The primary cone-beam computed tomography (CBCT) imaging beam scatters inside the patient and produces a contaminating photon fluence that is registered by the detector. Scattered photons cause artifacts in the image reconstruction, and are partially responsible for the inferior image quality compared to diagnostic fan-beam CT. In this work, a deep convolutional autoencoder (DCAE) and projection-based scatter removal algorithm were constructed for the ImagingRing TM system on rails (IRr), which allows for non-isocentric acquisitions around virtual rotation centers with its independently rotatable source and detector arms. A Monte Carlo model was developed to simulate ( i ) a non-isocentric training dataset of ≈1200 projection pairs (primary + scatter) from 27 digital head-and-neck cancer patients around five different virtual rotation centers (DCAE NONISO ), and ( ii ) an isocentric dataset existing of ≈1200 projection pairs around the physical rotation center (DCAE ISO ). The scatter removal performance of both DCAE networks was investigated in two digital anthropomorphic phantom simulations and due to superior performance only the DCAE NONISO was applied on eight real patient acquisitions. Measures for the quantitative error, the signal-to-noise ratio, and the similarity were evaluated for two simulated digital head-and-neck patients, and the contrast-to-noise ratio (CNR) was investigated between muscle and adipose tissue in the real patient image reconstructions. Image quality metrics were compared between the uncorrected data, the currently implemented heuristic scatter correction data, and the DCAE corrected image reconstruction. The DCAE NONISO corrected image reconstructions of two digital patient simulations showed superior image quality metrics compared to the uncorrected and corrected image reconstructions using a heuristic scatter removal. The proposed DCAE NONISO scatter correction in this study was successfully demonstrated in real non-isocentric patient CBCT acquisitions and achieved statistically significant higher CNRs compared to the uncorrected or the heuristic corrected image data. This paper presents for the first time a projection-based scatter removal algorithm for isocentric and non-isocentric CBCT imaging using a deep convolutional autoencoder trained on Monte Carlo composed datasets. The algorithm was successfully applied to real patient data.

1 June 2018 in IEEE Transactions on Computational Imaging
Verified
Journal Article
Closed access
MTMika Takala
Mika Takala
DUDefne Us
Defne Us
SPSampsa Pursiainen
Sampsa Pursiainen
This study concentrates on advancing mathematical and computational methodology for radar tomography imaging in which the unknown volumetric velocity distribution of a wave within a bounded domain is to be reconstructed. Our goal is to enable effective simulation and inversion of a large amount of full-wave data within a realistic 2-D or 3-D geometry. For propagating and inverting the wave, we present a rigorous multigrid-based forward approach that utilizes the finite-difference time-domain method and a nested finite element grid structure. We also introduce and validate a multigrid-based inversion algorithm that allows regularization of the unknown distribution through a coarse-to-fine inversion scheme. Using this approach, sparse signals can be effectively inverted, as the coarse fluctuations are reconstructed before the finer ones. Furthermore, the number of nonzero entries in the system matrix can be compressed and, thus, the inversion procedure can be speeded up. As the test scenario, we investigate satellite-based asteroid interior reconstruction. We use both full-wave and projected wave data and estimate the accuracy of the inversion under different error sources: noise and positioning inaccuracies. The results suggest that the present inversion technique allows recovering the interior with a single satellite recording backscattering data. Robust results can be achieved, when the peak-to-peak signal-to-noise ratio is above 10 dB. Furthermore, the robustness for the deep interior part can be enhanced if two satellites can be utilized in the measurements.

5 December 2019 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
DUDefne Us
Defne Us
URUlla Ruotsalainen
Ulla Ruotsalainen
SPSampsa Pursiainen
Sampsa Pursiainen
Background: This paper investigates the benefits of data filtering via complex dual wavelet transform for metal artifact reduction (MAR). The advantage of using complex dual wavelet basis for MAR was studied on simulated dental computed tomography (CT) data for its efficiency in terms of noise suppression and removal of secondary artifacts. Dual-tree complex wavelet transform (DT-CWT) was selected due to its enhanced directional analysis of image details compared to the ordinary wavelet transform. DT-CWT was used for multiresolution decomposition within a modified total variation (TV) regularized inversion algorithm. Methods: In this study, we have tested the multiresolution TV (MRTV) approach with DT-CWT on a 2D polychromatic jaw phantom model with Gaussian and Poisson noise. High noise and sparse measurement settings were used to assess the performance of DT-CWT. The results were compared to the outcome of the single-resolution reconstruction and filtered back-projection (FBP) techniques as well as reconstructions with Haar wavelet basis. Results: The results indicate that filtering of wavelet coefficients with DT-CWT effectively removes the noise without introducing new artifacts after inpainting. Furthermore, adoption of multiple resolution levels yield to a more robust algorithm compared to varying the regularization strength. Conclusions: The multiresolution reconstruction with DT-CWT is also more robust when reconstructing the data with sparse projections compared to the single-resolution approach and Haar wavelets.

10 July 2018 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
DUDefne Us
Defne Us
KBKarol Brzezinski
Karol Brzezinski
TBTom Buitenhuis
Tom Buitenhuis
PDPeter Dendooven
Peter Dendooven
URUlla Ruotsalainen
Ulla Ruotsalainen
Dose delivery verification in proton beam radiotherapy is used to ensure the delivery of the dose to the correct location. A positron emission tomography (PET) scanner can be used to detect the secondary radiation during the treatment, so-called in-beam PET. This is a challenging application for PET due to the low counts and limited angular coverage. We propose a maximum a posteriori (MAP) reconstruction with median root prior (MRP) for the reconstruction of in-beam PET data. The proposed method was compared against MAP with total variation (TV) prior and maximum likelihood expectation maximization (MLEM), which have previously been used for this application. The effects of different ring configurations and time-of-flight information were tested with simulations of a geometrical phantom and a realistic patient treatment plan. The results indicate that both MAP methods produced sharper edges than MLEM, allowing more accurate edge localization in the reconstructed images. Even for the partial ring configurations, no elongation was observed with MAP methods. MAP-MRP successfully reduced the noise, whereas MAP-TV resulted in checkerboard artifacts. MAP-MRP was also more stable against the selection of the reconstruction parameters. In conclusion, MAP-MRP offers a simple and robust alternative for the reconstruction of in-beam PET data.