Dinesh Nathwani

Dinesh Nathwani

Auto-generated profile, based on publicly available information

Dinesh Nathwani

Imperial Healthcare NHS Trust London United Kingdom

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 July 2021 in The International Journal of Medical Robotics and Computer Assisted Surgery
Verified
Journal Article
Closed access
PDF file
HKHasaan Khan
Hasaan Khan
KDKieran Dhillon
Kieran Dhillon
PMPiyush Mahapatra
Piyush Mahapatra
RPRavi Popat
Ravi Popat
OZOmar Zakieh
Omar Zakieh
DNDinesh Nathwani
Dinesh Nathwani

11 June 2022 in The Surgeon
Verified
Journal Article
Open access
RDRory Dyke
Rory Dyke
ESEdward St-John
Edward St-John
HSHemina Shah
Hemina Shah
JWJoseph Walker
Joseph Walker
DLDafydd Loughran
Dafydd Loughran
DNDinesh Nathwani
Dinesh Nathwani
The importance of shared decision making (SDM) for informed consent has been emphasised in the updated regulatory guidelines. Errors of completion, legibility and omission have been associated with paper-based consent forms. We introduced a digital consent process and compared it against a paper-based process for quality and patient reported involvement in shared decision making. 223 patients were included in this multi-site, single centre study. Patient consent documentation was by either a paper consent form or the Concentric digital consent platform. Consent forms were assessed for errors of legibility, completion and accuracy of content. Core risks for 20 orthopaedic operations were pre-defined by a Delphi round of experts and forms analysed for omission of these risks. SDM was determined via the 'collaboRATE Top Score', a validated measure for gold-standard SDM. 72% (n = 78/109) of paper consent forms contained ≥1 error compared to 0% (n = 0/114) of digital forms (P < 0.0001). Core risks were unintentionally omitted in 63% (n = 68/109) of paper-forms compared to less than 2% (n = 2/114) of digital consent forms (P < 0.0001). 72% (n = 82/114) of patients giving consent digitally reported gold-standard SDM compared to 28% (n = 31/109) with paper consent (P < 0.001). Implementation of a digital consent process has been shown to reduce both error rate and the omission of core risks on consent forms whilst increasing the quality of SDM. This novel finding suggests that using digital consent can improve both the quality of informed consent and the patient experience of SDM.


28 November 2019 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Open access
PDF file
AWAnatole Vilhelm Wiik
Anatole Vilhelm Wiik
DNDinesh Nathwani
Dinesh Nathwani
AAAhsan Akhtar
Ahsan Akhtar
BABilal Al-Obaidi
Bilal Al-Obaidi
RSRobin Strachan
Robin Strachan
JCJustin Cobb
Justin Cobb
Purpose: To determine the preferred knee in patients with both one total and one unicompartmental knee arthroplasty. Method: Patients simply with a unicompartmental (UKA) and total knee arthroplasty (TKA) on contralateral sides were retrospectively screened from three senior knee surgeon’s logs over a 15 year period. Patients safe and free from other diseases to affect gait were approached. A total of 16 patients (mean age 70 ± 8) agreed to ground reaction force testing on an instrumented treadmill at a fair pace and incline. A gender-ratio identical group of 16 healthy control subjects (mean age 67 ± 10) and 16 patients with ipsilateral medial knee OA (mean age 66 ± 7) were analysed to compare. Results: Radiographically the mode preoperative Kellgren–Lawrence knee grade for each side was 3. Postoperatively, the TKA side had a mean coronal femoral component alignment of 7° and a mean tibial coronal alignment of 89° with a mean posterior slope of 5° in the sagittal plane. The UKA side had a mean coronal femoral component alignment of 7° and a mean tibial coronal alignment of 86° with a mean posterior slope of 4° in the sagittal plane. In 7 patients, the TKA was the first procedure, while 6 for the UKA and 3 done simultaneously. Gait analysis demonstrated in both walking conditions the UKA limb was the preferred side through all phases of loading (p < 0.05) and nearer to normal than the TKA limb when compared to healthy controls and patients with knee OA. The greatest difference was observed between the transition of weight acceptance and midstance (p = 0.008), when 22% more load was taken by the UKA side. Conclusion: By using a dynamic metric of an everyday activity, a distinct gait difference between differing arthroplasty types were established. A more natural loading pattern can be achieved with unicompartmentals as compared to total knees. Level of evidence: Retrospective comparative study, Level III.

1 February 2014 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
CDClaudio Diaz-Ledezma
Claudio Diaz-Ledezma
JPJavad Parvizi
Javad Parvizi
YZYinxin Zhou
Yinxin Zhou
VAValentin Antoci
Valentin Antoci
PDPaul Ducheyne
Paul Ducheyne
ISIrving Shapiro
Irving Shapiro

10 September 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
RPRavi Popat
Ravi Popat
KDKieran Dhillon
Kieran Dhillon
PMPiyush Mahapatra
Piyush Mahapatra
HKHasaan Khan
Hasaan Khan
DNDinesh Nathwani
Dinesh Nathwani
Background: Preservation of joint line height is an important factor in post-operative function after Total Knee Arthroplasty (TKA). This is the first study investigating the reliability of the novel Imperial Joint Line Congruency Measurement (IJLCM) technique for the assessment of joint line height using plain radiographs.Methods: The reliability of two techniques used to measure joint line height on pre-operative and post-operative plain radiographs is presented. 120 patients that underwent TKA from 6 different international centres were included. Measurements were performed using each technique by two senior orthopaedic surgeons at two different timepoints (test-retest). Two undergraduate medical students performed joint line measurements using the most reproducible of the two techniques on 40 pre-operative and post-operative images to establish the reliability of the measurement technique.Results: The IJLCM demonstrated an average absolute difference of 1.83mm (CI 1.56–2.10mm) and excellent inter and intra-rater reliability between senior orthopaedic surgeons (>0.92 (CI 0.88–0.94) when measuring joint line height on plain radiographs. Overall Crohnbach’s alpha over 0.92 confirmed internal consistency. Measurements performed using the control technique as previously described by Figgie et al. had an average absolute difference of 5.75mm (5.17–6.32mm). Comparison of measurements by senior orthopaedic surgeons and medical students using the IJLCM technique with ANOVA and student’s t-test demonstrated acceptable agreement and inter-rater reliability of >0.92 (0.87–0.95).Conclusion: This study shows excellent accuracy, precision, and reliability of the novel IJLCM technique. Furthermore, excellent agreement between senior orthopaedic surgeons and medical students when using the IJLCM could be shown. The IJLCM technique is reliable for joint line assessment.