Ender Akan

Ender Akan

Auto-generated profile, based on publicly available information

Ender Akan

Department of Prosthodontics, Faculty of Dentistry, İzmir Katip Celebi University, İzmir, Turkey

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 May 2016 in Biotechnology & Biotechnological Equipment
Verified
Journal Article
Open access
ÖMÖzlem Malkondu
Özlem Malkondu
NTNeslihan Tinastepe
Neslihan Tinastepe
EAEnder Akan
Ender Akan
Ender KazazogluEnder Kazazoglu
Ender Kazazoglu
Zirconia restorations have been used successfully for years in dentistry owing to their biocompatibility and good mechanical properties. Because of their lack of translucency, zirconia cores are generally veneered with porcelain, which makes restorations weaker due to failure of the adhesion between the two materials. In recent years, all-ceramic zirconia restorations have been introduced in the dental sector with the intent to solve this problem. Besides the elimination of chipping, the reduced occlusal space requirement seems to be a clear advantage of monolithic zirconia restorations. However, scientific evidence is needed to recommend this relatively new application for clinical use. This mini-review discusses the current scientific literature on monolithic zirconia restorations. The results of in vitro studies suggested that monolithic zirconia may be the best choice for posterior fixed partial dentures in the presence of high occlusal loads and minimal occlusal restoration space. The results should be supported with much more in vitro and particularly in vivo studies to obtain a final conclusion.

6 May 2021 in Brazilian Journal of Otorhinolaryngology
Verified
Journal Article
Open access
OŞOnur Şahin
Onur Şahin
EAEnder Akan
Ender Akan
BTBirkan Tatar
Birkan Tatar
CECeren Ekmekcioğlu
Ceren Ekmekcioğlu
NÜNuri Ünal
Nuri Ünal
OOOnur Odabaşı
Onur Odabaşı
Increased incidence of localized osteonecrosis in the jaw bones caused by bisphosphanate use and reduced quality of life of the patients led researchers to diagnose the disease in the early period and to investigate the effective treatment modality. Treatment of medication-related osteonecrosis of the jaw patients is based on individual protocols from clinical experience, as there are no definitive treatment guidelines. In view of the lack of consensus on the effectiveness of medication-related osteonecrosis of the jaw treatments in the literature, the aim of this study was to evaluate the surgical technique described in the treatment of advanced stages of medication-related osteonecrosis of the jaw patients. Twenty-one patients affected by Stage 2-3 medication-related osteonecrosis of the jaw were treated with ultrasonic piezoelectric bone surgery for necrotic bone removing, leukocyte and platelet-rich fibrin concentrate obtained from the patient's peripheral blood and Nd:YAG laser for biostimulation. Success was assessed as the maintenance of full mucosal coverage without signs of residual infection at 1-month (T1), 3-months (T2), 6-months (T3) and 1-year (T4) after surgery. Logistic regressions were used to evaluate the association between the different independent variables and treatment outcomes. Two Stage 3 patients had delayed healing at 1 month after the operation. Complete mucosal healing was achieved in all patients at the third month. Multivariate analysis demonstrated that different variables were not significantly correlated with delayed healing (p > 0.05). The surgical protocol presented in this study shows promising results for surgical management of advanced stages of medication-related osteonecrosis of the jaw patients.

1 January 2019 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
AAAkın Aladağ
Akın Aladağ
DODidem Oğuz
Didem Oğuz
MÇMuharrem Erhan Çömlekoğlu
Muharrem Erhan Çömlekoğlu
EAEnder Akan
Ender Akan
Aladağ A, et al. J Adv Prosthodont. 2019 Apr;11(2):120-127. https://doi.org/10.4047/jap.2019.11.2.120

1 January 2014 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
HEHuseyin Ertas
Huseyin Ertas
ICIsmail Davut Capar
Ismail Davut Capar
HAHakan Arslan
Hakan Arslan
EAEnder Akan
Ender Akan
In recent years, with the advances in counterfeiting methods, counterfeit products have reached the dental market. The purpose of this study was to compare the cyclic fatigue resistance of original and counterfeit rotary root canal instruments. The cyclic fatigue of original and counterfeit ProTaper F2 endodontic instruments was tested (n = 20) in 3 mm radius steel canals with a 60° angle of curvature. The number of cycles to fracture (NCF) was calculated, and the data were subjected to the Student’s t-test (α = 0.05). The original instruments showed better cyclic fatigue resistance than the counterfeit ones (p < .001). The mean NCF was 483 ± 84 for the original files and 186 ± 86 for the counterfeit files. The cyclic fatigue resistance of the counterfeit instruments was very low. As a result, clinicians should be careful not to purchase counterfeit products.

1 January 2023 in Brazilian Oral Research
Verified
Journal Article
Open access
BKBegüm Ünlü Kurşun
Begüm Ünlü Kurşun
EAEnder Akan
Ender Akan
The objective of the study was to retrospectively compare the fractal size values calculated in the trabecular bone according to the type of complete removable denture, removable partial denture, and partial fixed prosthesis between patients using bisphosphonates and healthy patients, retrospectively. Panoramic radiographs of a total of 200 patients, (100 using bisphosphonates,100 control group), were taken from the right and left molar regions before and after treatment with 72 × 72 pixels. The fractal dimension (FD) was computed by using ImageJ Software using the box-counting method on the images obtained. There was an interaction effect between the trabecular bone change-patient group-the type of prosthesis used and the parameters of the area (p < 0.05). In patients using complete removable dentures and removable partial dentures in the maxilla and mandibula in the molar region, a greater decrease in FD values was observed in the control group than in the patient group using bisphosphonates. An increase in FD values over time was observed in the patient group using bisphosphonates with partial fixed maxillary and mandibular prostheses compared to the control group. Partial fixed prostheses should be preferred primarily instead of complete removable or removable partial dentures in patients using bisphosphonates to prevent osteonecrosis due to dental trauma.

23 February 2016 in Biotechnology & Biotechnological Equipment
Verified
Journal Article
Open access
EAEnder Akan
Ender Akan
Resin cements have the ability to bond to the tooth structure and to several indirect restorative materials and they are available in different transparency and shades. However, polymerization shrinkage remains to be a problem that leads to gap formation at the margins of restoration, and accordingly microleakage may occur. The purpose of this study was to investigate the influence of the shade of adhesive resin cement on its polymerization shrinkage. Five shades (Group 1: universal; Group 2: brown; Group 3: clear; Group 4: opaque white; Group 5: opaque yellow) of a dual-cure composite cement system (Clearfil Esthetic Cement, Kuraray, Tokyo, Japan) were studied with 10 specimens of each shade. Volumetric shrinkages of the composite cements of these five shades were evaluated using a video-imaging device (Acu-Vol; Bisco, Inc.) by measuring the volumes before and after polymerization. Different shades displayed different volumetric shrinkages. Group 5 (2.62%) and Group 2 (3.96%) displayed the lowest and highest shrinkage percentages, respectively, with their respective shrinkage values being significantly different from those of the other groups (p < 0.05). The obtained results indicate that the shade of resin cement does affect its degree of polymerization shrinkage.