Fulvia Arfelli

Fulvia Arfelli

Auto-generated profile, based on publicly available information

Fulvia Arfelli

Department of Physics, University of Trieste, 34127 Trieste, Italy

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 1997 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
DCD Chapman
D Chapman
WTW Thomlinson
W Thomlinson
RJR E Johnston
R E Johnston
DWD Washburn
D Washburn
EPE Pisano
E Pisano
DSD Sayers
D Sayers
Diffraction enhanced imaging is a new x-ray radiographic imaging modality using monochromatic x-rays from a synchrotron which produces images of thick absorbing objects that are almost completely free of scatter. They show dramatically improved contrast over standard imaging applied to the same phantom. The contrast is based not only on attenuation but also the refraction and diffraction properties of the sample. This imaging method may improve image quality for medical applications, industrial radiography for non-destructive testing and x-ray computed tomography.

1 April 2000 in Radiology
Verified
Journal Article
Closed access
FAFulvia Arfelli
Fulvia Arfelli
VBValter Bonvicini
Valter Bonvicini
ABAlberto Bravin
Alberto Bravin
GCGiovanni Cantatore
Giovanni Cantatore
ECEdoardo Castelli
Edoardo Castelli
FZFabrizio Zanconati
Fabrizio Zanconati
The authors evaluated the effect on mammographic examinations of the use of synchrotron radiation to detect phase-perturbation effects, which are higher than absorption effects for soft tissue in the energy range of 15-25 keV. Detection of phase-perturbation effects was possible because of the high degree of coherence of synchrotron radiation sources. Synchrotron radiation images were obtained of a mammographic phantom and in vitro breast tissue specimens and compared with conventional mammographic studies. On the basis of grades assigned by three reviewers, image quality of the former was considerably higher, and the delivered dose was fully compatible.

1 October 1998 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
FAF Arfelli
F Arfelli
MAM Assante
M Assante
VBV Bonvicini
V Bonvicini
ABA Bravin
A Bravin
GCG Cantatore
G Cantatore
FZF Zanconati
F Zanconati
Phase contrast x-ray imaging is a powerful technique for the detection of low-contrast details in weakly absorbing objects. This method is of possible relevance in the field of diagnostic radiology. In fact, imaging low-contrast details within soft tissue does not give satisfactory results in conventional x-ray absorption radiology, mammography being a typical example. Nevertheless, up to now all applications of the phase contrast technique, carried out on thin samples, have required radiation doses substantially higher than those delivered in conventional radiological examinations. To demonstrate the applicability of the method to mammography we produced phase contrast images of objects a few centimetres thick while delivering radiation doses lower than or comparable to doses needed in standard mammographic examinations (typically approximately 1 mGy mean glandular dose (MGD)). We show images of a custom mammographic phantom and of two specimens of human breast tissue obtained at the SYRMEP bending magnet beamline at Elettra, the Trieste synchrotron radiation facility. The introduction of an intensifier screen enabled us to obtain phase contrast images of these thick samples with radiation doses comparable to those used in mammography. Low absorbing details such as 50 microm thick nylon wires or thin calcium deposits (approximately 50 microm) within breast tissue, invisible with conventional techniques, are detected by means of the proposed method. We also find that the use of a bending magnet radiation source relaxes the previously reported requirements on source size for phase contrast imaging. Finally, the consistency of the results has been checked by theoretical simulations carried out for the purposes of this experiment.

9 August 2001 in Medical Physics
Verified
Journal Article
Closed access
AOAlessandro Olivo
Alessandro Olivo
FAF. Arfelli
F. Arfelli
GCG. Cantatore
G. Cantatore
RLR. Longo
R. Longo
RMRalf Hendrik Menk
Ralf Hendrik Menk
ECE. Castelli
E. Castelli

1 June 2011 in Radiology
Verified
Journal Article
Closed access
ECEdoardo Castelli
Edoardo Castelli
MTMaura Tonutti
Maura Tonutti
FAFulvia Arfelli
Fulvia Arfelli
RLRenata Longo
Renata Longo
Emilio QuaiaEmilio Quaia
Emilio Quaia
MCMaria Assunta Cova
Maria Assunta Cova
To prospectively evaluate the diagnostic contribution of mammography with synchrotron radiation in patients with questionable or suspicious breast abnormalities identified at combined digital mammography (DM) and ultrasonography (US). The ethics committee approved this prospective study, and written informed consent was obtained from all patients. Mammography with synchrotron radiation was performed with a phase-detection technique at a synchrotron radiation laboratory. Forty-nine women who met at least one of the inclusion criteria (palpable mass, focal asymmetry, architectural distortion, or equivocal or suspicious mass at DM; none clarified at US) were enrolled. Forty-seven women (mean age, 57.8 years ± 8.8 [standard deviation]; age range, 43-78 years) completed the study protocol, which involved biopsy or follow-up for 1 year as the reference standard. Breast Imaging Reporting and Data System (BI-RADS) scores of 1-3 were considered to indicate a negative result, while scores 4-5 were considered to indicate a positive result. The visibility of breast abnormalities and the glandular parenchymal structure at DM and at mammography with synchrotron radiation was compared by using the Wilcoxon signed rank test. In 29 of the 31 patients with a final diagnosis of benign entity, mammography with synchrotron radiation yielded BI-RADS scores of 1-3. In 13 of the remaining 16 patients with a final diagnosis of malignancy, mammography with synchrotron radiation yielded BI-RADS scores of 4-5. Therefore, a sensitivity of 81% (13 of 16 patients) and a specificity of 94% (29 of 31 patients) were achieved with use of the described BI-RADS dichotomization system. These study results suggest that mammography with synchrotron radiation can be used to clarify cases of questionable or suspicious breast abnormalities identified at DM. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11100745/-/DC1.

29 April 2003 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
LRLuigi Rigon
Luigi Rigon
HBHans-Juergen Besch
Hans-Juergen Besch
FAFulvia Arfelli
Fulvia Arfelli
RMRalf Hendrik Menk
Ralf Hendrik Menk
GHGabriele Heitner
Gabriele Heitner
HPHartmute Plothow-Besch
Hartmute Plothow-Besch