Sharon W. Gould

Sharon W. Gould

Auto-generated profile, based on publicly available information

Sharon W. Gould

Nemours Children’s Health, Wilmington, USA

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 August 2015 in Pediatric Radiology
Verified
Journal Article
Closed access
PDF file
SGSharon W. Gould
Sharon W. Gould
CRCynthia K. Rigsby
Cynthia K. Rigsby
LDLane F. Donnelly
Lane F. Donnelly
MMMichael McCulloch
Michael McCulloch
CPChristian Pizarro
Christian Pizarro
MEMonica Epelman
Monica Epelman

1 July 2012 in Journal of Pediatric Orthopaedics
Verified
Journal Article
Closed access
SGSharon W. Gould
Sharon W. Gould
LGLeslie E. Grissom
Leslie E. Grissom
ANAnastasia Niedzielski
Anastasia Niedzielski
HKHeidi H. Kecskemethy
Heidi H. Kecskemethy
JBJ. Richard Bowen
J. Richard Bowen
HHH. Theodore Harcke
H. Theodore Harcke
In reduction of hip displacement in developmental dysplasia, concentric placement of the femoral head within the acetabulum is key. Magnetic resonance imaging (MRI) is an effective modality to assess the adequacy of the reduction, but sedation may be required due to the length of the examination. MRI is also more expensive than other imaging modalities. Our goal was to provide an MRI protocol that does not require sedation and can be performed in <15 minutes. We retrospectively reviewed 34 consecutive MRI studies performed without sedation after spica cast placement in 24 developmental hip dysplasia patients. The MRI examinations were performed with a variety of techniques. Sequences used were evaluated for contrast, resolution, and motion artifact. Ninety-seven percent of studies were diagnostic, although 18% of examinations had significant motion artifact. Seven sequences were analyzed. T2-weighted fast spin echo sequences had the best overall scores and were performed in <3 minutes. T1 and fat-suppressed T2-weighted fast spin echo sequences did not score as well, and also required <3 minutes. Single-shot fast spin echo sequences scored poorly due to decreased contrast and resolution, despite shorter acquisition times of 20 to 40 seconds. Three-dimensional (3D) gradient recovery imaging scored poorly due to lower contrast and increased motion due to longer acquisition times of approximately 4 minutes. Both coronally and axially oriented sequences satisfactorily assessed femoral head position within the acetabulum. MRI is a useful tool in evaluating the hips without radiation exposure and without sedation in infants and toddlers after spica cast placement. Both axial and coronal T2 fast spin echo MRI sequences provided excellent anatomic definition and required ≤3 minutes per sequence. Orthopaedic surgeons can request these 2 sequences for accurate assessment of concentric reduction with a potential study time of 15 minutes, obviating the need for sedation. Level II.

14 June 2019 in Pediatric Radiology
Verified
Journal Article
Closed access
PDF file
SGSharon W. Gould
Sharon W. Gould
MHM. Patricia Harty
M. Patricia Harty
NGNicole E. Givler
Nicole E. Givler
TCTheresa E. Christensen
Theresa E. Christensen
RCRiley N. Curtin
Riley N. Curtin
HHHoward T. Harcke
Howard T. Harcke

29 March 2024 in Journal of Pediatric Surgery
Verified
Journal Article
Closed access
BSBeth Schwartz
Beth Schwartz
NWNimali Weerasooriya
Nimali Weerasooriya
RMRebecca Mercier
Rebecca Mercier
SGSharon Gould
Sharon Gould
DSDavid Saul
David Saul
LBLoren Berman
Loren Berman

1 August 2015 in Seminars in Ultrasound, CT and MRI
Verified
Journal Article
Closed access
SGSharon W. Gould
Sharon W. Gould
MEMonica Epelman
Monica Epelman

15 August 2022 in Journal of Pediatric Surgery
Verified
Journal Article
Closed access
BSBeth I. Schwartz
Beth I. Schwartz
RMRebecca Mercier
Rebecca Mercier
SGSharon Gould
Sharon Gould
DSDavid Saul
David Saul
CLClaire Loiselle
Claire Loiselle
LBLoren Berman
Loren Berman