μM) for TCs could be achieved by applying a single element. Moreover, a high accuracy (100%) examination of unknown samples is acquired. Finally, the fluorescent sensor array performs well in distinguishing binary mixtures and could also recognize TCs in milk.

1 October 2021 in Talanta
Verified
Journal Article
Closed access
JCJun Chen
Jun Chen
HPHuanjun Peng
Huanjun Peng
ZZZilong Zhang
Zilong Zhang
ZZZhongying Zhang
Zhongying Zhang
RNRanxi Ni
Ranxi Ni
JPJingdong Peng
Jingdong Peng

13 December 2023 in Applied Surface Science
Verified
Journal Article
Closed access
ZZZilong Zhang
Zilong Zhang
PLPeng Luo
Peng Luo
LGLihua Gan
Lihua Gan
YZYanan Zhao
Yanan Zhao
XWXiang Wang
Xiang Wang
JPJingdong Peng
Jingdong Peng

1 November 2019 in Journal of Chromatography A
Verified
Journal Article
Closed access
XWXiang Wang
Xiang Wang
JPJingdong Peng
Jingdong Peng
HPHuanjun Peng
Huanjun Peng
JCJun Chen
Jun Chen
HXHong Xian
Hong Xian
ZZZhongying Zhang
Zhongying Zhang