Manuela Ernst

Manuela Ernst

Auto-generated profile, based on publicly available information

Manuela Ernst

AO Research Institute Davos, Davos, Switzerland

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2022 in Medicina
Verified
Journal Article
Open access
PDF file
MWMarkus Windolf
Markus Windolf
VVViktor Varjas
Viktor Varjas
DGDominic Gehweiler
Dominic Gehweiler
RSRonald Schwyn
Ronald Schwyn
DADaniel Arens
Daniel Arens
MEManuela Ernst
Manuela Ernst
Background and Objectives: Fracture healing is currently assessed through qualitative evaluation of radiographic images, which is highly subjective in nature. Radiographs can only provide snapshots in time, which are limited due to logistics and radiation exposure. We recently proposed assessing the bone healing status through continuous monitoring of the implant load, utilizing an implanted sensor system, the Fracture Monitor. The device telemetrically transmits statistically derived implant parameters via the patient’s mobile phone to assist physicians in diagnostics and treatment decision-making. This preclinical study aims to systematically investigate the device safety and performance in an animal setting. Materials and Methods: Mid-shaft tibial osteotomies of different sizes (0.6–30 mm) were created in eleven Swiss mountain sheep. The bones were stabilized with either a conventional Titanium or stainless-steel locking plate equipped with a Fracture Monitor. Data were continuously collected over the device’s lifetime. Conventional radiographs and clinical CT scans were taken longitudinally over the study period. The radiographs were systematically scored and CTs were evaluated for normalized bone volume in the defect. The animals were euthanized after 9 months. The sensor output was correlated with the radiologic parameters. Tissue samples from the device location were histologically examined. Results: The sensors functioned autonomously for 6.5–8.4 months until energy depletion. No macroscopic or microscopic adverse effects from device implantation were observed. The relative implant loads at 4 and 8 weeks post-operation correlated significantly with the radiographic scores and with the normalized bone volume metric. Conclusions: Continuous implant load monitoring appears as a relevant approach to support and objectify fracture healing assessments and carries a strong potential to enable patient-tailored rehabilitation in the future.

1 June 2021 in Injury
Verified
Journal Article
Open access
MEManuela Ernst
Manuela Ernst
RRRobert Geoff Richards
Robert Geoff Richards
MWMarkus Windolf
Markus Windolf
The assessment of fracture healing is still marked by a subjective and diffuse outcome due to the lack of clinically available quantitative measures. Without reliable information on the progression of healing and uniform criteria for union and non-union, therapeutic decision making, e.g. regarding the allowed weight bearing, hinges on the experience and the subjective evaluation of physicians. Already decades ago, fracture stiffness has been identified as a valid outcome measure for the maturity of the repair tissue. Despite early promising results, so far no method has made its way into practice beyond clinical studies. However, with current technological advancements and a general trend towards digital health care, measuring fracture healing seems to regain momentum. New generations of instrumented implants with sensoring capabilities, often termed as "smart implants", are under development. They target X-ray free and timely provision of reliable feedback upon the mechanical competence of the repair tissue and the healing environment to support therapeutic decision making and individualized after-care. With the gained experience from these devices, the next generations of smart implants may become increasingly sophisticated by internally analyzing the measured data and suggesting adequate therapeutic actions on their own.

1 February 2021 in Journal of Biomechanics
Verified
Journal Article
Closed access
MEManuela Ernst
Manuela Ernst
HBHeiko Baumgartner
Heiko Baumgartner
SDStefan Döbele
Stefan Döbele
DHDankward Höntzsch
Dankward Höntzsch
TPTim Pohlemann
Tim Pohlemann
MWMarkus Windolf
Markus Windolf

1 January 2021 in Injury
Verified
Journal Article
Closed access
MWMarkus Windolf
Markus Windolf
MEManuela Ernst
Manuela Ernst
RSRonald Schwyn
Ronald Schwyn
DADaniel Arens
Daniel Arens
SZStephan Zeiter
Stephan Zeiter

