Mario Enrique Alcocer Avila

Mario Enrique Alcocer Avila

Auto-generated profile, based on publicly available information

Mario Enrique Alcocer Avila

Université de Bordeaux Centre Lasers Intenses et Applications (UMR CNRS/CEA 5107) Talence France

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 May 2020 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
MAMario E. Alcocer-Ávila
Mario E. Alcocer-Ávila
AFAymeric Ferreira
Aymeric Ferreira
MQMichele A. Quinto
Michele A. Quinto
CMClément Morgat
Clément Morgat
Elif HindiéElif Hindié
Elif Hindié
CCChristophe Champion
Christophe Champion
Background: Targeted radionuclide therapy (TRT) is gaining importance. For TRT to be also used as adjuvant therapy or for treating minimal residual disease, there is a need to increase the radiation dose to small tumours. The aim of this in silico study was to compare the performances of 161Tb (a medium-energy β− emitter with additional Auger and conversion electron emissions) and 177Lu for irradiating single tumour cells and micrometastases, with various distributions of the radionuclide. Methods: We used the Monte Carlo track-structure (MCTS) code CELLDOSE to compute the radiation doses delivered by 161Tb and 177Lu to single cells (14 μm cell diameter with 10 μm nucleus diameter) and to a tumour cluster consisting of a central cell surrounded by two layers of cells (18 neighbours). We focused the analysis on the absorbed dose to the nucleus of the single tumoral cell and to the nuclei of the cells in the cluster. For both radionuclides, the simulations were run assuming that 1 MeV was released per μm3 (1436 MeV/cell). We considered various distributions of the radionuclides: either at the cell surface, intracytoplasmic or intranuclear. Results: For the single cell, the dose to the nucleus was substantially higher with 161Tb compared to 177Lu, regardless of the radionuclide distribution: 5.0 Gy vs. 1.9 Gy in the case of cell surface distribution; 8.3 Gy vs. 3.0 Gy for intracytoplasmic distribution; and 38.6 Gy vs. 10.7 Gy for intranuclear location. With the addition of the neighbouring cells, the radiation doses increased, but remained consistently higher for 161Tb compared to 177Lu. For example, the dose to the nucleus of the central cell of the cluster was 15.1 Gy for 161Tb and 7.2 Gy for 177Lu in the case of cell surface distribution of the radionuclide, 17.9 Gy for 161Tb and 8.3 Gy for 177Lu for intracytoplasmic distribution and 47.8 Gy for 161Tb and 15.7 Gy for 177Lu in the case of intranuclear location. Conclusion: 161Tb should be a better candidate than 177Lu for irradiating single tumour cells and micrometastases, regardless of the radionuclide distribution.

1 October 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MAMario E. Alcocer-Ávila
Mario E. Alcocer-Ávila
Michele Arcangelo QuintoMichele Arcangelo Quinto
Michele Arcangelo Quinto
Juan MontiJuan Monti
Juan Monti
RRRoberto D. Rivarola
Roberto D. Rivarola
CCChristophe Champion
Christophe Champion
Whether it is in radiobiology to identify DNA lesions or in medicine to adapt the radiotherapeutic protocols, a detailed understanding of the radiation-induced interactions in living matter is required. Monte Carlo track-structure codes have been successfully developed to describe these interactions and predict the radiation-induced energy deposits at the nanoscale level in the medium of interest. In this work, the quantum-mechanically based Monte Carlo track-structure code TILDA-V has been used to compute the slowing-down of protons in water and DNA. Stopping power and range are then reported and compared with existing data. Then, a first application of TILDA-V to cellular irradiations is also reported in order to highlight the absolute necessity of taking into account a realistic description of the cellular environment in microdosimetry.

8 March 2022 in International Journal of Radiation Biology
Verified
Journal Article
Closed access
MÁMario Enrique Alcocer Ávila
Mario Enrique Alcocer Ávila
Elif HindiéElif Hindié
Elif Hindié
CCChristophe Champion
Christophe Champion
Auger emitters exhibit interesting features due to their emission of a cascade of short-range Auger electrons. Maximum DNA breakage efficacy is achieved when decays occur near DNA. Studies of doubl...

13 March 2024 in Medical Physics
Verified
Journal Article
Closed access
MAMario Enrique Alcocer‐Ávila
Mario Enrique Alcocer‐Ávila
ALAlexandre Larouze
Alexandre Larouze
JGJean‐Emmanuel Groetz
Jean‐Emmanuel Groetz
EHElif Hindié
Elif Hindié
CCChristophe Champion
Christophe Champion

29 September 2019 in Springer Proceedings in Physics
Verified
Book Chapter
Closed access
PDF file
MAMario E. Alcocer-Ávila
Mario E. Alcocer-Ávila
MQMichele A. Quinto
Michele A. Quinto
Juan MontiJuan Monti
Juan Monti
RRRoberto D. Rivarola
Roberto D. Rivarola
CCChristophe Champion
Christophe Champion

23 June 2019 in X-Ray Spectrometry
Verified
Journal Article
Closed access
PDF file
Michele Arcangelo QuintoMichele Arcangelo Quinto
Michele Arcangelo Quinto
Juan MontiJuan Monti
Juan Monti
MAMario Enrique Alcocer Avila
Mario Enrique Alcocer Avila
PWPhilippe F. Weck
Philippe F. Weck
Omar Ariel FojónOmar Ariel Fojón
Omar Ariel Fojón
CCChristophe Champion
Christophe Champion