Active electrocorticogram (ECoG) electrodes can amplify the weak electrophysiological signals and improve the anti-interference ability, but the traditional active electrodes are so opaque that cannot realize photoelectric collaborative observation. Here an active and fully-transparent ECoG array based on zinc oxide-thin film transistors (ZnO-TFTs) was developed as the local neural signal amplifier for electrophysiological monitoring. The transparency of the proposed ECoG array was up to 85% which is superior to previous reported active electrode array. Various electrical characterizations demonstrated its ability of electrophysiological signal recording, with a higher signal-to-noise ratio of 19.9 dB compared to the Au grid one (13.2 dB). The high transparency of ZnO-TFT electrode array allowed the collecting electrophysiological signals under direct light stimulation on optogenetic mice brain concurrently. The ECoG array could also work under 7-Tesla magnetic resonance imaging to record local brain signal without affecting brain tissue imaging. As the most transparent active ECoG array to date, it provides a powerful multimodal tool for brain observation, including recording brain activity under synchronized optical modulation and 7-Tesla magnetic resonance imaging.
1 December 2022 in American Journal of Neuroradiology
SUMMARY: The Monro-Kellie doctrine is a well-accepted principle of intracranial hemodynamics. It has undergone few consequential revisions since it was established. Its principle is straightforward: The combined volume of neuronal tissue, blood, and CSF is constant. To maintain homeostatic intracranial pressure, any increase or decrease in one of these elements leads to a reciprocal and opposite change in the others. The Monro-Kellie doctrine assumes a rigid, unadaptable calvaria. Recent studies have disproven this assumption. The skull expands and grows in response to pathologic changes in intracranial pressure. In this review, we outline what is known about calvarial changes in the setting of pressure dysregulation and suggest a revision to the Monro-Kellie doctrine that includes an adaptable skull as a fourth component.
25 June 2019 in Journal of NeuroInterventional Surgery
Background Clot perviousness in large vessel occlusion has been shown to be associated with improved recanalization outcomes with mechanical thrombectomy and intravenous thrombolysis. Objective To evaluate the association between clot perviousness based on thrombus attenuation increase (TAI) on CT, and histologic composition of clots in acute ischemic stroke (AIS). Methods A retrospective review was completed of patients with AIS secondary to large vessel occlusion, non-contrast CT (NCCT) and CT angiography (CTA) images, and histologic analysis of the retrieved clot. TAI was measured by subtracting clot attenuation on NCCT from the attenuation on CTA. Up to 3 regions of interest (ROIs) were evaluated on each clot; the average attenuation was used for analysis if multiple ROIs were assessed. Pervious clots were defined as TAI ≥10 Hounsfield units (HUs); impervious clots had TAI <10 HU. Histopathologic analyses of clots were assessed for relative compositions of red blood cells (RBCs), white blood cells (WBCs), fibrin, and platelets/other. Results 57 patients were included. Pervious clots were more likely to be RBC rich (p=0.04); impervious clots were more likely to be fibrin and WBC rich (p=0.01 for both). Pervious clots also had greater RBC density than impervious clots (49.8% and 33.0%, respectively; p=0.006); fibrin density of pervious clots was lower than that of impervious clots (17.8% and 23.2%, respectively; p=0.02). Conclusion Clot perviousness, assessed on NCCT and CTA imaging, is associated with higher RBC density and lower fibrin density, offering a possible explanation for the higher rates of successful thrombectomy and favorable clinical outcome seen in such patients.
19 December 2019 in American Journal of Neuroradiology
SUMMARY: Digital subtraction myelography is a valuable diagnostic technique to detect the exact location of CSF leaks in the spine to facilitate appropriate diagnosis and treatment of spontaneous spinal CSF leaks. Digital subtraction myelography is an excellent diagnostic tool for assessment of various types of CSF leaks, and lateral decubitus digital subtraction myelography is increasingly being used to diagnose CSF-venous fistulas. Lateral decubitus digital subtraction myelography differs from typical CT and fluoroscopy-guided myelograms in many ways, including equipment, supplies, and injection and image-acquisition techniques. Operators should be familiar with techniques, common pitfalls, and artifacts to improve diagnostic yield and prevent nondiagnostic examinations.
MRI of the inner auditory canal, middle ear, and labyrinth is complex and requires a detailed knowledge of the regional anatomy, the most common pathologic entities, and the expected postsurgical f... MRI is firmly established as an essential modality in the imaging of the temporal bone and lateral skull base. It is used to evaluate normal anatomic structures, evaluate for vestibular schwannomas...
SUMMARY: The management of acute ischemic stroke has undergone a paradigm shift in the past decade. This has been spearheaded by the emergence of endovascular thrombectomy, along with advances in medical therapy, imaging, and other facets of stroke care. Herein, we present an updated review of the various stroke trials that have impacted and continue to transform stroke management. It is critical for the radiologist to stay abreast of the ongoing developments to provide meaningful input and remain a useful part of the stroke team.