Emine Tuna Akdoğan

Emine Tuna Akdoğan

Auto-generated profile, based on publicly available information

Emine Tuna Akdoğan

Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Istanbul Kent University, Istanbul Türkiye

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 September 2026 in Current Medical Imaging
Verified
Journal Article
Closed access
PDF file
EAEmine Tuna Akdogan
Emine Tuna Akdogan
SCSinem Coşkun
Sinem Coşkun
NYNami Yeyin
Nami Yeyin
LULebriz Uslu-Besli
Lebriz Uslu-Besli
MDMustafa Demir
Mustafa Demir
Introduction/Objectives: Dental metal implants can generate artifacts in PET/CT imaging, particularly in the head and neck region, affecting quantitative accuracy. This study evaluated variations in standardized uptake value (SUV), contrast (C), and contrast-to-noise ratio (CNR) across predefined dental implant configurations differing in both implant number and spatial arrangement and assessed their effects on simulated tongue, nasopharyngeal, and laryngeal lesions. Methods: A custom-designed head and neck phantom containing extracted human teeth and up to eight titanium dental implants was used. Simulated tongue, nasopharyngeal, and laryngeal tumors were filled with F-18 FDG. PET/CT scans were acquired using seven implant configurations (0–8 implants) and reconstructed as attenuation-corrected (AC), AC with metal artifact reduction (AC+MAR), and non-attenuation-corrected (NoAC) images. SUV, contrast, and CNR were calculated using standardized ROIs. Results: Compared with the implant-free configuration, tongue tumor SUV decreased by 11% and 9.1% on AC and AC+MAR images, respectively, at eight implants. Nasopharyngeal and laryngeal SUV showed only minimal descriptive change with increasing implant number and configurations on AC+MAR images. Contrast and CNR followed similar trends on AC and AC+MAR images, whereas NoAC images consistently showed substantially lower contrast and CNR regardless of implant number. Discussion: Although MAR reduced implant-induced artifacts and partially attenuated SUV underestimation, it did not eliminate the configuration-dependent trend observed across the predefined implant arrangements. Lesions farther from the implants appeared less affected after MAR; however, this should be regarded as a hypothesis-generating observation from a single phantom experiment, requiring validation in patient studies and phantom models with varying implant-to-lesion distances. Conclusion: Dental implants may affect PET/CT quantification, particularly for lesions adjacent to multiple implants; SUV measurements in these regions should be interpreted with caution.

19 September 2022 in ADO Klinik Bilimler Dergisi
Verified
Journal Article
Closed access
MDMustafa Cenk Durmuşlar
Mustafa Cenk Durmuşlar
EAEmine Tuna Akdoğan
Emine Tuna Akdoğan
EGElif Aslı GÜLŞEN
Elif Aslı GÜLŞEN
Amaç; Bu retrospektif çalışmanın amacı temporomandibular eklem bozukluğu (TMD) şikâyeti ile kliniğe gelen ve daha önceden manyetik rezonans görüntülemesi (MRG) olan hastalarda klinik bulgular ve MRG bulguları arasındaki ilişkiyi değerlendirmektir. Gereç ve yöntem; Temporomandibular eklem bozukluğu (TMD) şikayeti ile gelen ve MR bulguları ve klinik muayene bulguları kaydedilmiş 85 hasta değerlendirildi. TME, MRG ve klinik muayene bulguları, çene ağrısı, ağız açıklığında kısıtlanma şikayetleri ve MR isteminin hangi bölüm tarafından yapıldığı retrospektif olarak değerlendirildi. Veriler SPSS 19 ile analiz edildi. Sayısal veriler ortalama ± standart sapma şeklinde sunuldu. Kategorik verilerin karşılaştırılmasında ki-kare testi kullanıldı. P<0.05 istatistiksel olarak önemli kabul edildi. Bulgular; Bu çalışmada 85 hastanın MRG sonuçları ve klinik bulguları retrospektif olarak incelendi. 85 hastanın 71’inin (%83,5) klinik ve MRG Bulguları arasında korelasyon bulundu. 14 hastanın (%16,5) bulguları uyumsuz bulundu. Sonuç; Çalışmanın sonuçlarında klinik muayene bulguları ile MRG bulguları arasında yüksek uyumluluk olduğu saptanmıştır. Konu hakkında daha yüksek hasta sayısı ve daha uzun süreli takibi olan araştırmalar yapılması önerilmektedir.

