Xiaohua Liu

Xiaohua Liu

Auto-generated profile, based on publicly available information

Xiaohua Liu

College of Mechatronics and Control Engineering, Shenzhen University, Shenzhen 518060, China

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 July 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
TZTianfeng Zhou
Tianfeng Zhou
Zhanchen ZhuZhanchen Zhu
Zhanchen Zhu
XLXiaohua Liu
Xiaohua Liu
Zhiqiang LiangZhiqiang Liang
Zhiqiang Liang
XWXibin Wang
Xibin Wang
Chalcogenide glass (ChG) is increasingly demanded in infrared optical systems owing to its excellent infrared optical properties. ChG infrared optics including ChG aspherical and freeform optics are mainly fabricated using the single point diamond turning (SPDT) technique, which is characterized by high cost and low efficiency. This paper presents an overview of the ChG infrared optics fabrication technique through precision glass molding (PGM). It introduces the thermo-mechanical properties of ChG and models the elastic-viscoplasticity constitutive of ChG. The forming accuracy and surface defects of the formed ChG are discussed, and the countermeasures to improve the optics quality are also reviewed. Moreover, the latest advancements in ChG precision molding are detailed, including the aspherical lens molding process, the ChG freeform optics molding process, and some new improvements in PGM.

30 June 2021 in Polymers
Verified
Journal Article
Open access
PDF file
CGCheng Guo
Cheng Guo
XLXiaohua Liu
Xiaohua Liu
GLGuang Liu
Guang Liu
In recent years, many investigations have been devoted to fused deposition modeling (FDM) of high-performance polymer-polyetheretherketone (PEEK) and carbon-fiber-reinforced PEEK (CF/PEEK) for biomedical and aerospace applications. However, the staircase effect naturally brought about by FDM restricts further applications of 3D-printed PEEK and its composites in high-temperature molds, medical implants, and precision components, which require better or customized surface qualities. Hence, this work aimed to reduce the staircase effect and improve the surface quality of 3D-printed PEEK and CF/PEEK parts by dry milling of the fluctuant exterior surface. The co-dependency between 3D printing parameters (raster angle and layer thickness) and milling parameters (depth of cut, spindle speed, and feed rate per tooth) were investigated through experiments. The difference in removal mechanisms for PEEK and CF/PEEK was revealed. It was confirmed that the smearing effect enhanced the surface quality based on the morphology analysis and the simulation model. Both the raster angle of +45°/−45° and the small layer thickness could improve the surface quality of these 3D-printed polymers after dry milling. A large depth of cut and a large feed rate per tooth were likely to deteriorate the finished polymer surface. The spindle speed could influence the morphologies without significant changes in roughness values. Finally, a demonstration was performed to verify that dry milling of 3D-printed amorphous PEEK and CF/PEEK parts could lead to a high surface quality for critical requirements.

3 November 2017 in Journal of Manufacturing Science and Engineering
Verified
Journal Article
Closed access
PDF file
XLXiaohua Liu
Xiaohua Liu
TZTianfeng Zhou
Tianfeng Zhou
LZLin Zhang
Lin Zhang
WZWenchen Zhou
Wenchen Zhou
JYJianfeng Yu
Jianfeng Yu
JLJames Ly Lee
James Ly Lee
Localized rapid heating process utilizing carbide-bonded graphene-coated silicon molds is a high-efficiency and energy-saving technique for high-volume fabrication of polymer optics. The graphene coating is used as a rapid heating element because of its high thermal conductivity and low electrical resistivity. However, the optical property of molded polymer and its dependence on process conditions such as heat transfer have not been thoroughly investigated. In this research, finite element method (FEM) simulation was utilized to interpret temperature changes of the graphene coating and heat transfer between graphene and polymethylmethacrylate (PMMA) in localized rapid heating. Experiments were then carried out under different voltages to validate the numerical model. In addition, refractive index variation of the PMMA lens resulting from nonuniform thermal history in molding was demonstrated by simulation modeling as well. Finally, wavefront variation of a PMMA lens molded by localized rapid heating was first studied using an FEM model and then verified by optical measurements with a Shack–Hartmann wavefront sensor (SHWFS). The wavefront variation in a PMMA lens molded by conventional method was also measured. Compared with conventional molding process, localized rapid heating is shown to be a possible alternative for better optical performance with a much shorter cycle time.

21 June 2019 in Journal of Manufacturing Science and Engineering
Verified
Journal Article
Closed access
PDF file
XLXiaohua Liu
Xiaohua Liu
LZLin Zhang
Lin Zhang
WZWenchen Zhou
Wenchen Zhou
TZTianfeng Zhou
Tianfeng Zhou
JYJianfeng Yu
Jianfeng Yu
AYAllen Y. Yi
Allen Y. Yi
Injection molding of plastic optical lenses prevails over many other techniques in both efficiency and cost; however, polymer shrinkage during cooling, high level of uneven residual stresses, and refractive index variations have limited its potential use for high precision lens fabrication. In this research, we adopted a newly developed strong graphene network to both plano and convex fused silica mold surfaces and proposed a novel injection molding with graphene-coated fused silica molds. This advanced injection molding process was implemented in the molding of polymer-based plano-concave lenses resulting in reduced polymer shrinkage. In addition, internal residual stresses and refractive index variations were also analyzed and discussed in detail. Meanwhile, as a comparison of conventional injection mold material, aluminum mold inserts with the same shape and size were also diamond machined and then employed to mold the same plano-concave lenses. Finally, a simulation model using moldex3d was utilized to interpret stress distributions of both graphene and aluminum molds and then validated by experiments. The comparison between graphene-coated mold and aluminum mold reveals that the novel injection molding with carbide-bonded graphene-coated fused silica mold inserts is capable of molding high-quality optical lenses with much less shrinkage and residual stresses with a more uniform refractive index distribution.

16 July 2021 in Polymers
Verified
Journal Article
Open access
PDF file
XLXiaohua Liu
Xiaohua Liu
CGCheng Guo
Cheng Guo
YLYandong Liu
Yandong Liu
FWFeng Wang
Feng Wang
YFYanfeng Feng
Yanfeng Feng
Surface rapid heating process is an efficient and green method for large-volume production of polymer optics by adopting 3D graphene network coated silicon molds with high thermal conductivity. Nevertheless, the heat transfer mechanism including the interface thermal resistance evolution between 3D graphene network coating and polymer has not been thoroughly revealed. In this study, the interface thermal resistance model was established by simplifying the contact situation between the coating and polymethylmethacrylate (PMMA), and then embedding into the finite element method (FEM) model to study the temperature variations of PMMA in surface rapid heating process. Heating experiments for graphene network were then carried out under different currents to provide the initial heat for heat transfer model. In addition, residual stress of the PMMA lens undergoing the non-uniform thermal history during molding was presented by the simulation model together. Finally, the optimal molding parameters including heating time and pressure will be determined according to calculation results of the interface thermal resistance model and microlens array molding experiment was conducted to illustrate that the interface thermal resistance model can predict the temperature of the polymer to achieve a better filling of microlens array with smooth surface and satisfactory optical performance.