6 July 2022 in Medicina
Verified
Journal Article
Open access
PDF file
MWMarkus Windolf
Markus Windolf
MHMaximilian Heumann
Maximilian Heumann
VVViktor Varjas
Viktor Varjas
CCCaroline Constant
Caroline Constant
MEManuela Ernst
Manuela Ernst
LBLorin M. Benneker
Lorin M. Benneker
Background and Objectives: Spinal fusion is an effective and widely accepted intervention. However, complications such as non-unions and hardware failures are frequently observed. Radiologic imaging and physical examination are still the gold standards in the assessment of spinal fusion, despite multiple limitations including radiation exposure and subjective image interpretation. Furthermore, current diagnostic methods only allow fusion assessment at certain time points and require the patient’s presence at the hospital or medical practice. A recently introduced implantable sensor system for continuous and wireless implant load monitoring in trauma applications carries the potential to overcome these drawbacks, but transferability of the principle to the spine has not been demonstrated yet. Materials and Methods: The existing trauma sensor was modified for attachment to a standard pedicle-screw-rod system. Two lumbar segments (L2 to L4) of one Swiss white alpine sheep were asymmetrically instrumented. After facetectomy, three sensors were attached to the rods between each screw pair and activated for measurement. The sheep was euthanized 16 weeks postoperatively. After radiological assessment the spine was explanted and loaded in flexion-extension to determine the range of motion of the spinal segments. Sensor data were compared with mechanical test results and radiologic findings. Results: The sensors measured physiological rod loading autonomously over the observation period and delivered the data daily to bonded smartphones. At euthanasia the relative rod load dropped to 67% of the respective maximum value for the L23 segment and to 30% for the L34 segment. In agreement, the total range of motion of both operated segments was lower compared to an intact reference segment (L23: 0.57°; L34: 0.49°; intact L45: 4.17°). Radiologic assessment revealed fusion mass in the facet joint gaps and bilateral bridging bone around the joints at both operated segments. Conclusions: Observations of this single-case study confirm the basic ability of continuous rod load measurement to resolve the spinal fusion process as indicated by a declining rod load with progressing bone fusion. A strong clinical potential of such technology is eminent, but further data must be collected for final proof of principle.

10 August 2021 in Biomedicines
Verified
Journal Article
Open access
PDF file
JBJan Barcik
Jan Barcik
MEManuela Ernst
Manuela Ernst
MBMarc Balligand
Marc Balligand
CDConstantin Edmond Dlaska
Constantin Edmond Dlaska
Ludmil DrenchevLudmil Drenchev
Ludmil Drenchev
MWMarkus Windolf
Markus Windolf
It is well known that mechanical stimulation promotes indirect fracture healing by triggering callus formation. We investigated the short-term response of healing tissue to mechanical stimulation to compare the changes in tissue stiffness during stimulation and resting phases in a preclinical case-series. Four sheep underwent a tibial osteotomy and were instrumented with a custom-made active fixator which applied a mechanical stimulation protocol of 1000 cycles/day, equally distributed over 12 h, followed by 12 h of rest. During each cycle, a surrogate metric for tissue stiffness was measured, enabling a continuous real-time monitoring of the healing progression. A daily stiffness increase during stimulation and an increase during resting were evaluated for each animal. One animal had to be excluded from the evaluation due to technical reasons. For all included animals, the stiffness began to increase within the second week post-op. A characteristic pattern was observed during daily measurements: the stiffness dropped considerably within the first stimulation cycles followed by a steady rise throughout the rest of the stimulation phase. However, for all included animals, the average daily stiffness increase within the first three weeks post operation was larger during resting than during stimulation (Sheep I: 16.9% vs. −5.7%; Sheep II: 14.7% vs. −1.8%; Sheep III: 8.9% vs. 1.6%). A continuous measurement of tissue stiffness together with a controlled fracture stimulation enabled the investigation of the short-term effects of specific stimulatory parameters, such as resting periods. Resting was identified as a potentially determining factor for bone healing progression. Optimizing the ratio between stimulation and resting may contribute to more robust fracture healing in the future.