15 September 2026 in Essentials of Dentistry
Verified
Journal Article
Open access
PDF file
EAEmine Tuna Akdoğan
Emine Tuna Akdoğan
MDMustafa Demir
Mustafa Demir
Background: This study aimed to determine the radiation doses that may be received by dentists when examining or performing interventional procedures on patients who have undergone myocardial perfusion scintigraphy (MPS) for the evaluation of ischemic or scarred myocardial regions. Additionally, it sought to identify appropriate radiation protection measures from the perspective of dental practitioners. Methods: A total of 37 patients undergoing MPS were included in the study. Each patient received a cumulative activity of 1110 megabecquerels (MBq) of technetium 99m methoxy isobutyl isonitrile (Tc-99m MIBI) for stress and rest imaging. Following both stress and rest imaging, radiation dose rate measurements were obtained using a radiation detector from the neck, thoracic, and abdominopelvic regions at distances of 5 cm, 15 cm, 30 cm, 60 cm, and 100 cm within 0.5-3.0 hours after radiopharmaceutical administration. Results: The mean dose rates measured from the thoracic region at 5 cm, 15 cm, 30 cm, 60 cm, and 100 cm distances were 156.7 ± 23.5 μSv/h, 134.3 ± 23.2 μSv/h, 79.7 ± 29.6 μSv/h, 34.1 ± 17.6 μSv/h, and 15.1 ± 5.9 μSv/h, respectively. Conclusion: From a radiation safety perspective, it was determined that a patient who has undergone MPS can safely undergo dental examination and treatment at least 7 hours after imaging. For pregnant dental practitioners, a minimum waiting period of 10 hours is recommended to ensure radiological safety.

26 August 2026 in Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
Verified
Journal Article
Closed access
EAEmine Tuna Akdoğan
Emine Tuna Akdoğan
EPEnes Malik Pınarbaşı
Enes Malik Pınarbaşı
SCSinem Coşkun
Sinem Coşkun
NYNami Yeyin
Nami Yeyin
GAGhada Almisned
Ghada Almisned
MDMustafa Demir
Mustafa Demir

24 March 2026 in Meandros Medical and Dental Journal
Verified
Journal Article
Closed access
EAEmine Tuna Akdoğan
Emine Tuna Akdoğan
MDMustafa Demir
Mustafa Demir
Objective: This study aimed to determine the potential radiation doses to which dentists may be exposed when examining or performing interventional procedures on patients who have undergone technetium-99m methylene diphosphonate (⁹⁹ᵐTc-MDP) bone scintigraphy, primarily performed for the evaluation of bone malignancies. In addition, it sought to identify appropriate radiation protection measures from the perspective of dental practitioners. Materials and Methods: A total of 53 patients who underwent bone scintigraphy were included in this study. Each patient received an average of 925 megabecquerels (MBq) of ⁹⁹ᵐTc-MDP as a radiopharmaceutical. Two hours after administration, bone scintigraphy imaging was performed. Between 0.5 and 3 hours after imaging, radiation dose rate measurements were obtained from the head–neck, thoracic, and abdominopelvic regions using a radiation detector positioned at distances of 5 cm, 15 cm, 30 cm, 60 cm, and 100 cm. Results: The mean dose rates measured from the thoracic region at 5 cm, 15 cm, 30 cm, 60 cm, and 100 cm were 144.3 ± 36.9, 107.2 ± 16.9, 73.5 ± 13.8, 42.7 ± 10.0, and 12.5 ± 8.7 µSv/h, respectively. It was estimated that the daily exposure dose to a dentist would be below 4 µSv after approximately 10.4 hours of patient contact. Conclusion: If a patient who has undergone bone scintigraphy visits a dentist for examination or treatment 3 hours after imaging, the dentist’s radiation exposure would remain below the annual dose limit of 1 mSv. However, it was also determined that the 4 µSv/day exposure threshold could be reached after approximately 10.4 hours of close contact.